Registers refreshed 2026-11-20.See refresh dates
United States

CTA Acoustics,

100 CTA BLVD, 40701, Corbin, KY, United States

Visit website
A2LA 6779.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
16
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 16 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM9
ASTM C522
ASTM D737
ASTM D896
ASTM D903
ASTM D2261
ASTM D3767
ASTM D5034
ASTM D5587
ASTM E1530
ISO6
ISO 37Rubber, vulcanized or thermoplastic - Determination of tensile stress-strain properties
ISO 188Rubber, vulcanized or thermoplastic - Accelerated ageing and heat resistance tests
ISO 1856Flexible cellular polymeric materials - Determination of compression set
ISO 1923Cellular plastics and rubbers - Determination of linear dimensions
ISO 3795Road vehicles, and tractors and machinery for agriculture and forestry - Determination of burning behaviour of interior materials
ISO 8510-2Adhesives - Peel test for a flexible-bonded-to-rigid test specimen assembly - Part 2: 180° peel
Other standards1
DIN 75200

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

6779.01

The scope document we hold says it is valid until 2026-12-31.

View scope

Accredited scope, certificate 6779.01

LineMethodMatrixRange
1FLTM BO 040-01 Procedure A; FLTM BO 040-01 Procedure B; GMW14124 Cycle R; GMW14194; FCA LP-463CB-10-01-A; NES M0132 Method 3 Class 2; NES M0132 Method 4 Class 2; DWG 7425Z-SNA-0000; DWG 7414Z-SNA-0000; GMW14194; RNDS-C-00373; ISO 188; FCA LP-463LB-13-01; MS-HZ-100; GMW 15725; DWG 7425Z-SNA-0000; DWG 7414Z-SNA-0000; DWG 7414Z-SNA-0000; FLTM BN 102-01 procedure Aautomotive acoustic and trim products located in the Interior, Trunk, Powertrain, and Exterior of the vehicle-
2WSS-M99P32-E6; WSS-M99P32-E1; MS-HZ-100; GMW 3259; FLTM BO 131-03; ASTM D5034; ASTM D903; ISO 37; NES M 0076 Item 12; HES D6507 Item 4.4; HES D6507 Item 4.5.2; FLTM BN 151-05; ASTM D903; HES D6507 Item 4.6; D41-1015; ISO 8510-2; ASTM D2261; ASTM D5587; NES M 0076 Item 13; DWG 7425Z-SNA-0000; DWG 7414Z-SNA-0000; GMW14695; GMW14194; ASTM E1530; ISO 3795; GMW3232; SAE J369; NES M0094; DIN 75200--
3ASTM D3767; ISO 1923; NES M 0076; WSS-M99P32-E6; WSS-M99P32-E1; FLTM BN 106-1; ASTM D896; GMW14194; GMW14334; GMW15725; NES M0133; MS-HZ-100; NDS 65840NDS00; NES M0076; NDS 67800NDS00; TL 52094-K--
4ISO 1856 Method A; GMW16998; ASTM C522; ASTM D737Dust; Air-
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited CTA ACOUSTICS, INC. Corbin, Kentucky for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 18th day of October 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6779.01 Valid to December 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

100 CTA BLVD, Corbin, KY, 40701, US

36.94870, -84.09688

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.