HYDRO-CHART
7709 E 42ND PL, STE 104, 74145, TULSA, OK, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 6145.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; R205 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6145.01) 05/16/2025 Page 2 of 2
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature –
Measuring Instruments
(40 to 120) °F
0.19 °F
Digital thermometer with
PRT
________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing routine calibrations of
nearly ideal measurement standards or nearly id eal measuring equipment. CMCs represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | 40 to 120 °F |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.