MeßTechnikNord
Prüssingstraße 41, 07745, Jena, Germany
Visit website- Accredited standards
- 1
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 6789-2Assembly tools for screws and nuts - Hand torque tools - Part 2: Requirements for calibration and determination of measurement uncertainty
DIN EN ISO 6789- 2:2017; ISO 6789- 2:2017; EN ISO 6789- 2:2017
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-15086-02-01
Accredited scope, certificate D-PL-15086-02-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | - | Pressure; Torque; Weighing instruments; Temperature quantities; Direct reading thermometers; Humidity quantities; Devices for relative humidityShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Partial Accreditation Certificate D-K-15086-01-02
Valid from: 27.02.2025
Date of issue: 27.02.2025 Page 2 of 4
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
Calibration in the fields:
Mechanical quantities
− Pressure
− Torque
− Weighing instruments a)
Thermodynamic quantities
Temperature quantities
− Direct reading thermometers
Humidity quantities
− Devices for relative humidity
a) only on-site calibration
Within the measurands/calibration items marked with * the calibration laboratory is permitted, without
being required to inform and obtain prior approval from DAkkS, to use calibration standards or
equivalent calibration procedures listed here with different issue dates.
The calibration laboratory maintains a current list of all calibration standards / equivalent calibration
procedures within the flexible scope of accreditation. | - |
| 3 | DIN EN ISO 6789- 2:2017; ISO 6789- 2:2017; EN ISO 6789- 2:2017 | - | See scope document |
| 4 | EURAMET Calibration Guide No. 18 Version 4.0 (11/2015) | - | to 10 kg |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-15086-02-02
Accredited scope, certificate D-PL-15086-02-02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | - | Pressure; Torque; Weighing instruments; Temperature quantities; Direct reading thermometers; Humidity quantities; Devices for relative humidityShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Partial Accreditation Certificate D-K-15086-01-02
Valid from: 27.02.2025
Date of issue: 27.02.2025 Page 2 of 4
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
Calibration in the fields:
Mechanical quantities
− Pressure
− Torque
− Weighing instruments a)
Thermodynamic quantities
Temperature quantities
− Direct reading thermometers
Humidity quantities
− Devices for relative humidity
a) only on-site calibration
Within the measurands/calibration items marked with * the calibration laboratory is permitted, without
being required to inform and obtain prior approval from DAkkS, to use calibration standards or
equivalent calibration procedures listed here with different issue dates.
The calibration laboratory maintains a current list of all calibration standards / equivalent calibration
procedures within the flexible scope of accreditation. | - |
| 3 | DIN EN ISO 6789- 2:2017; ISO 6789- 2:2017; EN ISO 6789- 2:2017 | - | See scope document |
| 4 | EURAMET Calibration Guide No. 18 Version 4.0 (11/2015); OIML R 111-1:2004 | Nonautomatic weighing instruments | to 10 kg |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.