Elevated Industrial Solutions
1201 E. Whitcomb, 48071, Madison Heights, MI, United States
Visit website- Scope lines
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 2 scope lines.
A2LA certificate 1522.01 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1522.01) 7/23/2025 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
ELEVATED INDUSTRIAL SOLUTIONS
1201 E. Whitcomb
Madison Heights, MI 48071
Jim Casey Phone: 248 619 7800
CALIBRATION
Valid To: July 31, 2027 Certificate Number: 1522.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Mechanical
Parameter/Equipment
Range CMC2 (±) Comments
Torque Tools3
(1 to 20) N·m
(20 to 180) N·m
(180 to 800) N·m
0.03 N·m + 2 % of rdg
0.03 N·m + 2 % of rdg
4.1 N·m + 1.7 % of rdg
Torque transducer
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 2 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.