Schneider Electric Automation GmbH
Schneiderplatz 1, 97828, Marktheidenfeld, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Schneider Electric Automation GmbH?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-20648-01-01Active
- D-PL-20648-01-00Active
Accredited standards
25Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity testCertificate says EN 61000-4-2:2009. Probably the same standard; not checked against the EN document.
DIN EN 55016-2-1:2019-11; EN 55016-2-1:2014 + A1:2017; CISPR 16-2-1:2014-02 /COR1:2020-08; CISPR 16-2-1:2014-02 /AMD1:2017-06; CISPR 16-2-1:2014-02; DIN EN 61000-4-2:2009-12; EN 61000-4-2:2009; IEC 61000-4-2:2008
IEC 61000-4-2:2008-12; DIN EN 61000-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-4:2012-04; DIN EN 61000-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014-05/AMD1:2017-08; IEC 61000-4-5:2014-05
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity testCertificate says EN 61000-4-4:2012. Probably the same standard; not checked against the EN document.
IEC 61000-4-2:2008-12; DIN EN 61000-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-4:2012-04; DIN EN 61000-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014-05/AMD1:2017-08; IEC 61000-4-5:2014-05
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-2:2008-12; DIN EN 61000-4-4:2013-04; EN 61000-4-4:2012; IEC 61000-4-4:2012-04; DIN EN 61000-4-5:2019-03; EN 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014 + A1:2017; IEC 61000-4-5:2014-05/AMD1:2017-08; IEC 61000-4-5:2014-05
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
DIN EN 61000-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013-10 /AC1:2015-06; IEC 61000-4-6:2013-10; DIN EN IEC 61000-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-2:2016
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
DIN EN 61000-4-6:2014-08; EN 61000-4-6:2014; IEC 61000-4-6:2013-10 /AC1:2015-06; IEC 61000-4-6:2013-10; DIN EN IEC 61000-6-2:2019-11; EN IEC 61000-6-2:2019; IEC 61000-6-2:2016
IEC 61000-6-2:2016-08; NF EN IEC 61000-6-3:2021-03; EN 61000-6-3:2021-03; DIN EN 61000-6-3:2011-09
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
IEC 61000-6-2:2016-08; NF EN IEC 61000-6-3:2021-03; EN 61000-6-3:2021-03; DIN EN 61000-6-3:2011-09
DIN EN 61000-6-3; ELOT EN 61000-6-3; IEC 61000-6-3
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
DIN EN IEC 61000-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-4:2018-02; ELOT EN 61000-6-5 :2015-11 /AC:2018-01; EN 61000-6-5/AC:2018
IEC 61000-6-5Name not checked yet
DIN EN IEC 61000-6-4:2020-09; EN IEC 61000-6-4:2019; IEC 61000-6-4:2018-02; ELOT EN 61000-6-5 :2015-11 /AC:2018-01; EN 61000-6-5/AC:2018
EN 61000-6-5:2015-11; IEC 61000-6-5:2015-08
IEC 61000-6-5:2015-08; DIN EN 61000-6-7:2015-12
IEC 61000-6-7Name not checked yet
IEC 61000-6-5:2015-08; DIN EN 61000-6-7:2015-12
DIN EN 61000-6-7:2015-12; EN 61000-6-7:2015; IEC 61000-6-7:2014-10; DIN EN 55011:2022-05; EN 55011:2016 + A1:2017 + A11:2020 + A2:2021
IEC
IEC 61131-2Name not checked yet
DIN EN 61131-2 :2008-04 /Berichtigung 1:2009-01; EN 61131,2:2007; IEC 61131-2:2007; EN 61131-2:2007; DIN EN 61131-2 (VDE 0411-500):2008-04; 61000-4-2; 61000-4-4; 61000-4-5; 61000-4-6
DIN EN 61131-2:2008-04; EN 61131-2:2007; IEC 61131-2:2017-08
IEC 61326-3-1Name not checked yet
DIN EN 61326-3-1:2018-04; EN 61326-3-1:2017; IEC 61326-3-1:2017-05
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
DIN EN IEC 61800-3:2019-04; EN IEC 61800-3:2018; IEC 61800-3:2017; EN IEC 61800-3:2018; 61000-4-2; 61000-4-4; 61000-4-5; 61000-4-6
IEC 61800-3:2017-02; 61000-4-2; 61000-4-4; 61000-4-5; 61000-4-6
IEC 61800-5-2Name not checked yet
DIN EN 61800-5-2:2017-11; EN 61800-5-2:2017; IEC 61800-5-2:2016-04
IEC 61850-3Name not checked yet
EN 61850-3:2014-07; IEC 61850-3:2013-12; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
CISPR
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
DIN EN 61000-6-7:2015-12; EN 61000-6-7:2015; IEC 61000-6-7:2014-10; DIN EN 55011:2022-05; EN 55011:2016 + A1:2017 + A11:2020 + A2:2021
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
DIN EN 55016-2-1:2019-11; EN 55016-2-1:2014 + A1:2017; CISPR 16-2-1:2014-02 /COR1:2020-08; CISPR 16-2-1:2014-02 /AMD1:2017-06; CISPR 16-2-1:2014-02; DIN EN 61000-4-2:2009-12; EN 61000-4-2:2009; IEC 61000-4-2:2008
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
CISPR 11:2015-06 + /AMD2:2019-01; CISPR 11:2015-06 + /AMD1:2016-06; CISPR 11:2015-06; DIN EN 55022:2011-12 Berichtigung 1:2016-08 (EN 55022:2010/AC:2011); DIN EN 55022:2011-12 (EN 55022:2010); CISPR 22:2008-09
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
DIN EN 55032:2022-08; EN 55032:2015 + AC:2016 + A11:2020 + A1 :2020; CISPR 32:2015-03 /AMD1:2019-10; CISPR 32:2015-03 /COR1:2016; CISPR 32:2015-03
EN 50121 series
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
IACS E10 Rev.8 2021/Corr.1 2022; EN 50155:2017-10; EN 50155:2017; EN 50121-3-2:2016-12/A1:2019-04; EN 50121-3-2/A1:2019
EN 50121-3-2:2016-12; EN 50121-3-2:2016; EN 50121-4 :2016-12 /A1:2019-04; EN 50121-4/A1:2019; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50121-3-2:2016-12; EN 50121-3-2:2016; EN 50121-4 :2016-12 /A1:2019-04; EN 50121-4/A1:2019; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
EN 50121-4:2016-12; EN 50121-4:2016; EN 50121-5:2017-03; A1:2019-04; EN 50121-4/A1:2019
EN 50121-5:2017-03; EN 50121-4:2017; IEC 62236-3-2:2018-02; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
EN 50121-5Name not checked yet
EN 50121-4:2016-12; EN 50121-4:2016; EN 50121-5:2017-03; A1:2019-04; EN 50121-4/A1:2019
EN 50121-5:2017-03; EN 50121-4:2017; IEC 62236-3-2:2018-02; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
IEC 62236 series
IEC 62236-3-2Name not checked yet
EN 50121-5:2017-03; EN 50121-4:2017; IEC 62236-3-2:2018-02; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
IEC 62236-4Name not checked yet
IEC 62236-4:2018-02; IEC 62236-5:2018-02; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
IEC 62236-5Name not checked yet
IEC 62236-4:2018-02; IEC 62236-5:2018-02; 61000-4-2; 61000-4-6; 61000-4-4; 61000-4-5
Other standards
EN 50155Railway applications - Rolling stock - Electronic equipment
IACS E10 Rev.8 2021/Corr.1 2022; EN 50155:2017-10; EN 50155:2017; EN 50121-3-2:2016-12/A1:2019-04; EN 50121-3-2/A1:2019
Scope as published by DAKKS
24 lines
ISO/IEC 17025
ActiveD-PL-20648-01-01
ISO/IEC 17025
ActiveD-PL-20648-01-00
Location
Labs with overlapping accredited scope in Germany
- DEKRA Testing and CertificationStuttgart · ~126 kmDAKKSShares 1 accredited test methodEN 61000-6-3
- Spezial-EMVSt. Ingbert · ~183 kmDAKKSShares 1 accredited test methodEN 61000-4-2:2009
- TQ-Systems GmbH TQ Product Compliance Center AugsburgAugsburg · ~189 kmDAKKSShares 1 accredited test methodEN 61000-6-3
- PHOENIX TESTLABBlomberg · ~237 kmDAKKSShares 1 accredited test methodEN 61000-6-3
- RS Schwarze Industrieelektronik GmbH EMV-LaboratoriumSchloss Holte-Stukenbrock · ~239 kmDAKKSShares 1 accredited test methodEN 61000-6-3
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.