United States

Atlas Material Testing Technology

1500 Bishop Court, 60056, Mount Prospect, IL, United States

Visit website
A2LA 2101.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM G179
ISO 4892-1Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance and requirements

Read from the scope as published by A2LA. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

2101.01

View scope

Accredited scope, certificate 2101.01

LineMethodMatrixRange
1ISO/IEC 17025:2017-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2101.01) 9/24/2025 Page 2 of 6 Parameter/Equipment Range CMC2, 7 (±) Comments6 Location11 Illuminance3, 4 (With Xenocal) – SUNTEST Instruments (380 to 780) nm Xenotest Instruments (380 to 780) nm Up to 240 klx Up to 240 klx 4.9 % 7.5 % 10 % 4.5 % Daylight, SolarStandard, WG, StoreLight, ID65 XC270, XC300, B04 XC320, XC320HLF, 7IR, 16H, 4IR3WG, 6IR1UV, GMW3414 10WG, TM16, DL Ext. IR WIN Irradiance3, 4 (With Xenocal) – SUNTEST Instruments: 340 nm – Spectral 420 nm – Spectral (300 to 400) nm (300 to 800) nm (300 to 400) nm (300 to 800) nm Xenotest Instruments: 340 nm – Spectral 420 nm – Spectral (300 to 400) nm (300 to 800) nm (300 to 400) nm (300 to 800) nm (300 to 400) nm (300 to 800) nm (300 to 400) nm (300 to 800) nm Up to 1.4 W∙m -2∙nm-1 Up to 3.5 W∙m-2∙nm-1 Up to 150 W∙m-2 Up to 1300 W∙m-2 Up to 150 W∙m -2 Up to 1300 W∙m-2 Up to 1.4 W∙m -2∙nm-1 Up to 3.5 W∙m-2∙nm-1 Up to 150 W∙m-2 Up to 1300 W∙m-2 Up to 150 W∙m -2 Up to 1300 W∙m-2 Up to 150 W∙m -2 Up to 1300 W∙m-2 Up to 150 W∙m -2 Up to 1300 W∙m-2 7.9 % 6.8 % 9.7 % 7.1 % 14 % 7.1 % 7.9 % 6.8 % 13 % 12 % 9.1 % 9.1 % 10 % 6.9 % 8.4 % 6.8 % Daylight, SolarStandard, WG, StoreLight ID65 XC270, XC300, XC320, XC320HLF, 7IR, 16H 4IR3WG, 6IR1UV, GMW3414, 10WG, TM16, DL Ex. IR, B04 XC320, XC320HLF, 7IR, 16H, 4IR3WG, 6IRiUV, GMW3414 XC270, XC300, B04 10WG, TM16 DL Ext. IR WIN
to 240 klx
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2101.01) 9/24/2025 Page 3 of 6 Parameter/Equipment Range CMC2, 7 (±) Comments6, 9 Location11 Irradiance3, 4 (With Xenocal) – (cont) Ci Instruments: 340 nm – Spectral 420 nm – Spectral (300 to 400) nm Up to 1.4 W∙m -2∙nm-1 Up to 3.5 W∙m-2∙nm-1 Up to 150 W∙m-2 8.7 % 7.3 % 11 % Boro S/Boro-S WIN Irradiance3, 4 (With Reference Lamp) – 340 nm – Spectral 420 nm – Spectral (300 to 400) nm Up to 3.3 W∙m -2∙nm-1 Up to 7.8 W∙m-2∙nm-1 Up to 400 W∙m-2 5.8 % 5.5 % 5.6 % Hioki PW3335 wattmeter w/Hioki 9660 current probe, Boro S/Boro-S WIN Irradiance3, 4 (With Reference Radiometer) – Fluorescent Instruments: (310, 340, 351) nm – Spectral 254 nm – Spectral Up to 3.0 W∙m -2∙nm-1 Up to 16.0 mW∙cm-2∙nm-1 7.6 % 10 % UV test UVC test WIN Irradiance (Calibration Standards) – Customer Xenon Ref. Lamps for Ci Instruments Operating at: Lamp AC Power up to 6 kW: 340 nm – Spectral 420 nm – Spectral (300 to 400) nm Up to 3.3 W∙m -2∙nm-1 Up to 7.8 W∙m-2∙nm-1 Up to 400 W∙m-2 5.5 % 4.4 % 4.9 % SP320 instrument systems spectroradiometer, Hioki PW3335 wattmeter w/Hioki 9660 current probe & 2 working standards MPL
300 to 400 nm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2101.01) 9/24/2025 Page 4 of 6 Parameter/Equipment Range CMC2, 7 (±) Comments6 Location11 Irradiance (Calibration Standards) – (cont) Customer Xenon Ref. Lamps for Ci Instruments Operating at: Lamp AC Power up to 12 kW: 340 nm – Spectral 420 nm – Spectral (300 to 400) nm Customer Ref. UV Radiometers for Fluorescent Instruments: UV Test Fluorescent Instrument: 310/340/351 nm – Spectral UVC Test Instrument 254 nm – Spectral Up to 3.3 W∙m-2∙nm-1 Up to 7.8 W∙m-2∙nm-1 Up to 400 W∙m-2 Up to 3.0 W∙m -2∙nm-1 Up to 16.0 mW∙cm -2∙nm-1 5.8 % 5.5 % 5.6 % 7.6 % 10 % Boro S/Boro-S SP320 instrument systems, spectroradiometer & 3 working standards ILT2400 photometer & 3 working standards MPL Irradiance – XenoCal/XENOSENSIV (110 to 1300) W/m 2 (12 to 150) W/m 2 (0.10 to 1.4) W/m 2 (0.3 to 3.5) W/m2 5.8 % 6.2 % 7.0 % 5.8 % Wavelength (300 to 800) nm Wavelength (300 to 400) nm Wavelength 340 nm Wavelength 420 nm Note: Restricted to Xenon radiation at the Atlas calibration facility LAL
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2101.01) 9/24/2025 Page 5 of 6 II. Thermodynamics _________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. Parameter/Equipment Range CMC2, 7 (±) Comments Location11 Illuminance – XenoCal/XENOSENSIV (20 to 250) klx 3.0 % Restricted to Xenon radiation at the Atlas calibration facility LAL Irradiance – Xenon Customer Xenon Ref. Lamps for Ci Instruments Operating at: Lamp AC Power Up to 6 kW: 340 nm 420 nm (300 to 400) nm Up to 3.3 W·m -2·nm-1 Up to 7.8 W·m-2·nm-1 Up to 400 W·m-2 5.5 % 4.4 % 4.9 % SP320 instrument systems spectroradiometer, Hioki PW3335 wattmeter w/ Hioki 9660 current probe & 2 working standards Boro S/Boro-S LAL Parameter/Equipment Range CMC2 (±) Comments10 Location11 Radiation Thermometers – XenoCal/XENOSENSIV XENOSENSIV BPT-C 3 (20 to 120) °C (30 to 80) °C 0.8 °C 0.5 °C BST/WST/BPT/WPT Testo 735 reference RTD thermometer LAL
20 to 250 klx
6ASTM G179-04; ISO17025; ISO 4892-1; ISO 4892- 1--
7ISO/IEC 17025:20 17; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1500 Bishop Court, Mount Prospect, IL, 60056, US

42.07882, -87.91300

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.