Aalberts IPSA

1418 S. Pearl Street, 29728, Pageland, SC, United States

Visit website
A2LA 1736.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 1736.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017 AND ANSI/NCSL Z540-1-1994; IEC 17025; ANSI/NCSL Z540-1-1994-to 10 in
2ison Calipers Up to 20-to 30 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1736.01) 4/2/2025 Page 3 of 3 Parameter/Equipment Range CMC2, 3 (±) Comments Indicators Up to 4 in 0.60R Universal measuring machine II. Mechanical Parameter/Equipment Range CMC2 (±) Comments Torque Wrenches & Torque Multipliers (0.5 to 400) ozf·in (4 to 1000) lbf·in (20 to 250) lbf·ft (100 to 1100) lbf·ft 2.8 ozf·in 2.9 lbf·in 2.4 lbf·ft 4.1 lbf·ft CDI torque tester Pressure Gages Up to 300 psig Up to 10 000 psig Up to 15 000 psig Up to 3000 psig Up to 3000 psig Up to 10 000 psig Up to 15 000 psig 0.1 psig 2.5 psig 3.9 psig 0.6 psig 1.2 psig 2.9 psig 7.1 psig Crystal digital test gage Pace 5000 Comparator ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, D is the numerical value of the diameter of the device measured in inches, and R is the numerical value of the resolution of the device. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1418 S. Pearl Street, Pageland, SC, 29728, US

34.75209, -80.39246

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.