Pace Analytical Life Sciences, LLC, Technical Field Services

727 Kasota Ave SE, 55414, Minneapolis, MN, United States

Visit website
A2LA 2700.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 2700.01 · 2 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2700.01) 06/05/2024 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PACE ® ANALYTICAL LIFE SCIENCES, LLC, TECHNICAL FIELD SERVICES 727 Kasota Ave SE Minneapolis, MN 55414 Jodi Taylor Phone: 612-719-4375 CALIBRATION Valid To: June 30, 2026 Certificate Number: 2700.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Thermodynamic Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measuring Equipment By Comparison (-90 to 0) °C (0 to 100) °C (100 to 140) °C (140 to 400) °C (-30 to 100) °C 0.12 °C 0.13 °C 0.13 °C 0.10 °C 0.080 °C Hart 1502A, Hart 5615 PRT, dry wells Hart 1502A, Hart 5615 PRT, Hart 7103 microbath _____________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
2ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

727 Kasota Ave SE, Minneapolis, MN, 55414, US

44.97730, -93.26547

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.