Registers refreshed 2026-11-08.See refresh dates
Germany

Funkwerk Systems GmbH

Im Funkwerk 5, 99625, Kölleda, Germany

DAKKS D-PL-20557-01-00DAKKS D-PL-20557-01-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
9
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI TS 102 933-1
ETSI TS 102 933-2
ETSI TS 151 010-1
ETSI TS 151 010-2
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

5 lines
DAKKS

ISO/IEC 17025

Active

D-PL-20557-01-00

Accredited scope, certificate D-PL-20557-01-00

No scope items available

DAKKS

ISO/IEC 17025

Active

D-PL-20557-01-01

View scope

Accredited scope, certificate D-PL-20557-01-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2

Extracted from the scope document; tables may not line up. View scope for the original.

Annex to the Accreditation Certificate D-PL-20557-01-01 Valid from : 11.12.2025 Date of issue : 11.12.2025 page 2 of 5 This document is a translation. The definitive version is the original German annex to the accreditation certificate. Flexible Scope of Accreditation: Within the indicated test areas the testing laboratory is permitted without being required to prior inform and obtain approval from DAkkS [Flex A] to use standardised or equivalent test met hods listed here with different issue dates. The test methods listed are examples. The testing laboratory has an up-to-date list of all test methods within the flexible scope of accreditation. The list is publicly available on the website of the testing laboratory Content 1 Mobile Communication [Flex A] ................... ..................................................................................... 3 2 Telecommunication Railway Systems [Flex A] ...... ............................................................................ 3 3 Telecommunication Railway Systems ............... ................................................................................ 4 4 Environmental Tests [Flex A] .................... ......................................................................................... 5
33GPP TS 51.010 -1; ETSI TS 151 010-1; 3GPP TS 51.010 -2; ETSI TS 151 010-2; ETSI EN 301 511; ETSI TS 102 933 -1; ETSI TS 102 933 -2; EIRENE SRS; O-3001 Rev. 1.5.0; Add-On O-3001Mobile Station (MS); Mobile Communication; Railway Telecommunications (RT); GSM -R; Telecommunication Railway Systems-
4UIC Project EIRENE System Requirements Specification Standard test procedure - O-3001 Part 1 – Cab Radio, Version 1.0.0, July 2017; UIC Project EIRENE System Requirements Specification Standard test procedure - O-3001 Part 2 – EDOR, Version 1.0.0 July 2017; UIC Project EIRENE System Requirements Specification Standard test procedure - O-3001 Part 3 – SIM cards, Version 1.0.0 July 2017; UIC Project EIRENE System Requirements Specification Standard test procedure - O-3001 Part 4 – Network, Version 1.1.0, Nov. 2017; In-house procedure – Add-On O-3001 Version 8.0, 28.04.2016; UIC Project EIRENE System Requirements Specification Standard-Test-Procedure - O-3001 Part 1 – Cab Radio, Version 1.0.0, July 2017; UIC Project EIRENE System Requirements Specification Standard-Test-Procedure - O-3001 Part 2 – EDOR, Version 1.0.0 July 2017; UIC Project EIRENE System Requirements Specification Standard-Test-Procedure - O-3001 Part 3 – SIM cards, Version 1.0.0 July 2017; UIC Project EIRENE System Requirements Specification Standard-Test-Procedure - O-3001 Part 4 – Network, Version 1.1.0, Nov. 2017; In-house procedure – Add-On O-3001 Version 8.0, 28.04.2016; UIC O -2475 Version 3.0 19.02.2007; UIC O -2875 Version 2.0 23.11.2021; UIC Code 751 -3, 4. Issue, July 2005; Test hand book ATR Germany Austria Version 6.0 26.03.2020; UIC Code 568, 3. Issue , 01.01.1996; Test hand book ATR Germany Austria Version 6.0 26.03.2020Cab Radio; EDOR; SIM cards; Network; ERTMS / GSM-R Quality of Service; ERTMS / GSM-R Quality of Service for (MI) EIRENE QoS requirements Voice and non-ETCS data; ATR Germany Austria-
5DIN EN 60068-2-1; DIN EN 60068-2-2; DIN EN 60068-2-14; DIN EN 60068-2-30--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Im Funkwerk 5, Kölleda, 99625, DE

51.19579, 11.20484

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.