Registers refreshed 2026-11-08.See refresh dates
Poland

Zakłady Metalowe DEZAMET Spółka Akcyjna

ul. Szypowskiego 1, 39-460, Nowa Dęba, Poland

PCA AB 1245ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
16
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 16 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO6
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 5667 series4
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5667-11Water quality - Sampling - Part 11: Guidance on sampling of groundwaters
EN3
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance

Certificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.

EN 27888Water quality - Determination of electrical conductivity
Other standards3
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

5 lines
PCA

ISO/IEC 17025

Active

AB 1245

The scope document we hold says it is valid until 2027-03-07.

View on PCA

Accredited scope, certificate AB 1245

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1245 Scope of accreditation No. AB 1245 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1245 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 18 z/of 07.01.2026 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1 245 z dnia 23.01.2020 r. Cykl akredytacji od 07.02.2023 r. do 07.03.2027 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1245 of 23.01.2020 Accreditation cycle from 07.02.2023 to 07.03.2027 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 18, 07.01.2026 1/6 Nazwa i adres / Name and address ZAKŁADY METALOWE DEZAMET S.A. LABORATORIUM BADAWCZE ul. Szypowskiego 1 39-460 Nowa Dęba Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/28/P; C/29/P; C/30/P - G/33 - N/28/P; N/29/P; N/30/P - N/33/P - P/33 - Badania chemiczne i pobieranie próbek , wody, wody do spożycia przez ludzi, ścieków / Chemical tests and sampling of water, drinking water, sewage - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie) / Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting) - Badania właściwości fizycznych i pobieranie próbek, wody, wody do spożycia przez ludzi , ścieków / Tests of physical properties and sampling of water, drinking water, sewage - Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynnik i szkodliwe – powietrze / Tests of physical properties and sampling - working environment (harmful factors – air) - Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze) / Sampling - working environment (harmful factors – air) Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1245
-
2PN-ISO 15705:2005; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-EN 27888:1999; PB - 16/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114752; PB - 02/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114773; PB - 17/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114776; PB - 03/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114897; PB - 04/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114758; PB - 24/ZS Wydanie 1 z dnia 05.05.2022 r. na podstawie testu Spectroquant® nr 109701; PB - 07/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114832; PB - 08/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114848; PB - 09/ZS Wydanie 1 z dnia 18.06.2019 r. na podstawie testu Spectroquant® nr 114767Drinking waterSee scope document
3PN-EN ISO 10304-1:2009+AC:2012; PN-ISO 5667-10:2021-11; PN-ISO 5667-5:2017-10; PN-EN-ISO 5667-6:2016-12; PN-ISO 5667-11:2017-10; PN-88/C-04621; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03Drinking waterSee scope document
4PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015; PN-EN 14253+A1:2011Workplace environmentSee scope document
5PN-Z-04008/07:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08Workplace air0.14 to 20 mg/m3

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Szypowskiego 1, Nowa Dęba, 39-460, PL

50.41349, 21.75413

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.