Registers refreshed 2026-11-08.See refresh dates
United States

Thompson Equipment Company

125 Industrial Avenue, 70121, New Orleans, LA, United States

Visit website
A2LA 3341.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3341.01 · 3 lines

Below is the text of the scope document as published.

Part 1 of 3

(A2LA Cert. No. 3341.01) 09/05/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 THOMPSON EQUIPMENT COMPANY 125 Industrial Avenue New Orleans, LA 70121 Todd Thompson Phone: 504 833 6381 CALIBRATION Valid To: October 31, 2026 Certificate Number: 3341.01 In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Fluid Quantities Parameter/Equipment Range CMC 2, 3, 4 (±) Comments Liquid Flow – Measuring Equipment (6 to 16) gpm (34 to 120) gpm (210 to 750) gpm (735 to 3000) gpm 0.15 % 0.12 % 0.13 % 0.25 % Comparison to standard flowmeters: micro motion flowmeters Rosemount flowmeter __________________________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted.

Part 2 of 3

(A2LA Cert. No. 3341.01) 09/05/2024 Page 2 of 2 4 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.

Part 3 of 3

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited THOMPSON EQUIPMENT COMPANY New Orleans, LA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of September 2024. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3341.01 Valid to October 31, 2026

Extracted from the scope document; tables may not line up. View scope for the original.

Location

125 Industrial Avenue, New Orleans, LA, 70121, US

29.95591, -90.07303

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.