TCM Company
3561 Haven Ave, 94025, Menlo Park, CA, United States
- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 6996.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6996.01) 3/3/2026 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
TCM COMPANY LLC
3561 Haven Ave
Menlo Park, CA 94025
Tim Markley Phone: 650 593 8448
CALIBRATION
Valid To: April 30, 2028 Certificate Number: 6996.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Electrical – DC / Low Frequency
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicators3 –
Generate
Type J
Type K
Type S
(0 to 250) °F
(250 to 500) °F
(500 to 750) °F
(750 to 1000) °F
(1000 to 1250) °F
(0 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 2000) °F
(2000 to 2400) °F
(100 to 650) °F
(650 to 1300) °F
(1300 to 1950) °F
(1950 to 2600) °F
(2600 to 3200) °F
0.65 °F
0.62 °F
0.64 °F
0.70 °F
0.70 °F
1.1 °F
0.86 °F
1.1 °F
1.1 °F
1.1 °F
2.4 °F
2.1 °F
2.1 °F
2.3 °F
2.3 °F
Fluke 741B/743B | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6996.01) 3/3/2026 Page 2 of 4
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicators3 –
Measure
Type K:
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
2.3 °F
2.3 °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.3 °F
2.2 °F
2.3 °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.6 °F
2.7 °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.3 °F
2.3 °F
2.4 °F
2.6 °F
2.7 °F
2.7 °F
2.4 °F
2.4 °F
2.3 °F
2.5 °F
2.5 °F
2.4 °F
2.3 °F
2.4 °F
2.3 °F
2.3 °F
Honeywell Minitrend | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6996.01) 3/3/2026 Page 3 of 4
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicators3 (cont) –
Measure
Type K:
Channel 8
Channel 9
Channel 10
Channel 11
Channel 12
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
(100 to 500) °F
(500 to 1000) °F
(1000 to 1500) °F
(1500 to 1900) °F
(1900 to 2300) °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.4 °F
2.4 °F
2.3 °F
2.2 °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.4 °F
2.4 °F
2.4 °F
2.3 °F
2.3 °F
2.3 °F
2.4 °F
2.5 °F
2.2 °F
2.3 °F
2.3 °F
2.3 °F
2.3 °F
Honeywell Minitrend
______________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6996.01) 3/3/2026 Page 4 of 4
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.