Anritsu Americas Sales Company

490 Jarvis Drive, 95037, Morgan Hill, CA, United States

Visit website
A2LA 2160.05ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 2160.05 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 ANRITSU AMERICAS SALES COMPANY 490-to 0.1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2160.05) 07/31/2024 Page 2 of 5 Parameter/Range Frequency CMC2, 5 (±) Comments Power Level – Absolute3, 8 Measure & Generate, Type N & K Connector, Spectrum Analyzer, Measuring Receiver (-35 to 20) dBm (-60 to 20) dBm (-90 to -60) (-35 to 20) dBm (-60 to 20) dBm (-90 to -60) (0.01 to 100) MHz (0.1 to 2) GHz (2 to 12) GHz (12 to 18) GHz (0.01 to 2) GHz (2 to 9) GHz (9 to 13) GHz (13 to 18) GHz (0.01 to 18) GHz (0.01 to 100) MHz (0.1 to 7) GHz (7 to 12) GHz (12 to 17) GHz (17 to 40) GHz (0.01 to 3) GHz (3 to 8) GHz (8 to 12) GHz (12 to 27) GHz (27 to 40) GHz (0.05 to 40) GHz 0.025 dB 0.030 dB 0.045 dB 0.055 dB 0.057 dB 0.063 dB 0.071 dB 0.088 dB 0.17 dB 0.035 dB 0.05 dB 0.06 dB 0.08 dB 0.085 dB 0.057 dB 0.063 dB 0.071 dB 0.088 dB 0.097 dB 0.18 dB Type N power sensor Spectrum analyzer, power sensor with attenuator Type K power sensor Spectrum analyzer, power sensor with attenuator Power Level – Absolute6 Measure & Generate, Type V & Waveguide Connector (-35 to 20) dBm (0.01 to 100) MHz (0.1 to 2) GHz (2 to 8) GHz (8 to 12) GHz (12 to 26) GHz (26 to 40) GHz (40 to 50) GHz (50 to 67) GHz 0.04 dB 0.05 dB 0.06 dB 0.065 dB 0.08 dB 0.09 dB 0.12 dB 0.17 dB Type V power sensor
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2160.05) 07/31/2024 Page 3 of 5 Parameter/Range Frequency CMC2, 5, 7 (±) Comments Power Level – Absolute6 Measure& Generate, Type V & Waveguide Connector (cont) (-35 to 20) dBm (50 to 90) GHz 0.21 dB Waveguide power sensor Frequency Modulation – Measure Modulation 10 % Carrier 1 GHz 5 GHz 10 GHz 20 GHz 30 GHz 40 GHz 0.02 % 0.08 % 0.15 % 0.30 % 0.45 % 0.60 % Function generator measuring receiver LO synthesizer Amplitude Modulation – Measure (10 to 100) % (1 to 20) GHz (20 to 40) GHz 2.6 % 3.9 % Function generator & measuring receiver Pulse Modulation – Measure Power Rise, Fall & Compression High Level Noise Magnitude High Level Noise Phase (0.01 to 40) GHz < 500 kHz (0.005 to 2.5) GHz (2.5 to 5) GHz (5 to 20) GHz (20 to 40) GHz < 500KHz (0.005 to 2.5) GHz (2.5 to 5) GHz (5 to 20) GHz (20 to 40) GHz 0.09 dB 0.011 ns 0.000 59 dB-rms 0.000 33 dB-rms 0.000 25 dB-rms 0.000 28 dB-rms 0.000 32 dB-rms 0.0055 deg-rms 0.0025 deg-rms 0.0029 deg-rms 0.0018 deg-rms 0.0028 deg-rms Wide band oscilloscope & function generator Spectrum & network analyzers
-35 to 20 dBm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2160.05) 07/31/2024 Page 4 of 5 III. Mechanical Parameter/Equipment Range CMC2, 7 (±) Comments Torque Wrench (0.25 to 250) lbf.in 2.5 % Torque analyzer IV. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment 10 MHz reference 1 Hz to 70 GHz4 9 x 10-11 Hz/Hz 1.4 x 10-9 Hz/Hz GPS receiver Synthesizer w/ GPS disciplined oscillator ____________________________________________ 1 This laboratory offers commercial calibration and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2160.05) 07/31/2024 Page 5 of 5 7 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 8 Enlisted values represent absolute power level uncertainty, including test port match.
6ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.