Switzerland

X-Rite Europe

Wehntalerstrasse 61a, Regensdorf, 8105, Switzerland, Regensdorf, Switzerland

A2LA 2108.07ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2108.07 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.07) 01/06/2026 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO 17025:2017 X-RITE EUROPE GMBH Wehntalerstrasse 61a Regensdorf, 8105, SWITZERLAND Kevin Irwin Phone: 616 219 8681 CALIBRATION Valid To: January 31, 2028 Certificate Number: 2108.07 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Optical Quantities Parameter/Equipment4 Range CMC2, 3 (±) Comments5 Spectrophotometers – Model eXact (NGH) (0/45 Optical Geometry) Model eXact 2 (ETV) (0/45 Optical Geometry) (400 to 410) nm (420 to 700) nm (400 to 410) nm (420 to 700) nm 1.8 % R 1.1 % R 1.8 % R 1.1 % R White reflection standards with: SPP eXact SPP ETV
2-White reflection standards
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.07) 01/06/2026 Page 2 of 3 Parameter/Equipment4 Range CMC2, 3 (±) Comments5 Spectrophotometers – (cont) Model MA-x Series and OEM Variants (TOP Spectro-photometer) (Aspecular Optical Geometry): 15 ° 25 ° 45 ° 75 ° 110 ° Model MA-x Series and OEM Variants (TOP II Spectro-photometer) (Aspecular Optical Geometry): -15 ° 15 ° 25 ° 45 ° 75 ° 110 ° (400 to 410) nm (420 to 700) nm 400 nm (410 to 700) nm 400 nm (410 to 700) nm (400 to 410) nm (420 to 700) nm (400 to 700) nm (400 to 700) nm (400 to 700) nm 400 nm (410 to 700) nm 400 nm (410 to 700) nm (400 to 410) nm (420 to 700) nm (400 to 700) nm 1.2 % R 1.1 % R 1.2 % R 1.1 % R 1.1 % R 0.96 % R 1.2 % R 1.0 % R 1.2 % R 1.6 % R 1.2 % R 1.1 % R 1.0 % R 1.1 % R 0.96 % R 1.1 % R 1.0 % R 1.2 % R White reflection standards with: Topaz service manual Topaz II service manual _________________________________ 1 This laboratory offers commercial calibration service.
400 to 700 nm
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.07) 01/06/2026 Page 3 of 3 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, R is the reflectance. 4 The product families have the same optical geometries and calibration procedures. The features on the display and outputs are the only differences. 5 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white ceramic. Color calibration is mainly based on inter-instrument agreement. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Wehntalerstrasse 61a, Regensdorf, 8105, Switzerland, Regensdorf, CH

47.43176, 8.46804

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.