ELECTRONICS PRODUCT DEVELOPMENT CENTER
EPDC Bldg., MIRDC compound, Gen. Santos Ave., Bicutan, Taguig City, 1631, Philippines, Taguig City, Philippines
Visit website- Accredited standards
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 22 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
Other standards3
FCC PART 15Radio Frequency Devices
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
CISPR 11; CISPR 14-1; CISPR 32; EN 55032; CFR 47, FCC Part 15B (using ANSI C63.4:2014); IEC 61000-3-2; IEC 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6; IEC/EN 61000-4-8; IEC/EN 61000-4-11; IEC/EN 61000-6-1; IEC/EN 61000-6-3; IEC/EN 61000-6-4; CISPR 14-2; CISPR 35; EN 55035; ISO/IEC 17025:2017
CISPR 25; ISO11452-2; ISO11452-4; IEC 62368-1; IEC 62368-1:2023; IEC 60068-2-1; IEC 60068-2-2; ANSI C63.4:2014
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active5144.01
The scope document we hold says it is valid until 2027-07-31.
Accredited scope, certificate 5144.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CISPR 11; CISPR 14-1; CISPR 32; EN 55032; CFR 47, FCC Part 15B (using ANSI C63.4:2014); IEC 61000-3-2; IEC 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6; IEC/EN 61000-4-8; IEC/EN 61000-4-11; IEC/EN 61000-6-1; IEC/EN 61000-6-3; IEC/EN 61000-6-4; CISPR 14-2; CISPR 35; EN 55035; ISO/IEC 17025:2017 | - | 9 to 8 kHz to GHz |
| 2 | CISPR 25; ISO11452-2; ISO11452-4; IEC 62368-1; IEC 62368-1:2023; IEC 60068-2-1; IEC 60068-2-2; ANSI C63.4:2014 | Medical equipment, electrical safety and EMC | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
ELECTRONICS PRODUCT DEVELOPMENT CENTER
Taguig City, Philippines
for technical competence in and compliance with the
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 22nd day of September 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5144.01
Valid to July 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.