What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO5
ISO 5579Non-destructive testing - Radiographic testing of metallic materials using film and X- or gamma rays - Basic rules
ISO 9934-1Non-destructive testing - Magnetic particle testing - Part 1: General principles
ISO 17636-1Non-destructive testing of welds - Radiographic testing - Part 1: X- and gamma-ray techniques with film
ISO 17638Non-destructive testing of welds - Magnetic particle testing
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment
EN4
EN 571-1
EN 1369Founding - Magnetic particle testing
EN 10160Ultrasonic testing of steel flat product of thickness equal to or greater than 6 mm (reflection method)
EN 12681-1
EN 10228 series4
EN 10228-1Non-destructive testing of steel forgings - Part 1: Magnetic particle inspection
EN 10228-2Non-destructive testing of steel forgings - Part 2: Penetrant testing
EN 10228-3Non-destructive testing of steel forgings - Part 3: Ultrasonic testing of ferritic or martensitic steel forgings
EN 10228-4Non-destructive testing of steel forgings - Part 4: Ultrasonic testing of austenitic and austenitic-ferritic stainless steel forgings
DIN EN ISO 5579; DIN EN ISO 17636-1; DIN EN 12681-1; DIN EN ISO 9934-1; DIN EN ISO 17638; DIN EN 1369; DIN EN 10228-1; DIN EN 571-1; DIN EN 10228-2
DIN EN ISO 17640; DIN EN 10160; DIN EN 10228-3; DIN EN 10228-4; SEP 1921; AD 2000-Merkblatt HP 5/3 Anlage 1
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
3 lines
ISO/IEC 17025
ActiveD-PL-11099-01-00
Accredited scope, certificate D-PL-11099-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Metal | - |
| 2 | DIN EN ISO 5579; DIN EN ISO 17636-1; DIN EN 12681-1; DIN EN ISO 9934-1; DIN EN ISO 17638; DIN EN 1369; DIN EN 10228-1; DIN EN 571-1; DIN EN 10228-2 | Metal | - |
| 3 | DIN EN ISO 17640; DIN EN 10160; DIN EN 10228-3; DIN EN 10228-4; SEP 1921; AD 2000-Merkblatt HP 5/3 Anlage 1 | Schweißverbindungen; Flacherzeugnissen aus Stahl; Schmiedestücken aus Stahl; Schmiedestücken und geschmiedetem Stabstahl | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- GWQ GmbH & Co.KGMoers · ~199 kmDAKKSShares 4 accredited methods and materialsEN ISO 17638EN ISO 17640EN ISO 9001
- ZEROSBerlin · ~302 kmDAKKSShares 4 accredited methods and materialsEN ISO 17638EN ISO 17640EN ISO 9001
- Metal CheckBurgkirchen a.d.Alz · ~422 kmDAKKSShares 4 accredited methods and materialsEN ISO 17638EN ISO 17640EN ISO 9001
- WOITT Inspection Service GmbH & Co. KGSulingen · ~156 kmDAKKSShares 3 accredited methods and materialsEN ISO 17640EN ISO 9001Metal
- WPW Werkstoff-Prüfung WieczorekHaltern am See · ~166 kmDAKKSShares 3 accredited methods and materialsEN ISO 17638EN ISO 9001Metal
Accreditation data refreshed from the DAKKS register on .