Ricardo Certification
Daalsesingel 51, 3511 SB, UTRECHT, Netherlands
- Accredited standards
- 1
- RvA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the RvA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 50121-3-1
EN 50121-3-1
Read from the RvA scope document we downloaded on 2026-09-20. Register refreshed 2026-10-25.
Scope as published by RvA
2 lines
ISO/IEC 17025
ActiveL450
The scope document we hold says it is valid until 2030-05-01.
Accredited scope, certificate L450
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Eigen methode | Hoog- en laagspanningscircuits van spoorwegsystemen (spoorwegmaterieel en spoorweginfrastructuur) | -4500 to 4500 V |
| 2 | EN 50121-3-1 | Hoog- en laagspanningscircuits van spoorwegsystemen (spoorwegmaterieel en spoorweginfrastructuur); Spoorwegsystemen; Spoorwegsystemen: Rollend Materieel | -6000 to 6000 A |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the RvA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.