KEMA-Powertest
4379 County Line Road, 18914, Chalfont, PA, United States
- Accredited standards
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60099-4
IEC 60502-4
IEC 62271-111Some clauses
Limits written next to it
IEC 62271-111, 2019, sub-clause 7.101.4.3
IEC 62271-111, 2019, sub-clause 7.101.4.4
IEC 62271-111, 2019, sub-clause 7.6
IEC 62271-111, 2019 sub-clause 7.2.7.2
IEC 62271-111, 2019, sub-clause 7.102
IEC 62271-111, 2019, sub-clause 7.2.7.3
IEC 62271-111, 2019, sub-clause 7.5
IEC 62271-111, 2019, sub-clause 7.103
IEC 62271-200Some clauses
Limits written next to it
IEC 62271-200, 2021, sub-clause 7.6
IEC 62271-200, 2021, sub-clause 7.2.7.2
IEC 62271-200, 2021, sub-clause 7.2.7.3
IEC 62271-200, 2021, sub-clause 7.5
IEC 62271-200, 2021, sub-clause 7.4
Internal Arc Test IEC 62271-200, 2021, sub-clause 7.105
IEEE Std C37.74-2014; IEEE Std C37.60-2018; IEC 62271-111; IEEE Std C37.09-2018; IEEE Std C37.41-2016; IEEE C37.66-2021; IEEE Std C57.15-2017; IEC 62271-200; IEEE C62.11-2020; IEC 60099-4; IEC 60502-4; CENELEC HD 629-1-S3
IEEE Std 1247-2005; IEEE Std C37.74-2014; IEEE Std C37.09-2018; IEEE Std C37.60-2018; IEC 62271-111; IEC 60502-4; CENELEC HD 629-1-S3; IEEE Std C57.16-2011; IEEE Std C57.15-2017; IEC 62271-200; ISO/IEC 17025:2017
IEEE Std 1247-2005; IEEE Std C37.74-2014; IEEE Std C37.60-2018; IEC 62271-111; IEEE C37.66-2021; IEC 60502-4; CENELEC HD 629-1-S3; IEEE Std C37.09-2018; IEEE Std C57.16-2011; IEEE Std C57.15-2017; IEC 62271-200
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active553.01
The scope document we hold says it is valid until 2026-12-31.
Accredited scope, certificate 553.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEEE Std 1247-2005; IEEE Std C37.74-2014; IEEE Std C37.09-2018; IEEE Std C37.60-2018; IEC 62271-111; IEC 60502-4; CENELEC HD 629-1-S3; IEEE Std C57.16-2011; IEEE Std C57.15-2017; IEC 62271-200; ISO/IEC 17025:2017 | circuit breakers; transformers; switches; switchgear; fuses; surge suppressors; MCCs; reactors; related electrical power equipment | - |
| 2 | IEEE Std 1247-2005; IEEE Std C37.74-2014; IEEE Std C37.60-2018; IEC 62271-111; IEEE C37.66-2021; IEC 60502-4; CENELEC HD 629-1-S3; IEEE Std C37.09-2018; IEEE Std C57.16-2011; IEEE Std C57.15-2017; IEC 62271-200 | - | - |
| 3 | IEEE Std C37.74-2014; IEEE Std C37.60-2018; IEC 62271-111; IEEE Std C37.09-2018; IEEE Std C37.41-2016; IEEE C37.66-2021; IEEE Std C57.15-2017; IEC 62271-200; IEEE C62.11-2020; IEC 60099-4; IEC 60502-4; CENELEC HD 629-1-S3 | - | 0 to 900 kV |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
`
Accredited Laboratory
A2LA has accredited
KEMA-POWERTEST LLC
Chalfont, PA
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 4th day of April 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0553.01
Valid to December 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.