Wm. T. Burnett & Co. Foam Division
Quality Control Laboratory, 2112 Montevideo Road, 20794, Jessup, MD, United States
Visit website- Accredited standards
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO9
ISO 845Cellular plastics and rubbers - Determination of apparent density
ISO 1798Flexible cellular polymeric materials - Determination of tensile strength and elongation at break
ISO 1856Flexible cellular polymeric materials - Determination of compression set
ISO 2439Flexible cellular polymeric materials - Determination of hardness (indentation technique)
ISO 2440Flexible and rigid cellular polymeric materials - Accelerated ageing tests
ISO 3386
ISO 3795Road vehicles, and tractors and machinery for agriculture and forestry - Determination of burning behaviour of interior materials
ISO 7231Polymeric materials, cellular, flexible - Determination of air flow value at constant pressure-drop
ISO 8067Flexible cellular polymeric materials - Determination of tear strength
ASTM4
ASTM D461
ASTM D1056
ASTM D3574Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Polyurethane Foams
ASTM D3776
ASTM D3574; ISO 845; JIS K6400; ASTM D3776; ASTM D461; ISO 1798; ISO 8067; GMW 14695; ISO 7231; ASTM D1056; ISO 3386/1; ISO 2439; Ford ESA-M4D200B; Delphi SD2-209; DaimlerChrysler MS-AY-326; GMW16750; Ford BO 112-03; GMW 17408; ISO 1856
ASTM D3574, Test J; ISO 2440; Ford FLTM BO 012-01; ASTM D3574, Test K; ISO 2440; California Technical Bulletin 117 – (2013), Section 3; FAA 25.853, Para. A; GM 9070P (Withdrawn); ISO 3795; JIS K6400, Sec. 12, Method A; SAE J369; 49 CFR 571.302 (MVSS302); Ford FLTM BN 024-02; GMW 3232
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1811.01
The scope document we hold says it is valid until 2027-10-31.
Accredited scope, certificate 1811.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D3574; ISO 845; JIS K6400; ASTM D3776; ASTM D461; ISO 1798; ISO 8067; GMW 14695; ISO 7231; ASTM D1056; ISO 3386/1; ISO 2439; Ford ESA-M4D200B; Delphi SD2-209; DaimlerChrysler MS-AY-326; GMW16750; Ford BO 112-03; GMW 17408; ISO 1856 | polyurethane cellular plastic, polyester, and other fiber batting products and composites | - |
| 2 | ASTM D3574, Test J; ISO 2440; Ford FLTM BO 012-01; ASTM D3574, Test K; ISO 2440; California Technical Bulletin 117 – (2013), Section 3; FAA 25.853, Para. A; GM 9070P (Withdrawn); ISO 3795; JIS K6400, Sec. 12, Method A; SAE J369; 49 CFR 571.302 (MVSS302); Ford FLTM BN 024-02; GMW 3232 | - | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
WM. T. BURNETT & CO. FOAM DIVISION
Jessup, MD
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 8th day of August 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1811.01
Valid to October 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Quality Control Laboratory, 2112 Montevideo Road, Jessup, MD, 20794, US
39.14927, -76.77525
Open in MapsLabs with overlapping accredited scope in United States
- John J Farber Technology and Innovation CenterRichmond, IN · ~700 kmA2LAShares 1 accredited test methodISO 3795
- Touchstone Systems & ServicesWyoming, MI · ~857 kmA2LAShares 1 accredited test methodISO 3795
- Advanced Composites, Inc. Tennessee Facility - EngineeringNashville, TN · ~941 kmA2LAShares 1 accredited test methodISO 3795
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.