Holco Metrology Solutions
407 West Elm Ave, 19454, North Wales, PA, United States
Visit website- Scope lines
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 2 scope lines.
A2LA certificate 2435.01 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2435.01) 4/9/2024 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
HOLCO METROLOGY SOLUTIONS, LLC
407 West Elm Ave
North Wales, PA 19454
John Lankford Phone: 814 599 1088
CALIBRATION
Valid To: April 30, 2026 Certificate Number: 2435.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Video Measuring
Systems3
Up to 8 in
(12 to 24) in
(42 + 0.17L) μin
(51 + 0.37L) μin
Glass grid and stair
step gage
Optical Comparators and
Contour Projectors3
Up to 18 in
69 μin
Comparator reticle
comparison
____________________________________________
1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for these calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | to 18 in |
| 2 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.