Poland
ELPOLAB Sp. z o.o.
Zawada 26, 28-230, Połaniec, Poland
PCA|AB 743ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
5
Locations
1
Contact this laboratory
Register record
- PCACollected
- AB 743Active
Certificates and scope
1PCA
ISO/IEC 17025
ActiveAB 743
Accredited scope, certificate AB 743
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | PN-G-04611:2020-06; PN-ISO 589:2006 Metoda A1; PN-ISO 1171:2002; PN-G-04584:2001; ISO 19579:2006; PN-G-04571:1998; PN-81/G-04513; PN-ISO 1928:2020-05; PN-G-04516:1998; PN-G-04560:1998 | Coal | 0.3 to 33000 % ; kJ/kg |
| chemical | PB-02 wydanie E z dnia 2019-01-08; PN-G-04502:2014-11; PN-G-04571:1998; PN-EN ISO 18134-2:2024-10; PN-EN ISO 18134-3:2023-12; PN-EN ISO 18122:2023-05; PN-EN ISO 18125:2017-07; PN-EN ISO 16994:2016-10; PN-EN ISO 16948:2015-07; PN-EN ISO 21644:2021-07; PN-EN ISO 18135:2017-06 | Coal | 0.5 to 99 % |
| chemical | PN-EN ISO 21660-3:2021-08; PN-EN ISO 21656:2021-08; PN-EN ISO 21644:2021-07; PB-10 wydanie B z dnia 2021-12-10 | stałe paliwa wtórne; Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80; popiół lotny do betonu | 1 to 95 %; Bq/kg |
| chemical | - | Drinking water | - |
| chemical | PN-EN 27888:1999; PN-EN ISO 10523:2012; PN-EN 872:2007+Ap1:2007; PN-EN 15216:2022-03; PN-ISO 15705:2005; PN-EN ISO 11885:2009; PN-EN ISO 10304-1:2009+AC:2012; PN-ISO 5667-5:2017-10; PN-EN ISO 5667-6:2016-12; PN-77/C-04584; PN-ISO 5667-10:2021-11 | Drinking water | -0.5 to 30000 ºC; mS/cm; mg/l; μg/l |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Poland
- SGS Polska Sp. z o.o.Pszczyna · ~174 kmPCAShares 4 accredited methods and materialsISO 1171:2002PN-G-04571:1998Coal
- Centralne Laboratorium Pomiarowo-BadawczeJastrzębie Zdrój · ~198 kmPCAShares 3 accredited methods and materialsISO 1171:2002CoalDrinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~56 kmPCAShares 2 accredited methods and materialsEN 27888:1999Drinking water
- Ferrocarbo Sp. z o.o.Kraków · ~104 kmPCAShares 2 accredited methods and materialsPN-G-04571:1998Coal
- Marley Laboratorium Sp. z o.o.Siemianowice Śląskie · ~161 kmPCAShares 2 accredited methods and materialsISO 1171:2002Coal
Accreditation data collected from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.