Metrology Laboratory Saudia Technic
King AbdulAziz International Airport, Building 202, Saudia Technic, Jeddah, 21231, Saudi Arabia, Jeddah, Saudi Arabia
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 3211.01 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Conductivity solutionsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 1 of 21
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
METROLOGY LABORATORY SAUDIA TECHNIC
King Abdulaziz International Airport, Building 202.
PO Box 167 CC: 833, Jeddah, Saudi Arabia 21231
Sami Kharmi Phone: +966 12 272 9001 ext. 833004
CALIBRATION
Valid Until: March 31, 2026 Certificate Number: 3211.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following calibrations
1, 6:
I. Acoustic Quantities
Parameter/Range Frequency CMC2, 7 (±) Comments
Sound Measuring
Equipment – Acoustical
Level 114 dB, Fixed
Points
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
0.63 dB
0.63 dB
0.43 dB
0.63 dB
0.63 dB
GenRad 1562A
II. Chemical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Conductivity Meters
1413 µS/cm
8.2 + 0.6R µS/cm
Conductivity
solutions
pH Meters
4 pH
7 pH
10 pH
1.2e-02 pH + 0.6R
1.2e-02 pH + 0.6R
1.2e-02 pH + 0.6R
pH buffer solutions | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 2 of 21
III. Dimensional
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Micrometers
Up to 50 in
(1.86 + 5L) µin + 0.6R
Gage blocks
Calipers
Up to 70 in
(2.0 + 1.84L) µin +
0.6R
Gage blocks
Length Indicators
(Dial, Test, Transducers)
Up to 1.0 in
Up to 6.0 in
0.000 12 in
(3.0 + 1.5L) µin + 0.6R
Indicator calibrator,
gage blocks
Heights Gages
Up to 40 in
(0.35 + 1.95L) µin +
0.6R
Gage blocks
Linear Measure (Milling
Machines, CNC, etc.)
Up to 4 in
0.9 µin/in + 0.6R
Agilent 5519B
laser system with
weather station
Crimping Tools
Up to 0.500 in (Go-No
Go Requirements)
0.000 11 in
Pin gages
Optical Flats
Up to 6 in
4 µin
Optical flats
Levels
Up to 90°
0.05°
Angle blocks, gage
blocks, surface plate
Surface Plates
Up to 87 in (diagonal
length)
0.368 + 0.345DL µin
Agilent 5519B
laser system with
weather station | to 50 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 3 of 21
IV. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 3, 4, 8 (±)
Comments
DC Voltage – Generate
Fixed Points
1.018 V
10.000 V
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
3.1 µV/V
2.4 µV/V
8.9 µV/V + 0.4 µV
5.8 µV/V + 0.7 µV
4.2 µV/V + 2.5 µV
4.3 µV/V + 4.0 µV
5.9 µV/V + 40 µV
7.6 µV/V + 0.4 mV
Fluke DC voltage
standard 732B with
Agilent 3458A opt 002
Fluke 5720A/5725A
with Agilent 3458A
opt 002
DC Voltage – Measure
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
5.8 µV/V + 0.3 µV
4.6 µV/V + 0.3 µV
4.6 µV/V + 0.5 µV
6.9 µV/V + 30 µV
7.0 µV/V + 100 µV
Agilent 3458A opt 002
with Fluke 5720A
DC Current – Generate
Clamp Meters
(0 to 220) μA
220 μA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(10 to < 16.5) A
(16.5 to < 150) A
(150 to 1000) A
47 µA/A + 6.0 nA
41 µA/A + 7.0 nA
42 µA/A + 40 nA
53 µA/A + 0.7 µA
95 µA/A + 12 µA
420 µA/A + 480 µA
1.2 mA/A + 750 µA
7.8 mA/A + 0.02 A
5.8 mA/A + 0.14 A
5.8 mA/A + 0.50 A
Fluke 5720A/5725A
with Agilent 3458A opt
002
Fluke 5720A/5725A
with Fluke 8508A
Fluke 5522A
Fluke 5522A with
Fluke 5500A coil
DC Current – Measure
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 2) A
(2 to 20) A
24 µA/A + 0.1 nA
23 µA/A + 0.8 nA
23 µA/A + 5 nA
23 µA/A + 50 nA
40 µA/A + 0.5 µA
130 µA/A + 10 µA
200 µA/A + 16 µA
440 µA/A + 400 µA
Agilent 3458A opt 002
Fluke 8508A | to 1100 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 4 of 21
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
DC Power – Generate
0.01 mW to 21 kW
33 mV to 1020 V
(0.33 to 329.99) mA
(0.33 to 2.9999) A
(3 to 20.5) A
0.33 mW/W
0.33 mW/W
0.86 mW/W
Fluke 5522A
Parameter/Range
Frequency
CMC2, 3, 8 (±)
Comments
AC Voltage – Generate
(0 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
720 µV/V + 4 µV
650 µV/V + 4 µV
650 µV/V + 4 µV
940 µV/V + 4 µV
1.3 mV/V + 5 µV
2.2 mV/V + 10 µV
4.1 mV/V + 20 µV
3.2 mV/V + 20 µV
300 µV/V + 4 µV
140 µV/V + 4 µV
130 µV/V + 4 µV
260 µV/V + 4 µV
600 µV/V + 5 µV
1.3 mV/V + 10 µV
1.7 mV/V + 20 µV
3.5 mV/V + 20 µV
280 µV/V + 12 µV
110 µV/V + 7 µV
95 µV/V + 7 µV
240 µV/V + 7 µV
540 µV/V + 17 µV
1.0 mV/V + 20 µV
1.6 mV/V + 25 µV
3.2 mV/V + 45 µV
280 µV/V + 40 µV
100 µV/V + 15 µV
55 µV/V + 8 µV
89 µV/V + 10 µV
130 µV/V + 30 µV
490 µV/V + 80 µV
1.2 mV/V + 200 µV
2.1 mV/V + 300 µV
Fluke 5720A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 5 of 21
Parameter/Range Frequency CMC2, 3, 4, 8 (±) Comments
AC Voltage – Generate
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
280 µV/V + 400 µV
110 µV/V + 150 µV
55 µV/V + 50 µV
89 µV/V + 100 µV
120 µV/V + 200 µV
340 µV/V + 600 µV
1.2 mV/V + 2000 µV
2.0 mV/V + 3200 µV
280 µV/V + 4 mV
100 µV/V + 1.5 mV
64 µV/V + 0.6 mV
95 µV/V + 1 mV
180 µV/V + 2.5 mV
1.0 mV/V + 16 mV
0.11 mV/V + 4 mV
0.19 mV/V + 6 mV
0.70 mV/V + 11 mV
Fluke 5720A
Fluke
5720A/5725A
AC Voltage – Measure
Up to 10 mV
(10 to 100) mV
100 mV to 1 V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
350 µV/V + 3 µV
230 µV/V + 1.1µV
350 µV/V + 1.1µV
1.2 mV/V + 1.1µV
5.8 mV/V + 1.1µV
46 mV/V + 2 µV
84 µV/V + 4 µV
84 µV/V + 2 µV
160 µV/V + 2 µV
350 µV/V + 2 µV
920 µV/V + 2 µV
3.5 mV/V + 10 µV
12 mV/V + 10 µV
82 µV/V + 40 µV
82 µV/V + 20 µV
160 µV/V + 20 µV
350 µV/V + 20 µV
920 µV/V + 20 µV
3.5 mV/V + 100 µV
12 mV/V + 100 µV
Agilent 3458A opt
002 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 6 of 21
Parameter/Range Frequency CMC2, 4, 8 (±) Comments
AC Voltage – Measure
(cont)
(1 to 10) V
(10 to 100) V
(100 to 700) V
(200 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
84 µV/V + 0.4 mV
82 µV/V + 0.2 mV
160 µV/V + 0.2 mV
350 µV/V + 0.2 mV
920 µV/V + 0.2 mV
3.5 mV/V + 1 mV
12 mV/V + 1 mV
230 µV/V + 4 mV
230 µV/V + 2 mV
230 µV/V + 2 mV
400 µV/V + 2 mV
1.4 mV/V + 2 mV
4.6 mV/V + 10 mV
460 µV/V + 40 mV
460 µV/V + 20 mV
690 µV/V + 20 mV
1.4 mV/V + 20 mV
160 µV/V + 40 mV
130 µV/V + 20 mV
110 µV/V + 20 mV
250 µV/V + 20 mV
Agilent 3458A opt
002
Fluke 8508A
AC Current – Measure
Up to 100 μA
100 µA to 1 mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
4.6 mA/A + 30 nA
1.7 mA/A + 30 nA
690 µA /A + 30 nA
690 µA /A + 30 nA
4.6 mA/A + 0.2 µA
1.7 mA/A + 0.2 µA
690 µA/A + 0.2 µA
350 µA/A + 0.2 µA
690 µA/A + 0.2 µA
4.6 mA/A + 2 µA
1.7 mA/A + 2 µA
690 µA/A + 2 µA
350 µA/A + 2 µA
690 µA/A + 2 µA
Agilent 3458A opt
002 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 7 of 21
Parameter/Range Frequency CMC2, 3, 4, 8 (±) Comments
AC Current – Measure
(cont)
(10 to 100) mA
100 mA to 1 A
(1 to 2) A
(2 to 20) A
(10 up to 20) Hz
(20 up to 45) Hz
(45 up to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 2) kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
4.6 mA/A + 20 µA
1.7 mA/A + 20 µA
690 µA/A + 20 µA
350 µA/A + 20 µA
690 µA/A + 20 µA
4.6 mA/A + 200 µA
1.9 mA/A + 200 µA
0.93 mA/A + 200 µA
1.2 mA/A + 200 µA
3.5 mA/A + 200 µA
700 µA/A + 0.2 mA
930 µA/A + 0.2 mA
930 µA/A + 2 mA
2.9 mA/A + 2 mA
Agilent 3458A opt
002
Fluke 8508A
AC Current – Generate
Up to 220 μA
220 µA to < 2.2 mA
(2.2 to < 22) mA
(22 to < 220) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
310 µA/A + 16 nA
210 µA/A + 10 nA
170 µA/A + 8 nA
340 µA/A + 12 nA
1.3 mA/A + 65 nA
300 µA/A + 40 nA
200 µA/A + 35 nA
160 µA/A + 35 nA
240 µA/A + 110 nA
1.2 mA/A + 650 nA
300 µA/A + 40 nA
200 µA/A + 35 nA
150 µA/A + 35 nA
240 µA/A + 550 nA
1.3 mA/A + 5000 nA
300 µA/A + 4.0 µA
200 µA/A + 3.5 µA
150 µA/A + 2.5 µA
240 µA/A + 3.5 µA
1.3 mA/A + 10 µA
Fluke5720A/5725A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 8 of 21
Parameter/Range Frequency CMC2, 3, 8 (±) Comments
AC Current – Generate
(cont)
220 mA to < 2.2 A
(2.2 A to < 11) A
Up to 330 μA
330 μA to < 3 mA
(3 to < 33) mA
(33 to < 330) mA
330 mA to < 1.1 A
(1.1 A to < 3) A
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.31 mA/A + 35 µA
0.53 mA/A + 80 µA
8.1 mA/A + 160 µA
0.53 mA/A + 170 µA
1.1 mA/A + 380 µA
4.2 mA/A + 750 µA
3.2 mA/A + 0.1 µA
2.8 mA/A + 0.1 µA
2.0 mA/A + 0.1 µA
4.3 mA/A + 0.15 µA
10 mA/A + 0.2 µA
21 mA/A + 0.4 µA
1.5 mA/A + 0.15 µA
1.2 mA/A + 0.15 µA
2.3 mA/A + 0.2 µA
5.8 mA/A + 0.3 µA
12 mA/A + 0.6 µA
2.1 mA/A + 2 µA
1.0 mA/A + 2 µA
0.5 mA/A + 2 µA
0.9 mA/A + 2 µA
2.3 mA/A + 3 µA
4.7 mA/A + 4 µA
2.1 mA/A + 20 µA
1.0 mA/A + 20 µA
0.5 mA/A + 20 µA
1.2 mA/A + 50 µA
2.3 mA/A + 100 µA
4.6 mA/A + 200 µA
2.1 mA/A + 0.1 mA
2.1 mA/A + 0.1 mA
0.6 mA/A + 0.1 mA
6.9 mA/A + 1 mA
29 mA/A + 5 mA
2.1 mA/A + 0.1 mA
0.8 mA/A + 0.1 mA
6.9 mA/A + 1 mA
29 mA/A + 5 mA
Fluke 5720A/5725A
Fluke 5522A | 0.00033 to 11 A |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 9 of 21
Parameter/Range
Frequency CMC2, 3, 8 (±) Comments
AC Current – Generate
(cont)
(3 to < 11) A
(11 to < 20.5) A
Current Clamps –
Toroidal
(10 to < 16.5) A
(16.5 to < 150) A
(150 to 1000) A
Non-Toroidal
(10 to < 16.5) A
(16.5 to < 150) A
(150 to 1000) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.7 mA/A + 2 mA
1.2 mA/A + 2 mA
3.5 mA/A + 2 mA
1.4 mA/A + 5 mA
1.8 mA/A + 5 mA
3.5 mA/A + 5 mA
4.9 mA/A + 0.003 A
11 mA/A + 0.003 A
3.3 mA/A + 0.025 A
9.2 mA/A + 0.027 A
3.2 mA/A + 0.09 A
9.1 mA/A + 0.1 A
7.5 mA/A + 0.03 A
13 mA/A + 0.03 A
6.5 mA/A + 0.25 A
12 mA/A + 0.25 A
6.5 mA/A + 0.9 A
12 mA/A + 0.9 A
Fluke 5522A
Fluke 5522A with
Fluke 5500A coil
Parameter/Equipment Range CMC2, 8 (±) Comments
AC Power – Generate
0.01 mW to 21 kW
33 mV to 1020 V
(45 to 65) Hz
(0.33 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(0.33 to 0.8999) A
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
3.8 mW/W
2.2 mW/W
1.0 mW/W
0.38 mW/W
0.78 mW/W
0.40 mW/W
0.30 mW/W
0.86 mW/W
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 10 of 21
Parameter/Equipment
Range
CMC2, 3, 4, 8 (±) Comments
Resistance – Generate,
Fixed Points
Ranged
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
330 Ω to 1.099 999 kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.999 99) kΩ
330 kΩ to 1.099 999 MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
110 µΩ/Ω
110 µΩ/Ω
27 µΩ/Ω
27 µΩ/Ω
12 µΩ/Ω
12 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
13 µΩ/Ω
13 µΩ/Ω
23 µΩ/Ω
25 µΩ/Ω
47 µΩ/Ω
56 µΩ/Ω
140 µΩ/Ω
48 µΩ/Ω + 1mΩ
41 µΩ/Ω + 1.5 mΩ
34 µΩ/Ω + 1.4 mΩ
33 µΩ/Ω + 2 mΩ
33 µΩ/Ω + 2 mΩ
33 µΩ/Ω + 20 mΩ
33 µΩ/Ω + 20 mΩ
33 µΩ/Ω + 0.2 Ω
34 µΩ/Ω + 0.2 Ω
38 µΩ/Ω + 2 Ω
37 µΩ/Ω + 2 Ω
71 µΩ/Ω + 30 Ω
150 µΩ/Ω + 50 Ω
300 µΩ/Ω + 2.5 kΩ
590 µΩ/Ω + 3.0 kΩ
3.5 mΩ/Ω + 100 kΩ
17 mΩ/Ω + 500 kΩ
Fluke 5720A with
Agilent 3458A opt
002
Fluke 5522A | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 11 of 21
Parameter/Equipment Range CMC2, 4, 8 (±) Comments
Resistance – Measure
(0 to < 10) Ω
(10 to < 100) Ω
100 Ω to < 1 kΩ
(1 to < 10) kΩ
(10 to < 100) kΩ
100 kΩ to 1 MΩ
(1 to < 10) MΩ
(10 to < 100) MΩ
100 MΩ to 1 GΩ
20 MΩ
200 MΩ
2 GΩ
20 GΩ
18 µΩ/Ω + 0.05 mΩ
14 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 5 mΩ
12 µΩ/Ω + 50 mΩ
19 µΩ/Ω + 2 Ω
70 µΩ/Ω + 0.1 kΩ
0.58 mΩ/Ω + 1 kΩ
5.8 mΩ/Ω + 10 kΩ
19 µΩ/Ω + 0.1 kΩ
73 µΩ/Ω + 1 kΩ
180 µΩ/Ω + 0.1 MΩ
610 µΩ/Ω + 0.01 GΩ
Agilent 3458A
Fluke 8508A
Audio Distortion –
Measure
20 Hz to 20 kHz
(20 to 100) kHz
1.2 dB
2.3 dB
Agilent 8903B
Oscilloscope –
DC
50 Ω Load
1 MΩ Load
Square Wave
(10 Hz to 10 kHz)
50 Ω Load
1 MΩ Load
Level Sine Wave
Flatness – 50 kHz
Reference Frequency
Time Marker –
Generate
(0 to + 6.6) V
(0 to + 130) V
(0.001 to + 6.6) V p-p
(0.001 to + 130) V p-p
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 500) MHz
(500 to 600) MHz
2 ns, 5 ns
10 ns, 20 ns, 50 ns
100 ns, 200 ns, 500 ns
1 µs, 2 µs, 5 µs
10 µs, 20 µs, 50 µs
100 µs, 200 µs, 500 µs
1 ms, 2 ms, 5 ms
10 ms, 20 ms, 50 ms
100 ms, 200 ms, 500 ms
1s, 2s, 5s
0.29 % + 40 µV
0.029 % + 25 µV
0.29 % + 40 µV
0.058 % + 5 µV
2.2 % + 100 µV
2.7 % + 100 µV
4.3 % + 100 µV
4.8 % + 100 µV
0.000 58 ns
0.0058 ns
0.058 ns
0.000 58 µs
0.0058 µs
0.058 µs
0.000 58 ms
0.0058 ms
0.058 ms
0.000 82 s
Fluke 5820A
calibrator | to 1 GΩ |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 12 of 21
Parameter/Range Frequency CMC2, 8 (±) Comments
Capacitance – Generate
Fixed Points
10 pF
100 pF
100 pF
1 kHz
1 kHz
1 kHz
0.000 24 pF
0.0024 pF
0.024 pF
GenRad 1404-C
GenRad 1404-B
ESI SC1000
(1.0 to 3.2999) nF
(3.3 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.0999) µF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.56 % + 0.01 nF
0.23 % + 0.01 nF
0.23 % + 0.3 nF
0.23 % + 1 nF
0.23 % + 3 nF
0.23 % + 10 nF
0.36 % + 30 nF
0.40 % + 100 nF
0.40 % + 300 nF
0.40 % + 1 μF
0.40 % + 3 μF
0.40 % + 10 μF
0.80 % + 30 μF
1.2 % + 100 μF
Fluke 5522A
Capacitance – Measure
(1 to 1000) pF
1 pF to 200 µF
1 kHz
1 kHz
6.0 µF/F
0.30 % of rdg + 1 digit
AH2700A
ESI 252
Inductance – Generate,
Fixed Points
1.0 mH
10.0 mH
100.0 mH
(100 to 1000) µH
(1 to 10) mH
(10 to 100) mH
(100 to 1000) mH
(1 to 10) H
1 kHz
1 kHz
1 kHz
20 kHz
10 kHz
3 kHz
1 kHz
300 Hz
0.0012 mH
0.012 mH
0.12 mH
2.3 % of rdg
2.3 % of rdg
1.9 % of rdg
0.93 % of rdg
0.93 % of rdg
GenRad 1482-E
GenRad 1482-H
GenRad 1482-L
GenRad 1491-G
Inductance – Measure
1 µH to 20 H
1 kHz
2.9 % of rdg + 1 digit
ESI 252 LCR meter | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 13 of 21
Parameter/Range
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators –
Type E
Type J
Type K
Type R
Type S
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-150 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1370) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(-160 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.58 °C
0.20 °C
0.18 °C
0.20 °C
0.25 °C
0.32 °C
0.20 °C
0.18 °C
0.21 °C
0.27 °C
0.39 °C
0.22 °C
0.20 °C
0.31 °C
0.47 °C
0.66 °C
0.41 °C
0.39 °C
0.47 °C
0.55 °C
0.42 °C
0.43 °C
0.54 °C
0.73 °C
0.29
°C
0.20 °C
0.18 °C
Fluke 5522A calibrator
Electrical Calibration of
RTD Indicating System
Pt 385, 100 Ω
(-200 to -80) °C
(> -80 to 0) °C
(> 0 to 100) °C
(> 100 to 300) °C
(> 300 to 400) °C
(> 400 to 630) °C
(> 630 to 800) °C
0.058 °C
0.058 °C
0.081 °C
0.10 °C
0.12 °C
0.14 °C
0.27 °C
Fluke 5522A calibrator | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 14 of 21
V. Electrical – RF/Microwave
Parameter/Equipment
Frequency
CMC2, 5, 8 (±)
Comments
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depth: 99 %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: 99 %
150 kHz to 10 MHz
150 kHz to 10 MHz
(10 to 1300) MHz
(10 to 1300) MHz
2.4 % of rdg + 1 digit
3.4 % of rdg + 1 digit
1.2 % of rdg + 1 digit
3.5 % of rdg + 1 digit
HP 8902A
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Depth: < 40 kHz Peak
Rate: 50 Hz to 100 kHz
Depth: < 400 kHz Peak
Rate: 20 Hz to 200 kHz
Depth: < 400 kHz Peak
150 kHz to 10 MHz
(10 to 1300) MHz
(10 to 1300) MHz
2.3 % of rdg + 1 digit
1.2 % of rdg + 1 digit
5.8 % of rdg + 1 digit
HP 8902A
Fixed Attenuators – Measure
3 dB
6 dB
10 dB
20 dB
30 dB
50 MHz to 18 GHz
2.7 % of rdg
2.7 % of rdg
2.7 % of rdg
2.7 % of rdg
2.7 % of rdg
Agilent E9327A w/
E4416A
RF Power Level –
Generate
(-90 to < -70) dBm
(-70 to < -10) dBm
(-10 to 16) dBm
(> 16 to 20) dBm
(-90 to < -70) dBm
(-70 to < -10) dBm
(-10 to 20) dBm
250 kHz to 2 GHz
(2 to 20) GHz
0.95 dBm
0.84 dBm
0.73 dBm
0.94 dBm
1.2 dBm
1.1 dBm
0.95 dBm
Agilent E8257D | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 15 of 21
Parameter/Equipment
Frequency
CMC2, 5, 8 (±)
Comments
RF Power Level –
Generate (cont)
(> 20 to 24) dB
(> 14 to 20) dB
(-17 to 14) dB
(-48 to ≤ -17) dB
(> -74 to < -48) dB
(> -94 to -74) dB
(-130 to -94) dB
(> +14 to +20) dB
(-17 to 14) dB
(-48 to ≤ -17) dB
(> -74 to < -48) dB
(> -94 to -74) dB
(-130 to -94) dB
(> 14 to 20) dB
(-17 to 14) dB
(-48 to ≤ -17) dB
(> -74 to < -48) dB
(> -94 to -74) dB
(-130 to -94) dB
(-17 to 14) dB
(-48 to ≤ -17) dB
(> -60 to < -48) dB
(-17 to 14) dB
(-48 to ≤ -17) dB
(> -60 to < -48) dB
> 100 kHz to 125 MHz
(> 125 to 300) MHz
> 300 MHz to 1.4 GHz
(> 1.4 to 3) GHz
(> 3 to 4) GHz
0.063 dB
0.062 dB
0.063 dB
0.063 dB
0.23 dB
0.58 dB
1.7 dB
0.12 dB
0.12 dB
0.12 dB
0.24 dB
0.58 dB
1.8 dB
0.29 dB
0.29 dB
0.58 dB
0.58 dB
1.2 dB
1.8 dB
0.36 dB
0.58 dB
0.59 dB
0.37 dB
0.59 dB
0.59 dB
Fluke 9640A-LPN with
Fluke 9640A-50
leveling head | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 16 of 21
Parameter/Equipment
Frequency
CMC2, 5, 8 (±)
Comments
RF Power Level –
Measure
Absolute Measure
(-60 to 0) dBm
(> 0 to 20) dBm
Relative Measure
(-20 to 20) dB
Tuned RF Power-
(-127 to < -120) dB
(-120 to 0) dB
50 MHz to < 1 GHz
(1 to < 7) GHz
(7 to < 14) GHz
(14 to < 18) GHz
50 MHz to < 1 GHz
(1 to < 7) GHz
(7 to < 14) GHz
(14 to < 18) GHz
100 kHz to 2.6 GHz
2.5 MHz to 1.3 GHz
2.1 % of rdg
2.5 % of rdg
2.7 % of rdg
3.0 % of rdg
2.4 % of rdg
2.7 % of rdg
2.9 % of rdg
3.2 % of rdg
0.082 dB
0.38 dB
0.18 dB
Agilent E9327A with
power meter
HP 8902A with 11722A
VI. Fluid Quantities
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Flow – Measuring
Fluid Flow Meters
Up to 0.25 GPM
Up to 160 GPM
0.6 % of rdg
0.36 % of rdg
FTS FT series flow
meters
VII. Mechanical
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Force – Measuring
Equipment
Up to 30 000 lbf
Up to 100 000 lbf
3 lbf
7.5 lbf
Morehouse series 200
proving rings with digital
readout | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 17 of 21
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Pressure – Measure
Hydraulic
Pneumatic
Vacuum
Up to 29 000 psi
Up to 10 000 psi
Down to -32 in Hg
0.02 % Full Scale
0.01 % Full Scale
0.017 in Hg + 0.6R
Fluke RPM4-E-DWT
Fluke 8370A
Fluke RPM4
Torque Wrenches
Up to 20 ozf∙in
Up to 100 ozf∙in
Up to 320 ozf∙in
Up to 50 lbf∙in
Up to 100 lbf∙in
Up to 100 lbf∙ft
Up to 1000 lbf∙ft
0.1 % of rdg
0.55 % of rdg
0.1 % of rdg
0.55 % of rdg
0.1 % of rdg
0.1 % of rdg
0.1 % of rdg
Model TSD6500-3 indicator
with TSD011 torque
transducer, CDI Model 1001-
O-DTT 501-I-DTT torque
tester
AKO TSD2060 pro torque
system
Torque Tester
Up to 800 lbf·ft
Up to 2000 lbf∙ft
0.1 % Full Scale
0.1 % Full Scale
Model TSD6500-1 indicator
with TSD821 torque
transducer
Model TSD1200 indicator
with TSD2021 torque
transducer | to 29000 psi |
| 18 | ASTM Class 1 mass standards | - | See scope document |
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 19 of 21
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Air Data Test Set
Pressure – Measure
Static (PS)
Dynamic – Pitot (Pt)
(0 to 32) InHg
(0 to 1080) mBar
108 kPa
(0 to 90) InHg
Up to 3050 mBar
305 kPa
0.003 inHg
0.14 mBar
0.014 kPa
0.009 inHg
0.32 mBar
0.032 kPa
Fluke RPM4
VIII. Optical Quantities
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Photometric – Measure
Luminance
(10 to 3000) cd/m2
2.7 % of rdg + 1
digit
Comparison with LS-110
luminance meter
IX. Thermodynamics
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature – Measuring
Equipment
(-30 to 660) °C
0.058 °C
SPRT with 8508A
Temperature – Measure
(-30 to 660) °C
0.058 °C
SPRT with 8508A
Infrared Temperature –
Measure
(1000 to 1400) °C
(4.5 + 0.6R) °C
Land 100B infrared
thermometer
ɛ =1.0, wavelength 1 µm
Relative Humidity –
Measuring Equipment
(10 to 80) % RH
1.3 % RH
Humidity generator -
Kaymont 2000SPA-X | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 20 of 21
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Relative Humidity –
Measure
(10 to 95) % RH
1.1 % RH
Thermo hygrometer
Kaymont KPPRHT-A-
1/S/R
X. Time & Frequency
Parameter/Range
Range
CMC2, 7 (±)
Comments
Frequency – Generate
250 kHz to 20 GHz
10 Hz up to 1 kHz
(> 1 to 10) kHz
(> 10 to 50) kHz
(> 50 to 100) kHz
> 100 kHz to 1 GHz
(> 1 to 4) GHz
0.000 69 µHz/Hz
0.000 64 Hz
0.000 89 Hz
0.0026 Hz
0.0048 Hz
0.046 µHz/Hz
0.048 µHz/Hz
Agilent E8257D
Fluke 9640A-LPN w/
9640A leveling head
Frequency – Measure
DC to 350 MHz
300 MHz to 15 GHz
0.12 µHz/Hz
0.12 µHz/Hz
Agilent 53230A
Agilent 53230A (opt
115)
Timers & Stopwatch
Up to 24 Hrs
0.067 s
Agilent 53132A
Tachometer – Optical
(150 to 6000) rpm
(6000 to 90 000) rpm
0.035 rpm
0.35 rpm
Keysight 53230A
universal counter with
GenRad 1538-A
stroboscope
___________________________________________
1 This laboratory offers commercial calibration service and dimensional testing service
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a labora tory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due up to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | 10 to 95 % RH |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 21 of 21
3 The measurand stated are generated with the Fluke 5720A series of instruments. The capability is suitable
for the calibration of the devices intended up to measure the stated measurand in the ranges indicated.
Calibration and Measurement Capabilities (CMC) are expressed as either a specific value that covers the
full range or as a combination of the fraction or percent of the reading/output plus a range specification.
4 The measurand stated are measured with the Fluke 732B and/or Agilent 3458A series of instruments. The
capability is suitable for the calibration of the devices intended up to measure the stated measurand in the
ranges indicated. Calibration and Measurement Capabilities (CMC) are expressed as either a specific
value that covers the full range , as a combination of the fraction or percent of the reading/output plus a
range specification. CMCs provided in % represent per cent of reading unless otherwise indicated as %
of Full Scale.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and R is the resolution of the unit under test.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification. | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
METROLOGY LABORATORY SAUDIA TECHNIC
Jeddah, SAUDI ARABIA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 12th day of February 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3211.01
Valid to March 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.