Saudi Arabia

Metrology Laboratory Saudia Technic

King AbdulAziz International Airport, Building 202, Saudia Technic, Jeddah, 21231, Saudi Arabia, Jeddah, Saudi Arabia

Visit website
A2LA 3211.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 22 scope lines.

A2LA certificate 3211.01 · 22 lines

LineMethodMatrixRange
1-Conductivity solutions
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 1 of 21 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 METROLOGY LABORATORY SAUDIA TECHNIC King Abdulaziz International Airport, Building 202. PO Box 167 CC: 833, Jeddah, Saudi Arabia 21231 Sami Kharmi Phone: +966 12 272 9001 ext. 833004 CALIBRATION Valid Until: March 31, 2026 Certificate Number: 3211.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Acoustic Quantities Parameter/Range Frequency CMC2, 7 (±) Comments Sound Measuring Equipment – Acoustical Level 114 dB, Fixed Points 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 0.63 dB 0.63 dB 0.43 dB 0.63 dB 0.63 dB GenRad 1562A II. Chemical Parameter/Equipment Range CMC2, 5 (±) Comments Conductivity Meters 1413 µS/cm 8.2 + 0.6R µS/cm Conductivity solutions pH Meters 4 pH 7 pH 10 pH 1.2e-02 pH + 0.6R 1.2e-02 pH + 0.6R 1.2e-02 pH + 0.6R pH buffer solutions
See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 2 of 21 III. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Micrometers Up to 50 in (1.86 + 5L) µin + 0.6R Gage blocks Calipers Up to 70 in (2.0 + 1.84L) µin + 0.6R Gage blocks Length Indicators (Dial, Test, Transducers) Up to 1.0 in Up to 6.0 in 0.000 12 in (3.0 + 1.5L) µin + 0.6R Indicator calibrator, gage blocks Heights Gages Up to 40 in (0.35 + 1.95L) µin + 0.6R Gage blocks Linear Measure (Milling Machines, CNC, etc.) Up to 4 in 0.9 µin/in + 0.6R Agilent 5519B laser system with weather station Crimping Tools Up to 0.500 in (Go-No Go Requirements) 0.000 11 in Pin gages Optical Flats Up to 6 in 4 µin Optical flats Levels Up to 90° 0.05° Angle blocks, gage blocks, surface plate Surface Plates Up to 87 in (diagonal length) 0.368 + 0.345DL µin Agilent 5519B laser system with weather station
to 50 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 3 of 21 IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3, 4, 8 (±) Comments DC Voltage – Generate Fixed Points 1.018 V 10.000 V (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 3.1 µV/V 2.4 µV/V 8.9 µV/V + 0.4 µV 5.8 µV/V + 0.7 µV 4.2 µV/V + 2.5 µV 4.3 µV/V + 4.0 µV 5.9 µV/V + 40 µV 7.6 µV/V + 0.4 mV Fluke DC voltage standard 732B with Agilent 3458A opt 002 Fluke 5720A/5725A with Agilent 3458A opt 002 DC Voltage – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 5.8 µV/V + 0.3 µV 4.6 µV/V + 0.3 µV 4.6 µV/V + 0.5 µV 6.9 µV/V + 30 µV 7.0 µV/V + 100 µV Agilent 3458A opt 002 with Fluke 5720A DC Current – Generate Clamp Meters (0 to 220) μA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A (10 to < 16.5) A (16.5 to < 150) A (150 to 1000) A 47 µA/A + 6.0 nA 41 µA/A + 7.0 nA 42 µA/A + 40 nA 53 µA/A + 0.7 µA 95 µA/A + 12 µA 420 µA/A + 480 µA 1.2 mA/A + 750 µA 7.8 mA/A + 0.02 A 5.8 mA/A + 0.14 A 5.8 mA/A + 0.50 A Fluke 5720A/5725A with Agilent 3458A opt 002 Fluke 5720A/5725A with Fluke 8508A Fluke 5522A Fluke 5522A with Fluke 5500A coil DC Current – Measure (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 2) A (2 to 20) A 24 µA/A + 0.1 nA 23 µA/A + 0.8 nA 23 µA/A + 5 nA 23 µA/A + 50 nA 40 µA/A + 0.5 µA 130 µA/A + 10 µA 200 µA/A + 16 µA 440 µA/A + 400 µA Agilent 3458A opt 002 Fluke 8508A
to 1100 V
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 4 of 21 Parameter/Equipment Range CMC2, 8 (±) Comments DC Power – Generate 0.01 mW to 21 kW 33 mV to 1020 V (0.33 to 329.99) mA (0.33 to 2.9999) A (3 to 20.5) A 0.33 mW/W 0.33 mW/W 0.86 mW/W Fluke 5522A Parameter/Range Frequency CMC2, 3, 8 (±) Comments AC Voltage – Generate (0 to 2.2) mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 720 µV/V + 4 µV 650 µV/V + 4 µV 650 µV/V + 4 µV 940 µV/V + 4 µV 1.3 mV/V + 5 µV 2.2 mV/V + 10 µV 4.1 mV/V + 20 µV 3.2 mV/V + 20 µV 300 µV/V + 4 µV 140 µV/V + 4 µV 130 µV/V + 4 µV 260 µV/V + 4 µV 600 µV/V + 5 µV 1.3 mV/V + 10 µV 1.7 mV/V + 20 µV 3.5 mV/V + 20 µV 280 µV/V + 12 µV 110 µV/V + 7 µV 95 µV/V + 7 µV 240 µV/V + 7 µV 540 µV/V + 17 µV 1.0 mV/V + 20 µV 1.6 mV/V + 25 µV 3.2 mV/V + 45 µV 280 µV/V + 40 µV 100 µV/V + 15 µV 55 µV/V + 8 µV 89 µV/V + 10 µV 130 µV/V + 30 µV 490 µV/V + 80 µV 1.2 mV/V + 200 µV 2.1 mV/V + 300 µV Fluke 5720A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 5 of 21 Parameter/Range Frequency CMC2, 3, 4, 8 (±) Comments AC Voltage – Generate (cont) (2.2 to 22) V (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz 280 µV/V + 400 µV 110 µV/V + 150 µV 55 µV/V + 50 µV 89 µV/V + 100 µV 120 µV/V + 200 µV 340 µV/V + 600 µV 1.2 mV/V + 2000 µV 2.0 mV/V + 3200 µV 280 µV/V + 4 mV 100 µV/V + 1.5 mV 64 µV/V + 0.6 mV 95 µV/V + 1 mV 180 µV/V + 2.5 mV 1.0 mV/V + 16 mV 0.11 mV/V + 4 mV 0.19 mV/V + 6 mV 0.70 mV/V + 11 mV Fluke 5720A Fluke 5720A/5725A AC Voltage – Measure Up to 10 mV (10 to 100) mV 100 mV to 1 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 350 µV/V + 3 µV 230 µV/V + 1.1µV 350 µV/V + 1.1µV 1.2 mV/V + 1.1µV 5.8 mV/V + 1.1µV 46 mV/V + 2 µV 84 µV/V + 4 µV 84 µV/V + 2 µV 160 µV/V + 2 µV 350 µV/V + 2 µV 920 µV/V + 2 µV 3.5 mV/V + 10 µV 12 mV/V + 10 µV 82 µV/V + 40 µV 82 µV/V + 20 µV 160 µV/V + 20 µV 350 µV/V + 20 µV 920 µV/V + 20 µV 3.5 mV/V + 100 µV 12 mV/V + 100 µV Agilent 3458A opt 002
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 6 of 21 Parameter/Range Frequency CMC2, 4, 8 (±) Comments AC Voltage – Measure (cont) (1 to 10) V (10 to 100) V (100 to 700) V (200 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz 84 µV/V + 0.4 mV 82 µV/V + 0.2 mV 160 µV/V + 0.2 mV 350 µV/V + 0.2 mV 920 µV/V + 0.2 mV 3.5 mV/V + 1 mV 12 mV/V + 1 mV 230 µV/V + 4 mV 230 µV/V + 2 mV 230 µV/V + 2 mV 400 µV/V + 2 mV 1.4 mV/V + 2 mV 4.6 mV/V + 10 mV 460 µV/V + 40 mV 460 µV/V + 20 mV 690 µV/V + 20 mV 1.4 mV/V + 20 mV 160 µV/V + 40 mV 130 µV/V + 20 mV 110 µV/V + 20 mV 250 µV/V + 20 mV Agilent 3458A opt 002 Fluke 8508A AC Current – Measure Up to 100 μA 100 µA to 1 mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz 4.6 mA/A + 30 nA 1.7 mA/A + 30 nA 690 µA /A + 30 nA 690 µA /A + 30 nA 4.6 mA/A + 0.2 µA 1.7 mA/A + 0.2 µA 690 µA/A + 0.2 µA 350 µA/A + 0.2 µA 690 µA/A + 0.2 µA 4.6 mA/A + 2 µA 1.7 mA/A + 2 µA 690 µA/A + 2 µA 350 µA/A + 2 µA 690 µA/A + 2 µA Agilent 3458A opt 002
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 7 of 21 Parameter/Range Frequency CMC2, 3, 4, 8 (±) Comments AC Current – Measure (cont) (10 to 100) mA 100 mA to 1 A (1 to 2) A (2 to 20) A (10 up to 20) Hz (20 up to 45) Hz (45 up to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (10 to 2) kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 4.6 mA/A + 20 µA 1.7 mA/A + 20 µA 690 µA/A + 20 µA 350 µA/A + 20 µA 690 µA/A + 20 µA 4.6 mA/A + 200 µA 1.9 mA/A + 200 µA 0.93 mA/A + 200 µA 1.2 mA/A + 200 µA 3.5 mA/A + 200 µA 700 µA/A + 0.2 mA 930 µA/A + 0.2 mA 930 µA/A + 2 mA 2.9 mA/A + 2 mA Agilent 3458A opt 002 Fluke 8508A AC Current – Generate Up to 220 μA 220 µA to < 2.2 mA (2.2 to < 22) mA (22 to < 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 310 µA/A + 16 nA 210 µA/A + 10 nA 170 µA/A + 8 nA 340 µA/A + 12 nA 1.3 mA/A + 65 nA 300 µA/A + 40 nA 200 µA/A + 35 nA 160 µA/A + 35 nA 240 µA/A + 110 nA 1.2 mA/A + 650 nA 300 µA/A + 40 nA 200 µA/A + 35 nA 150 µA/A + 35 nA 240 µA/A + 550 nA 1.3 mA/A + 5000 nA 300 µA/A + 4.0 µA 200 µA/A + 3.5 µA 150 µA/A + 2.5 µA 240 µA/A + 3.5 µA 1.3 mA/A + 10 µA Fluke5720A/5725A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 8 of 21 Parameter/Range Frequency CMC2, 3, 8 (±) Comments AC Current – Generate (cont) 220 mA to < 2.2 A (2.2 A to < 11) A Up to 330 μA 330 μA to < 3 mA (3 to < 33) mA (33 to < 330) mA 330 mA to < 1.1 A (1.1 A to < 3) A 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.31 mA/A + 35 µA 0.53 mA/A + 80 µA 8.1 mA/A + 160 µA 0.53 mA/A + 170 µA 1.1 mA/A + 380 µA 4.2 mA/A + 750 µA 3.2 mA/A + 0.1 µA 2.8 mA/A + 0.1 µA 2.0 mA/A + 0.1 µA 4.3 mA/A + 0.15 µA 10 mA/A + 0.2 µA 21 mA/A + 0.4 µA 1.5 mA/A + 0.15 µA 1.2 mA/A + 0.15 µA 2.3 mA/A + 0.2 µA 5.8 mA/A + 0.3 µA 12 mA/A + 0.6 µA 2.1 mA/A + 2 µA 1.0 mA/A + 2 µA 0.5 mA/A + 2 µA 0.9 mA/A + 2 µA 2.3 mA/A + 3 µA 4.7 mA/A + 4 µA 2.1 mA/A + 20 µA 1.0 mA/A + 20 µA 0.5 mA/A + 20 µA 1.2 mA/A + 50 µA 2.3 mA/A + 100 µA 4.6 mA/A + 200 µA 2.1 mA/A + 0.1 mA 2.1 mA/A + 0.1 mA 0.6 mA/A + 0.1 mA 6.9 mA/A + 1 mA 29 mA/A + 5 mA 2.1 mA/A + 0.1 mA 0.8 mA/A + 0.1 mA 6.9 mA/A + 1 mA 29 mA/A + 5 mA Fluke 5720A/5725A Fluke 5522A
0.00033 to 11 A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 9 of 21 Parameter/Range Frequency CMC2, 3, 8 (±) Comments AC Current – Generate (cont) (3 to < 11) A (11 to < 20.5) A Current Clamps – Toroidal (10 to < 16.5) A (16.5 to < 150) A (150 to 1000) A Non-Toroidal (10 to < 16.5) A (16.5 to < 150) A (150 to 1000) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.7 mA/A + 2 mA 1.2 mA/A + 2 mA 3.5 mA/A + 2 mA 1.4 mA/A + 5 mA 1.8 mA/A + 5 mA 3.5 mA/A + 5 mA 4.9 mA/A + 0.003 A 11 mA/A + 0.003 A 3.3 mA/A + 0.025 A 9.2 mA/A + 0.027 A 3.2 mA/A + 0.09 A 9.1 mA/A + 0.1 A 7.5 mA/A + 0.03 A 13 mA/A + 0.03 A 6.5 mA/A + 0.25 A 12 mA/A + 0.25 A 6.5 mA/A + 0.9 A 12 mA/A + 0.9 A Fluke 5522A Fluke 5522A with Fluke 5500A coil Parameter/Equipment Range CMC2, 8 (±) Comments AC Power – Generate 0.01 mW to 21 kW 33 mV to 1020 V (45 to 65) Hz (0.33 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 3.8 mW/W 2.2 mW/W 1.0 mW/W 0.38 mW/W 0.78 mW/W 0.40 mW/W 0.30 mW/W 0.86 mW/W Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 10 of 21 Parameter/Equipment Range CMC2, 3, 4, 8 (±) Comments Resistance – Generate, Fixed Points Ranged 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω 330 Ω to 1.099 999 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.999 99) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 110 µΩ/Ω 110 µΩ/Ω 27 µΩ/Ω 27 µΩ/Ω 12 µΩ/Ω 12 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω 13 µΩ/Ω 13 µΩ/Ω 23 µΩ/Ω 25 µΩ/Ω 47 µΩ/Ω 56 µΩ/Ω 140 µΩ/Ω 48 µΩ/Ω + 1mΩ 41 µΩ/Ω + 1.5 mΩ 34 µΩ/Ω + 1.4 mΩ 33 µΩ/Ω + 2 mΩ 33 µΩ/Ω + 2 mΩ 33 µΩ/Ω + 20 mΩ 33 µΩ/Ω + 20 mΩ 33 µΩ/Ω + 0.2 Ω 34 µΩ/Ω + 0.2 Ω 38 µΩ/Ω + 2 Ω 37 µΩ/Ω + 2 Ω 71 µΩ/Ω + 30 Ω 150 µΩ/Ω + 50 Ω 300 µΩ/Ω + 2.5 kΩ 590 µΩ/Ω + 3.0 kΩ 3.5 mΩ/Ω + 100 kΩ 17 mΩ/Ω + 500 kΩ Fluke 5720A with Agilent 3458A opt 002 Fluke 5522A
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 11 of 21 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Resistance – Measure (0 to < 10) Ω (10 to < 100) Ω 100 Ω to < 1 kΩ (1 to < 10) kΩ (10 to < 100) kΩ 100 kΩ to 1 MΩ (1 to < 10) MΩ (10 to < 100) MΩ 100 MΩ to 1 GΩ 20 MΩ 200 MΩ 2 GΩ 20 GΩ 18 µΩ/Ω + 0.05 mΩ 14 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 5 mΩ 12 µΩ/Ω + 50 mΩ 19 µΩ/Ω + 2 Ω 70 µΩ/Ω + 0.1 kΩ 0.58 mΩ/Ω + 1 kΩ 5.8 mΩ/Ω + 10 kΩ 19 µΩ/Ω + 0.1 kΩ 73 µΩ/Ω + 1 kΩ 180 µΩ/Ω + 0.1 MΩ 610 µΩ/Ω + 0.01 GΩ Agilent 3458A Fluke 8508A Audio Distortion – Measure 20 Hz to 20 kHz (20 to 100) kHz 1.2 dB 2.3 dB Agilent 8903B Oscilloscope – DC 50 Ω Load 1 MΩ Load Square Wave (10 Hz to 10 kHz) 50 Ω Load 1 MΩ Load Level Sine Wave Flatness – 50 kHz Reference Frequency Time Marker – Generate (0 to + 6.6) V (0 to + 130) V (0.001 to + 6.6) V p-p (0.001 to + 130) V p-p 50 kHz to 100 MHz (100 to 300) MHz (300 to 500) MHz (500 to 600) MHz 2 ns, 5 ns 10 ns, 20 ns, 50 ns 100 ns, 200 ns, 500 ns 1 µs, 2 µs, 5 µs 10 µs, 20 µs, 50 µs 100 µs, 200 µs, 500 µs 1 ms, 2 ms, 5 ms 10 ms, 20 ms, 50 ms 100 ms, 200 ms, 500 ms 1s, 2s, 5s 0.29 % + 40 µV 0.029 % + 25 µV 0.29 % + 40 µV 0.058 % + 5 µV 2.2 % + 100 µV 2.7 % + 100 µV 4.3 % + 100 µV 4.8 % + 100 µV 0.000 58 ns 0.0058 ns 0.058 ns 0.000 58 µs 0.0058 µs 0.058 µs 0.000 58 ms 0.0058 ms 0.058 ms 0.000 82 s Fluke 5820A calibrator
to 1 GΩ
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 12 of 21 Parameter/Range Frequency CMC2, 8 (±) Comments Capacitance – Generate Fixed Points 10 pF 100 pF 100 pF 1 kHz 1 kHz 1 kHz 0.000 24 pF 0.0024 pF 0.024 pF GenRad 1404-C GenRad 1404-B ESI SC1000 (1.0 to 3.2999) nF (3.3 to 109.999) nF (110 to 329.999) nF (0.33 to 1.0999) µF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.999) μF (110 to 329.999) μF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.56 % + 0.01 nF 0.23 % + 0.01 nF 0.23 % + 0.3 nF 0.23 % + 1 nF 0.23 % + 3 nF 0.23 % + 10 nF 0.36 % + 30 nF 0.40 % + 100 nF 0.40 % + 300 nF 0.40 % + 1 μF 0.40 % + 3 μF 0.40 % + 10 μF 0.80 % + 30 μF 1.2 % + 100 μF Fluke 5522A Capacitance – Measure (1 to 1000) pF 1 pF to 200 µF 1 kHz 1 kHz 6.0 µF/F 0.30 % of rdg + 1 digit AH2700A ESI 252 Inductance – Generate, Fixed Points 1.0 mH 10.0 mH 100.0 mH (100 to 1000) µH (1 to 10) mH (10 to 100) mH (100 to 1000) mH (1 to 10) H 1 kHz 1 kHz 1 kHz 20 kHz 10 kHz 3 kHz 1 kHz 300 Hz 0.0012 mH 0.012 mH 0.12 mH 2.3 % of rdg 2.3 % of rdg 1.9 % of rdg 0.93 % of rdg 0.93 % of rdg GenRad 1482-E GenRad 1482-H GenRad 1482-L GenRad 1491-G Inductance – Measure 1 µH to 20 H 1 kHz 2.9 % of rdg + 1 digit ESI 252 LCR meter
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 13 of 21 Parameter/Range Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators – Type E Type J Type K Type R Type S Type T (-200 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-150 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1370) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (-160 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.58 °C 0.20 °C 0.18 °C 0.20 °C 0.25 °C 0.32 °C 0.20 °C 0.18 °C 0.21 °C 0.27 °C 0.39 °C 0.22 °C 0.20 °C 0.31 °C 0.47 °C 0.66 °C 0.41 °C 0.39 °C 0.47 °C 0.55 °C 0.42 °C 0.43 °C 0.54 °C 0.73 °C 0.29 °C 0.20 °C 0.18 °C Fluke 5522A calibrator Electrical Calibration of RTD Indicating System Pt 385, 100 Ω (-200 to -80) °C (> -80 to 0) °C (> 0 to 100) °C (> 100 to 300) °C (> 300 to 400) °C (> 400 to 630) °C (> 630 to 800) °C 0.058 °C 0.058 °C 0.081 °C 0.10 °C 0.12 °C 0.14 °C 0.27 °C Fluke 5522A calibrator
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 14 of 21 V. Electrical – RF/Microwave Parameter/Equipment Frequency CMC2, 5, 8 (±) Comments Amplitude Modulation – Measure Rate: 50 Hz to 10 kHz Depth: (5 to 99) % Rate: 20 Hz to 10 kHz Depth: 99 % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 20 Hz to 100 kHz Depth: 99 % 150 kHz to 10 MHz 150 kHz to 10 MHz (10 to 1300) MHz (10 to 1300) MHz 2.4 % of rdg + 1 digit 3.4 % of rdg + 1 digit 1.2 % of rdg + 1 digit 3.5 % of rdg + 1 digit HP 8902A Frequency Modulation – Measure Rate: 20 Hz to 10 kHz Depth: < 40 kHz Peak Rate: 50 Hz to 100 kHz Depth: < 400 kHz Peak Rate: 20 Hz to 200 kHz Depth: < 400 kHz Peak 150 kHz to 10 MHz (10 to 1300) MHz (10 to 1300) MHz 2.3 % of rdg + 1 digit 1.2 % of rdg + 1 digit 5.8 % of rdg + 1 digit HP 8902A Fixed Attenuators – Measure 3 dB 6 dB 10 dB 20 dB 30 dB 50 MHz to 18 GHz 2.7 % of rdg 2.7 % of rdg 2.7 % of rdg 2.7 % of rdg 2.7 % of rdg Agilent E9327A w/ E4416A RF Power Level – Generate (-90 to < -70) dBm (-70 to < -10) dBm (-10 to 16) dBm (> 16 to 20) dBm (-90 to < -70) dBm (-70 to < -10) dBm (-10 to 20) dBm 250 kHz to 2 GHz (2 to 20) GHz 0.95 dBm 0.84 dBm 0.73 dBm 0.94 dBm 1.2 dBm 1.1 dBm 0.95 dBm Agilent E8257D
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 15 of 21 Parameter/Equipment Frequency CMC2, 5, 8 (±) Comments RF Power Level – Generate (cont) (> 20 to 24) dB (> 14 to 20) dB (-17 to 14) dB (-48 to ≤ -17) dB (> -74 to < -48) dB (> -94 to -74) dB (-130 to -94) dB (> +14 to +20) dB (-17 to 14) dB (-48 to ≤ -17) dB (> -74 to < -48) dB (> -94 to -74) dB (-130 to -94) dB (> 14 to 20) dB (-17 to 14) dB (-48 to ≤ -17) dB (> -74 to < -48) dB (> -94 to -74) dB (-130 to -94) dB (-17 to 14) dB (-48 to ≤ -17) dB (> -60 to < -48) dB (-17 to 14) dB (-48 to ≤ -17) dB (> -60 to < -48) dB > 100 kHz to 125 MHz (> 125 to 300) MHz > 300 MHz to 1.4 GHz (> 1.4 to 3) GHz (> 3 to 4) GHz 0.063 dB 0.062 dB 0.063 dB 0.063 dB 0.23 dB 0.58 dB 1.7 dB 0.12 dB 0.12 dB 0.12 dB 0.24 dB 0.58 dB 1.8 dB 0.29 dB 0.29 dB 0.58 dB 0.58 dB 1.2 dB 1.8 dB 0.36 dB 0.58 dB 0.59 dB 0.37 dB 0.59 dB 0.59 dB Fluke 9640A-LPN with Fluke 9640A-50 leveling head
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 16 of 21 Parameter/Equipment Frequency CMC2, 5, 8 (±) Comments RF Power Level – Measure Absolute Measure (-60 to 0) dBm (> 0 to 20) dBm Relative Measure (-20 to 20) dB Tuned RF Power- (-127 to < -120) dB (-120 to 0) dB 50 MHz to < 1 GHz (1 to < 7) GHz (7 to < 14) GHz (14 to < 18) GHz 50 MHz to < 1 GHz (1 to < 7) GHz (7 to < 14) GHz (14 to < 18) GHz 100 kHz to 2.6 GHz 2.5 MHz to 1.3 GHz 2.1 % of rdg 2.5 % of rdg 2.7 % of rdg 3.0 % of rdg 2.4 % of rdg 2.7 % of rdg 2.9 % of rdg 3.2 % of rdg 0.082 dB 0.38 dB 0.18 dB Agilent E9327A with power meter HP 8902A with 11722A VI. Fluid Quantities Parameter/Equipment Range CMC2, 7 (±) Comments Flow – Measuring Fluid Flow Meters Up to 0.25 GPM Up to 160 GPM 0.6 % of rdg 0.36 % of rdg FTS FT series flow meters VII. Mechanical Parameter/Equipment Range CMC2, 7 (±) Comments Force – Measuring Equipment Up to 30 000 lbf Up to 100 000 lbf 3 lbf 7.5 lbf Morehouse series 200 proving rings with digital readout
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 17 of 21 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Pressure – Measure Hydraulic Pneumatic Vacuum Up to 29 000 psi Up to 10 000 psi Down to -32 in Hg 0.02 % Full Scale 0.01 % Full Scale 0.017 in Hg + 0.6R Fluke RPM4-E-DWT Fluke 8370A Fluke RPM4 Torque Wrenches Up to 20 ozf∙in Up to 100 ozf∙in Up to 320 ozf∙in Up to 50 lbf∙in Up to 100 lbf∙in Up to 100 lbf∙ft Up to 1000 lbf∙ft 0.1 % of rdg 0.55 % of rdg 0.1 % of rdg 0.55 % of rdg 0.1 % of rdg 0.1 % of rdg 0.1 % of rdg Model TSD6500-3 indicator with TSD011 torque transducer, CDI Model 1001- O-DTT 501-I-DTT torque tester AKO TSD2060 pro torque system Torque Tester Up to 800 lbf·ft Up to 2000 lbf∙ft 0.1 % Full Scale 0.1 % Full Scale Model TSD6500-1 indicator with TSD821 torque transducer Model TSD1200 indicator with TSD2021 torque transducer
to 29000 psi
18ASTM Class 1 mass standards-See scope document
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 19 of 21 Parameter/Equipment Range CMC2, 7 (±) Comments Air Data Test Set Pressure – Measure Static (PS) Dynamic – Pitot (Pt) (0 to 32) InHg (0 to 1080) mBar 108 kPa (0 to 90) InHg Up to 3050 mBar 305 kPa 0.003 inHg 0.14 mBar 0.014 kPa 0.009 inHg 0.32 mBar 0.032 kPa Fluke RPM4 VIII. Optical Quantities Parameter/Equipment Range CMC2, 7 (±) Comments Photometric – Measure Luminance (10 to 3000) cd/m2 2.7 % of rdg + 1 digit Comparison with LS-110 luminance meter IX. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measuring Equipment (-30 to 660) °C 0.058 °C SPRT with 8508A Temperature – Measure (-30 to 660) °C 0.058 °C SPRT with 8508A Infrared Temperature – Measure (1000 to 1400) °C (4.5 + 0.6R) °C Land 100B infrared thermometer ɛ =1.0, wavelength 1 µm Relative Humidity – Measuring Equipment (10 to 80) % RH 1.3 % RH Humidity generator - Kaymont 2000SPA-X
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 20 of 21 Parameter/Equipment Range CMC2, 7 (±) Comments Relative Humidity – Measure (10 to 95) % RH 1.1 % RH Thermo hygrometer Kaymont KPPRHT-A- 1/S/R X. Time & Frequency Parameter/Range Range CMC2, 7 (±) Comments Frequency – Generate 250 kHz to 20 GHz 10 Hz up to 1 kHz (> 1 to 10) kHz (> 10 to 50) kHz (> 50 to 100) kHz > 100 kHz to 1 GHz (> 1 to 4) GHz 0.000 69 µHz/Hz 0.000 64 Hz 0.000 89 Hz 0.0026 Hz 0.0048 Hz 0.046 µHz/Hz 0.048 µHz/Hz Agilent E8257D Fluke 9640A-LPN w/ 9640A leveling head Frequency – Measure DC to 350 MHz 300 MHz to 15 GHz 0.12 µHz/Hz 0.12 µHz/Hz Agilent 53230A Agilent 53230A (opt 115) Timers & Stopwatch Up to 24 Hrs 0.067 s Agilent 53132A Tachometer – Optical (150 to 6000) rpm (6000 to 90 000) rpm 0.035 rpm 0.35 rpm Keysight 53230A universal counter with GenRad 1538-A stroboscope ___________________________________________ 1 This laboratory offers commercial calibration service and dimensional testing service 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a labora tory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due up to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
10 to 95 % RH
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3211.01) Revised 03/20/2024 Page 21 of 21 3 The measurand stated are generated with the Fluke 5720A series of instruments. The capability is suitable for the calibration of the devices intended up to measure the stated measurand in the ranges indicated. Calibration and Measurement Capabilities (CMC) are expressed as either a specific value that covers the full range or as a combination of the fraction or percent of the reading/output plus a range specification. 4 The measurand stated are measured with the Fluke 732B and/or Agilent 3458A series of instruments. The capability is suitable for the calibration of the devices intended up to measure the stated measurand in the ranges indicated. Calibration and Measurement Capabilities (CMC) are expressed as either a specific value that covers the full range , as a combination of the fraction or percent of the reading/output plus a range specification. CMCs provided in % represent per cent of reading unless otherwise indicated as % of Full Scale. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches and R is the resolution of the unit under test. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
22

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited METROLOGY LABORATORY SAUDIA TECHNIC Jeddah, SAUDI ARABIA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 12th day of February 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3211.01 Valid to March 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.