Miejskie Przedsiębiorstwo Wodociągów i Kanalizacji Sp. z o.o. w Lubinie
ul. Zielona 2, 59-300, Lubin, Poland
- Accredited standards
- 8
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
PN-ISO 5667-10:2021-11; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002; PN-ISO 15705:2005; PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010; PN-EN 872:2007 + Ap1:2007; PN-82/C-04576/08; PN-EN 26777:1999; PN-EN 25663:2001; PN-73/C-04576/14
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
2 lines
ISO/IEC 17025
ActiveAB 1724
The scope document we hold says it is valid until 2027-08-18.
Accredited scope, certificate AB 1724
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Waste waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1724
Scope of accreditation No. AB 1724
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1724
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 6 z/of 19.07.2023
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr A B 1724 z dnia 25.11.2019 r.
Cykl akredytacji od 19.07.2023 r. do 18.08.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1724 of 25.11.2019
Accreditation cycle from 19.07.2023 to 18.08.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 6, 19.07.2023 1/3
Nazwa i adres / Name and address
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW
I KANALIZACJI Sp. z o. o. w Lubinie
ul. Rzeźnicza 1
59-300 Lubin
LABORATORIUM
ul. Zielona 2
59-300 Lubin
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/30/P - Badania chemiczne i pobieranie próbek ścieków / Chemical tests and sampling of sewage
- N/30/P - Badania właściwości fizycznych i pobieranie próbek ścieków / Tests of physical properties and
sampling of sewage
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1724 | - |
| 2 | PN-ISO 5667-10:2021-11; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002; PN-ISO 15705:2005; PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010; PN-EN 872:2007 + Ap1:2007; PN-82/C-04576/08; PN-EN 26777:1999; PN-EN 25663:2001; PN-73/C-04576/14 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Centrum Badań Jakości Spółka z ograniczoną odpowiedzialnościąLubin · under 1 kmPCAShares 2 accredited methods and materialsISO 5667-10:2021-11Waste water
- LabAnalitykaBrzeg Dolny · ~38 kmPCAShares 2 accredited methods and materialsISO 5667-10:2021-11Waste water
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~197 kmPCAShares 2 accredited methods and materialsISO 5667-10:2021-11Waste water
- "Energopomiar"Gliwice · ~212 kmPCAShares 2 accredited methods and materialsISO 5667-10:2021-11Waste water
- Zakład Usług Technicznych "ZUT" S.C. Bożena i Waldemar SzleperCzęstochowa · ~215 kmPCAShares 2 accredited methods and materialsISO 5667-10:2021-11Waste water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.