Laboratorio di Analisi Microbiologiche e Chimiche delle Acque, Dipartimento di Scienze Chimiche, Biologiche Farmaceutiche ed Ambientali. Università di Messina
Viale Palatucci snc - Polo Universitario Annunziata, 98168, Messina, Italy
Visit website- Accredited standards
- 7
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2060 Man 29 2003pH
APAT CNR IRSA 5080 Man 29 2003
EN 26461-2Water quality - Detection and enumeration of the spores of sulfite-reducing anaerobes (clostridia) - Part 2: Method by membrane filtration
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; APAT CNR IRSA 5060 Man 29 2003; UNI EN 26461-2:1994; UNI EN ISO 11885:2009; Rapporti ISTISAN 2007/31 pag 164 Met ISS CAA036; APAT CNR IRSA 2110 Man 29 2003; Rapporti ISTISAN 2007/05 pag 188 Met ISS A018A; UNI EN ISO 9308
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 5080 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; DM 10/02/2015 GU n 50 02/03/2015 All IV Par 2.1
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
3 lines
ISO/IEC 17025
Active02111
Accredited scope, certificate 02111
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; APAT CNR IRSA 5060 Man 29 2003; UNI EN 26461-2:1994; UNI EN ISO 11885:2009; Rapporti ISTISAN 2007/31 pag 164 Met ISS CAA036; APAT CNR IRSA 2110 Man 29 2003; Rapporti ISTISAN 2007/05 pag 188 Met ISS A018A; UNI EN ISO 9308 | Acque destinate al consumo umano (1)/Drinking waters (1); Acque minerali naturali (1)/Natural mineral waters (1); Acque trattate (1)/Treated waters (1); Acque sotterranee/Ground waters; Acque di piscina (1)/Swimming pool waters (1); Acque naturali (1)/Natural waters (1); Acque naturali con bassa contaminazione microbica/Natural water with low bacteria numbers | - |
| 2 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 5080 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; DM 10/02/2015 GU n 50 02/03/2015 All IV Par 2.1 | Drinking water | - |
| 3 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003 | Waste water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Viale Palatucci snc - Polo Universitario Annunziata, Messina, 98168, IT
38.19376, 15.55421
Open in MapsLabs with overlapping accredited scope in Italy
- ECOPOINTAvezzano · ~460 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003APAT CNR IRSA 5080 Man 29 2003Drinking water
- ALS ItaliaMoncalieri · ~1,000 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003APAT CNR IRSA 5080 Man 29 2003Drinking water
- ENVI.SE.P. s.a.s. di Maggiore Riccardo Vincenzo Maria & C.Catania · ~87 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Drinking waterWaste water
- Servizi Ambientali IntegratiLamezia Terme · ~108 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Drinking waterWaste water
- ECOCONTROLCaraffa di Catanzaro · ~111 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Drinking waterWaste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.