MOBILNE Laboratorium Techniki Budowlanej
ul. Wrocławska 142B, 58-306, Wałbrzych, Poland
Visit website- Accredited standards
- 31
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 31 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
EN14
EN 514
EN 948
EN 1026
EN 1027
EN 1628
EN 1629
EN 1630
EN 12046-1
EN 12046-2
EN 12211
EN 13051
EN 14351-1
EN 14608
EN 14609
ASTM9
ASTM E283
ASTM E330
ASTM E331
ASTM E547
ASTM E987
ASTM E1886
ASTM E1996
ASTM E2068
ASTM F588
ISO4
ISO 717-1Acoustics - Rating of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation
ISO 10077-1Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General
ISO 10077-2Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
ISO 12631Thermal performance of curtain walling - Calculation of thermal transmittance
ISO 10140 series4
ISO 10140-1Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products
ISO 10140-2Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation
ISO 10140-4Acoustics - Laboratory measurement of sound insulation of building elements - Part 4: Measurement procedures and requirements
ISO 10140-5Acoustics - Laboratory measurement of sound insulation of building elements - Part 5: Requirements for test facilities and equipment
PN-EN 1026:2016; PN-EN 1027:2016; PN-EN 514:2018-02; PN-EN ISO 10077-1:2017-10; PN-EN ISO 10077-2:2017-10; PN-EN 12211:2016; PN-EN 14351-1+A2:2016; PN-EN 14609:2006; PN-EN 12046-1:2021-02; PN-EN 14608:2006; PN-EN 12046-2:2001; PN-EN 948:2000; PN-EN ISO 12631:2017-10
PN-EN 1026:2016; PN-EN 1027:2016; PN-EN 12211:2016; PN-EN 14609: 2006; PN-EN 14351-1+A2:2016; PN-EN 12046-1:2021-02; PN-EN 14608:2006; PN-EN 12046-2:2001; PN-EN 948:2000; PN-EN 13051:2004
PN-EN 1628:2011; PN-EN 1628:2021-11; PN-EN 1629:2011; PN-EN 1629:2021-11; PN-EN 1630:2011; PN-EN 1630:2021-11; PN-EN ISO 10140-1:2016-10; PN-EN ISO 10140-1:2021-10; PN-EN ISO 10140-2:2011; PN-EN ISO 10140-2:2021-10; PN-EN ISO 10140-4:2011; PN-EN ISO 10140-4:2021-10; PN-EN ISO 10140-5:2011; PN-EN ISO 10140-5:2011/A1: 2014-09; PN-EN ISO 10140-5:2021-10; PN-EN ISO 717-1:2021-06; ASTM E330/E330M-14 (2021); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; ASTM E283/E283M-19; CSA A440S1:19; CSA A440S1:25; ASTM E331-00 (2016); ASTM E547-00 (2016); ASTM E2068-00 (2022)
EN 14351-1:2006+A2:2016
ASTM E987-88 (2017); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; ASTM F588-17 (2023); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440-17
ASTM E1996-23; ASTM E1886-19; Testing Application Standard (Tas) 201-94; Testing Application Standard (Tas) 202-94; Testing Application Standard (Tas) 203-94
EN ISO 10140-1:2021-10; Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
8 lines
ISO/IEC 17025
ActiveAB 1054
The scope document we hold says it is valid until 2029-06-16.
Accredited scope, certificate AB 1054
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | EU Regulation No 305/2011 (CPR); EC decisions 99/93/WE | building products | - |
| 2 | PN-EN 1026:2016; PN-EN 1027:2016; PN-EN 514:2018-02; PN-EN ISO 10077-1:2017-10; PN-EN ISO 10077-2:2017-10; PN-EN 12211:2016; PN-EN 14351-1+A2:2016; PN-EN 14609:2006; PN-EN 12046-1:2021-02; PN-EN 14608:2006; PN-EN 12046-2:2001; PN-EN 948:2000; PN-EN ISO 12631:2017-10 | Okna; okiennice; drzwi balkonowe; drzwi; rolety; żaluzje; ściany; bramy; drzwi zewnętrzne; drzwi wewnętrzne; sekcje ram ścian osłonowych | See scope document |
| 3 | PN-EN 1628:2011; PN-EN 1628:2021-11; PN-EN 1629:2011; PN-EN 1629:2021-11; PN-EN 1630:2011; PN-EN 1630:2021-11; PN-EN ISO 10140-1:2016-10; PN-EN ISO 10140-1:2021-10; PN-EN ISO 10140-2:2011; PN-EN ISO 10140-2:2021-10; PN-EN ISO 10140-4:2011; PN-EN ISO 10140-4:2021-10; PN-EN ISO 10140-5:2011; PN-EN ISO 10140-5:2011/A1: 2014-09; PN-EN ISO 10140-5:2021-10; PN-EN ISO 717-1:2021-06; ASTM E330/E330M-14 (2021); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; ASTM E283/E283M-19; CSA A440S1:19; CSA A440S1:25; ASTM E331-00 (2016); ASTM E547-00 (2016); ASTM E2068-00 (2022) | Okna, drzwi, drzwi balkonowe; Drzwi zewnętrzne i wewnętrzne; Okna, okna dachowe, okiennice, żaluzje, szyby; Ściany zewnętrzne, ściany wewnętrzne, bramy i ich elementy; Ściany osłonowe; Elementy budowlane, wentylacyjne i inne obiekty o powierzchni mniejszej niż 1m2; Okna, drzwi zewnętrzne | 1.5 to 10 kN |
| 4 | ASTM E987-88 (2017); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; ASTM F588-17 (2023); AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440:22; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440-17; AAMA/WDMA/CSA 101/1.S.2/A440-17 | Okna; Drzwi zewnętrzne | See scope document |
| 5 | ASTM E1996-23; ASTM E1886-19; Testing Application Standard (Tas) 201-94; Testing Application Standard (Tas) 202-94; Testing Application Standard (Tas) 203-94 | Okna, drzwi zewnętrzne, ściany osłonowe; Windows, external doors, curtain walls; Okładziny ścienne, pustaki szklane, drzwi zewnętrzne, bramy garażowe, świetliki, okna, żaluzje przeciw-burzowe, inne elementy przegród zewnętrznych budynku; Wall cladding, glass block, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external component which help maintain the integrity of the building envelope | See scope document |
| 6 | PN-EN 1026:2016; PN-EN 1027:2016; PN-EN 12211:2016; PN-EN 14609: 2006; PN-EN 14351-1+A2:2016; PN-EN 12046-1:2021-02; PN-EN 14608:2006; PN-EN 12046-2:2001; PN-EN 948:2000; PN-EN 13051:2004 | Okna; okiennice; drzwi balkonowe i drzwi; rolety; żaluzje; ściany; bramy; drzwi wewnętrzne; drzwi zewnętrzne; ściany osłonowe | See scope document |
| 7 | EN 14351-1:2006+A2:2016 | - | - |
| 8 | EN ISO 10140-1:2021-10; Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.