Registers refreshed 2026-11-08.See refresh dates
United States

Wm. T. Burnett & Co. Foam Division

Quality Control Laboratory, 2112 Montevideo Road, 20794, Jessup, MD, United States

Visit website
A2LA 1811.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 13 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO9
ISO 845Cellular plastics and rubbers - Determination of apparent density
ISO 1798Flexible cellular polymeric materials - Determination of tensile strength and elongation at break
ISO 1856Flexible cellular polymeric materials - Determination of compression set
ISO 2439Flexible cellular polymeric materials - Determination of hardness (indentation technique)
ISO 2440Flexible and rigid cellular polymeric materials - Accelerated ageing tests
ISO 3386
ISO 3795Road vehicles, and tractors and machinery for agriculture and forestry - Determination of burning behaviour of interior materials
ISO 7231Polymeric materials, cellular, flexible - Determination of air flow value at constant pressure-drop
ISO 8067Flexible cellular polymeric materials - Determination of tear strength
ASTM4
ASTM D461
ASTM D1056
ASTM D3574Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Polyurethane Foams
ASTM D3776

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

1811.01

The scope document we hold says it is valid until 2027-10-31.

View scope

Accredited scope, certificate 1811.01

LineMethodMatrixRange
1ASTM D3574; ISO 845; JIS K6400; ASTM D3776; ASTM D461; ISO 1798; ISO 8067; GMW 14695; ISO 7231; ASTM D1056; ISO 3386/1; ISO 2439; Ford ESA-M4D200B; Delphi SD2-209; DaimlerChrysler MS-AY-326; GMW16750; Ford BO 112-03; GMW 17408; ISO 1856polyurethane cellular plastic, polyester, and other fiber batting products and composites-
2ASTM D3574, Test J; ISO 2440; Ford FLTM BO 012-01; ASTM D3574, Test K; ISO 2440; California Technical Bulletin 117 – (2013), Section 3; FAA 25.853, Para. A; GM 9070P (Withdrawn); ISO 3795; JIS K6400, Sec. 12, Method A; SAE J369; 49 CFR 571.302 (MVSS302); Ford FLTM BN 024-02; GMW 3232--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited WM. T. BURNETT & CO. FOAM DIVISION Jessup, MD for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 8th day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1811.01 Valid to October 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Quality Control Laboratory, 2112 Montevideo Road, Jessup, MD, 20794, US

39.14927, -76.77525

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.