X-Rite Europe
Wehntalerstrasse 61a, Regensdorf, 8105, Switzerland, Regensdorf, Switzerland
- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2108.07 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.07) 01/06/2026 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO 17025:2017
X-RITE EUROPE GMBH
Wehntalerstrasse 61a
Regensdorf, 8105, SWITZERLAND
Kevin Irwin Phone: 616 219 8681
CALIBRATION
Valid To: January 31, 2028 Certificate Number: 2108.07
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Optical Quantities
Parameter/Equipment4
Range
CMC2, 3 (±)
Comments5
Spectrophotometers –
Model eXact (NGH)
(0/45 Optical Geometry)
Model eXact 2 (ETV)
(0/45 Optical Geometry)
(400 to 410) nm
(420 to 700) nm
(400 to 410) nm
(420 to 700) nm
1.8 % R
1.1 % R
1.8 % R
1.1 % R
White reflection
standards with:
SPP eXact
SPP ETV | ||
| 2 | - | White reflection standardsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.07) 01/06/2026 Page 2 of 3
Parameter/Equipment4
Range
CMC2, 3 (±)
Comments5
Spectrophotometers –
(cont)
Model MA-x Series and
OEM Variants (TOP
Spectro-photometer)
(Aspecular Optical
Geometry):
15 °
25 °
45 °
75 °
110 °
Model MA-x Series and
OEM Variants (TOP II
Spectro-photometer)
(Aspecular Optical
Geometry):
-15 °
15 °
25 °
45 °
75 °
110 °
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
(400 to 700) nm
(400 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
1.2 % R
1.1 % R
1.2 % R
1.1 % R
1.1 % R
0.96 % R
1.2 % R
1.0 % R
1.2 % R
1.6 % R
1.2 % R
1.1 % R
1.0 % R
1.1 % R
0.96 % R
1.1 % R
1.0 % R
1.2 % R
White reflection
standards with:
Topaz service
manual
Topaz II service
manual
_________________________________
1 This laboratory offers commercial calibration service. | 400 to 700 nm |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.07) 01/06/2026 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, R is the reflectance.
4 The product families have the same optical geometries and calibration procedures. The features on the
display and outputs are the only differences.
5 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white
ceramic. Color calibration is mainly based on inter-instrument agreement.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.