What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 20 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM12
ASTM C738
ASTM C927
ASTM D1230
ASTM D1777
ASTM D6988
ASTM F963
ASTM F2057
ASTM F2058
ASTM F2601
ASTM F2617
ASTM F2853
ASTM F2923
IEC 62321 series7
IEC 62321-3-1
IEC 62321-4
IEC 62321-5
IEC 62321-6
IEC 62321-7-1
IEC 62321-7-2
IEC 62321-8
Other standards1
EN 71Safety of toys
IEC 62321-7-1; IEC 62321-7-2; IEC 62321-8; ASTM F2617-15; CPSC-CH-C1001-09.3; CPSC-CH-C1001-09.4; CPSC-CH-E1004-11; ASTM F2923-20; EN 71 (Part 3); 21 CFR Part 175.300(e); 21 CFR 177.1210(c); 21 CFR 177.1500(d); 21 CFR 177.1520(d); 21 CFR Part 177.2600(e)&(f); ASTM C738-94; ASTM C927-80
16 CFR 1500.51(f); 16 CFR 1500.52(f); 16 CFR 1500.53(f); ASTM F963-23; 16 CFR 1500.51(g); 16 CFR 1500.52(g); 16 CFR 1500.53(g); 16 CFR 1500.51(d); 16 CFR 1500.52(d); 16 CFR 1500.53(d); 16 CFR 1500.14(b)(8); 15 CFR 1150; 16 CFR 1500.18(a)(17); 16 CFR 1500.19; ASTM F2923; 16 CFR 1610; ASTM D1230; CAN/CGSB-4.2 No. 27.5; 16 CFR 1500.44
ASTM F2601; ASTM F2058; ASTM D1777; ASTM F963-23
ASTM F963-23; ASTM D6988-08; 16 CFR 1500.51(b); 16 CFR 1500.52(b); 16 CFR 1500.53(b); 16 CFR 1500.51(e); 16 CFR 1500.52(e); 16 CFR 1500.53(e)
16 CFR 1303; CPSC-CH-E1003-09.1; ASTM F2853-10; ASTM F963-23; CPSC-CH-E1001-08.3; CPSC-CH-E1002-08.3; IEC 62321:2008-12; IEC 62321-3-1; IEC 62321-4; IEC 62321-5; IEC 62321-6
ASTM F2057; 16 CFR 1261; EN 71 (Part 1); EN 71 (Part 2); 16 CFR 1501; ASTM F963-23; 16 CFR 1500.48; 16 CFR 1500.49; 16 CFR 1510; 16 CFR 1511; 16 CFR 1500.18(a) (19); 1500.86(a) (7); 1500.86(a) (8)
Read from the A2LA scope documents we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active3331.09
The scope document we hold says it is valid until 2027-06-30.
ISO/IEC 17025
Active3331.10
The scope document we hold says it is valid until 2027-06-30.