SICAME
1, avenue Basile Lachaud, 19230, POMPADOUR, France
- Scope lines
- 17
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
COFRAC certificate 1-1068 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | APPAREILLAGE INDUSTRIEL BASSE TENSION; ACCESSOIRES ET CABLES UTILISES POUR LES RESEAUX DE L'ENERGIE | - |
| 2 | - | Accessories and cables used for energy transport networks; Low voltage industrial apparatusShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 3/19
Section Laboratoires
ANNEXE TECHNIQUE
à l’attestation N° 1-1068 rév. 15
L’accréditation concerne les prestations réalisées par :
SICAME
1, avenue Basile Lachaud
19230 POMPADOUR
Dans son unité :
- LABORATOIRE D'ESSAIS LABEP
Elle est accordée selon le périmètre suivant :
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie
Electricity / Accessories and cables used for energy transport networks
/ Essais de sécurité et de performance (44)
/ Safety and performance tests (44)
Electricité / Appareillage industriel basse tension
Electricity / Low voltage industrial apparatus
/ Essais de sécurité et de performance (13)
/ Safety and performance tests (13)
Pour tous les essais concernant cette accréditation :
(*) Le laboratoire est reconnu compétent, dans le domaine couvert par la portée générale, pour adopter toute
méthode reconnue et pour développer ou mettre en œuvre toute autre méthode dont il aura assuré la
validation. (FLEX3).
La liste exhaustive des méthodes proposées sous accréditation est mise à disposition par le laboratoire .
For all tests for this certification:
(*)The laboratory is recognized as competent in the field covered by the general scope to adopt a ny recognized
method and to develop or implement any other method which it has validated (FLEX3).
The exhaustive list of methods proposed under accreditation is made available by the laboratory. | - |
| 3 | - | Appareillage industriel BT; Accessoires aériens BT et HTa; Accessoires souterrains BT et HTa; Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessories; Accessoires souterrains BT; Low voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 4/19
Portée générale / General scope :
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
1
Essai de vieillissement
électrique
Electrical ageing test
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Résistance électrique, température,
distance, temps, nombre de cycles, couple
de serrage (le cas échéant)
Electrical resistance, temperature, distance,
time, number of cycles, tightening torque (if
applicable)
Les raccords ou les accessoires avec les conducteurs
associés sont soumis à des cycles de chauffage par
passage de courant intercalés avec des périodes de
refroidissement et sont soumis éventuellement à des
surintensités de courte durée suivant leur utilisation (voir
essai de surintensité).
Fittings or accessories and associated cables are
subjected to heating cycles by passing current
interspersed with periods of cooling and are subject
possibly overcurrent short of their use (see test
overcurrent).
2
Essai de tenue
diélectrique
Dielectric withstand test
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low voltage underground
accessories
Tension, temps, hauteur d’immersion dans
l’eau (le cas échéant), courant de fuite (le
cas échéant),
Absence de claquage
Voltage, time, height immersion in water (if
appropriate), leakage current (if
appropriate)
No breakdown
Une tension alternative à fréquence industrielle est
appliquée entre les parties actives du matériel et les
masses (eau, feuille d’aluminium, billes de plomb,…)
An AC voltage at power frequency is applied between
live parts of equipment and the masses (water, aluminum
foil, lead balls, ...) | - |
| 4 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessories; Devices and associated cablesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 5/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
3
Essai mécanique de
traction
Mechanical tensile test
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Absence de rupture, mesure de glissement
ou déformation sous une force de traction
donnée, temps
Failure, slip or deformation under traction,
time
Effort de traction exercé sur le câble ou le produit ;
vérification de la tenue mécanique
Tensile force exerted on the cable or the product;
checking the mechanical strength
4
Essai d’endurance sous
contraintes mécaniques
et thermiques
Endurance test under
mechanical and thermal
stresses
Accessoires aériens BT et HTa
Low and medium voltage
overhead accessories
Température, temps, nombre de cycles,
Force, mesure de glissement
Temperature, time, number of cycles,
Force, slip measurement
Les matériels et les conducteurs associés sont soumis à
des périodes de chauffe par passage de courant
intercalés avec des périodes de refroidissement.
Simultanément, ils sont soumis à une contrainte
mécanique, cyclique ou non
Devices and associated cables are subjected to periods
of heating by passing current interspersed with periods of
cooling.
Simultaneously, they are subjected to mechanical cyclic
stress or not | - |
| 5 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 6/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
5
Essai de vieillissement
climatique
Testing of climate aging
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, humidité, éclairement, temps,
nombre de cycles
Mesures diélectriques (le cas échéant),
d'étanchéité (le cas échéant), mécanique
de traction ou mécanique de serrage (le cas
échéant) à l'issue de l'exposition, absence
de détérioration du produit (le cas échéant),
durabilité des marquages (le cas échéant)
Temperature, humidity, illumination, time,
number of cycles
Dielectric measurements (if appropriate),
sealing (if appropriate), traction (if
appropriate), tightening (if appropriate), no
deterioration of the product (if appropriate),
durability of markings (if appropriate)
Vieillissement accéléré par application de cycles
climatiques combinés incluant tout ou partie de : UV,
choc thermique ou variation de température, pluie,
humidité, suivi d’essai ou de mesure de contrôle du
produit
UV, heat shock or change in temperature, rain, humidity,
test monitoring or control measure product: accelerated
by application of combined climatic cycles including all or
part of aging
6
Essai de tenue à la
corrosion au brouillard
salin
Test corrosion resistance
to salt spray
Appareillage industriel BT
Accessoires aériens BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Température, temps, concentration sel
Absence visuelle de rouille (le cas échéant),
couple de desserrage (le cas échéant),
force (le cas échéant), absence de
détérioration du produit (le cas échéant),
durabilité des marquages (le cas échéant)
Temperature, time, salt concentration
Visual absence of rust (if appropriate),
loosening torque (if appropriate), force (if
appropriate), no deterioration of the product
(if appropriate), durability of markings (if
appropriate)
Les matériels sont soumis à une exposition au brouillard
salin
Materials are subjected to a salt spray | - |
| 6 | - | Accessoires aériens BT et HTa; Accessoires souterrains BT; Appareillage industriel BTShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 7/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
7
Essai de montage à
basse température
(éventuellement à
température ambiante)
Low temperature
mounting test (possibly at
room temperature)
Accessoires aériens BT et HTa
Accessoires souterrains BT
Low and medium voltage
overhead accessories
Low voltage underground
accessories
Température, couple de serrage au contact,
Mesure diélectriques ou mécanique (le cas
échéant)
Temperature, tightening torque on contact,
Dielectric or mechanical measurement (if
applicable)
Une mise en œuvre des accessoires est effectuée (à
basse température et ambiante)
Accessories are installed (at low temperature)
8
Essai d’étanchéité ou
d’immersion
Waterproof or immersion
test
Accessoires aériens BT et HTa
Accessoires souterrains BT
Low and medium voltage
overhead accessories
Low voltage underground
accessories
Hauteur d’immersion (pression), temps,
liquide
Infiltration visuelle d'eau
Immersion height (pressure), time, liquid,
Visual infiltration of water
Les raccords montés sur un conducteur isolé sont
immergés dans l’eau
The connectors mounted on an insulated conductor are
immersed in water
13
Examen
Examination
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Absence de présence d’eau, absence de
détérioration du produit
Absence of water, no deterioration of the
product
Examen visuel
Visual examination
15
Essai de traction choc à
basse température
Tensile test low
temperature impact
Accessoires aériens BT et HTa
Low and medium voltage
overhead accessories
Température, force, temps, non
détérioration du produit
Temperature, force, time, no deterioration
of the product
Essai de traction sur un produit placé dans une enceinte
à basse température
Tensile test on a product placed in a chamber at low
temperature | - |
| 7 | - | Low voltage overhead accessories; Low and medium voltage overhead accessories; Medium voltage overhead or overhead-underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 8/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
16
Essai de connexion et de
déconnexion en charge
Connection and
disconnection test under
live load pick up
Accessoires aériens BT
Low voltage overhead
accessories
Tension, intensité de courant, Cos Phi,
temps, nombre de manœuvres,
Voltage, amperage, Cos Phi, time, number
of maneuvers
Effectuer une ou plusieurs connexions et déconnexions
en charge, puis des essais complémentaires de
vérification
Perform one or more connections and disconnection
under live load pick up, then additional verification tests
18
Essai de tenue à la
corrosion au dioxyde de
soufre
Test corrosion resistance
to sulfur dioxide
Accessoires aériens BT et HTa
Low and medium voltage
overhead accessories
Température, humidité, temps,
concentration dioxyde de soufre
Absence visuelle de rouille
Mesures de serrage mécanique ou de
tenue mécanique à la traction à l'issue de
l'exposition
Temperature, humidity, time, sulfur dioxide
concentration
Visual absence of rust
Tightening, traction
Les matériels sont soumis à une exposition en
atmosphère humide contenant du dioxyde de soufre
Materials are subjected to exposure in a humid
atmosphere containing sulfur dioxide
25
Essai en atmosphère
sous brouillard salin
Test in salt fog
atmosphere
Accessoires aériens ou aéro-
souterrain HTa
Medium voltage overhead or
overhead-underground
accessories
Temps, tension, concentration sel, Absence
de détérioration du produit (le cas échéant),
absence de claquage
Time, voltage, salt concentration,
No deterioration of the product (if
appropriate), no breakdown
Les accessoires sont soumis à une exposition au
brouillard salin sous une tension alternative
Accessories are subject to salt spray exposure in an
alternating voltage | - |
| 8 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 9/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
28
Essai du marquage
permanent
Test for permanent
marking
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Durabilité des marquages, temps
Durability of markings, time
Vérification de la tenue des marquages après action de
frottement avec eau et/ou solvant
Verification of the resistance of the markings after
rubbing action with water and / or solvent
29
Essai de surintensité ou
de courant de court-
circuit
Over-current or short-
circuit current test
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Résistance électrique (le cas échéant),
température, intensité de courant, temps,
nombre de surintensités
Electrical resistance (if applicable),
temperature, amperage, time, number of
overcurrents
Les raccords ou les accessoires avec les conducteurs
associés sont soumis à des surintensités de courte
durée. Ces surintensités sont appliquées pendant un
essai de vieillissement électrique ou un essai
d’échauffement
Fittings or accessories and associated cables are
subjected to surges of short duration. These surges are
applied during testing of electrical heating or aging test | - |
| 9 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 10/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
30
Essai de chaleur humide
Damp heat test
Appareillage industriel BT
Accessoires aériens BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Température, humidité, temps, nombre de
cycle, mesures diélectriques (le cas
échéant), résistance électrique (le cas
échéant)
Absence de détérioration du produit
Temperature, humidity, time, cycle number,
dielectric measurements (if appropriate),
electrical resistance (if appropriate),
No deterioration of the product
Les matériels sont soumis à des cycles de température
avec humidité
Materials are subjected to cycles of temperature with
humidity
31
Essai de tenue aux
ondes de choc en tension
à température ambiante
- essai à température
élevée
(le cas échéant)
Withstand test voltage
shock waves at room
temperature
- test at high temperature
(if appropriate)
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Tension, temps,
Température (le cas échéant), nombre
d’impulsion
Voltage, time,
Temperature (if appropriate), pulse number
Une tension de choc est appliquée entre les parties
actives du matériel et les masses ou la terre
An impulse voltage is applied between live parts of
equipment and land masses or ground
32
Essai de tenue à la
chaleur sèche
Test held in dry heat
Appareillage industriel BT
Accessoires aériens BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Température, temps,
Absence de détérioration du produit
Temperature, time,
No deterioration of the product
Les matériels sont soumis à un vieillissement thermique
The materials are subjected to a heat aging | - |
| 10 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 11/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
33
Essai de résistance
d’isolement
- essai d’immersion (le
cas échéant)
Insulation resistance test
- Immersion test (if
appropriate)
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low voltage underground
accessories
Résistance électrique, tension, temps,
hauteur d’immersion (pression)
Electrical resistance, voltage, time,
immersion height (pressure)
Une mesure de résistance d’isolement sous une tension
continue est effectuée sur le matériel entre parties
actives et masses (eau, feuille aluminium)
Measurement of insulation resistance in a DC voltage is
performed on the material between live parts and mass
(water, aluminum foil)
34
Essai mécanique de
serrage et/ou de
desserrage et/ou de
rupture
Mechanical tightening
and / or loosening test
and / or break
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, couple de serrage, de contact
et de rupture
Temperature, tightening, contact and
rupture torque
Mise en œuvre du produit dans des conditions extrêmes,
pour en tester la tenue mécanique
Implementation of the product in extreme conditions, to
test the mechanical strength
35
Essai de choc mécanique
à basse température
Mechanical shock test at
room low temperature
Accessoires aériens BT et HTa
Low and medium voltage
overhead accessories
Masse, distance, température
Mass, distance, temperature
Chute de poids ou marteau
Drop weight or hammer | - |
| 11 | - | Low and medium voltage overhead accessories; Low and medium voltage underground accessories; Low voltage industrial switchgearShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 12/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
36
Essai de choc mécanique
à température ambiante
Mechanical shock test at
room temperature
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Masse, distance, température
Mass, distance, temperature
Chute de poids ou marteau
Drop weight or hammer
37
Mesure de resistance
électrique
Electrical resistance
measurement
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Résistance, température (le cas échéant)
Resistance, temperature (if applicable)
La résistance électrique (de contact) est déterminée par
la mesure de la chute de tension aux bornes d’un raccord
ou d’un accessoire traversé par un courant continu
The electrical resistance (contact) is determined by
measuring the voltage drop across a connector or an
accessory through which a direct current passes
38
Essai de décharges
partielles
- essai à température
élevée
(le cas échéant)
Partial discharge test
- test at high temperature
(if appropriate)
Accessoires souterrains HTa
Medium voltage underground
accessories
Tension, temperature
Voltage, temperature
Mesure des décharges partielles d’une isolation
électrique portée à une tension alternative spécifiée
Partial discharge measurement of electrical insulation to
reach an AC voltage specified | - |
| 12 | - | Medium voltage underground accessories; Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 13/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
39
Essai de tenue sous
tension à sec avec
éventuellement des
paliers de tension
Dry voltage withstand
test with possible voltage
steps
Accessoires souterrains HTa
Medium voltage underground
accessories
Tension, temps,
Absence de claquage
Voltage, time,
No breakdown
Une tension est appliquée entre la phase et la terre
A voltage is applied between the phase and ground
41
Essai de déconnexion /
connexion
Test disconnection /
connection
Accessoires souterrains HTa
Medium voltage underground
accessories
Pas de dommage visuel du contact
No visual damage of the contact
5 opérations complètes
5 complete operations
42
Essai de vérification du
degré de protection IP2X
Verification test of the
degree of protection IP2X
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Inaccessibilité aux parties internes,
protection contre la pénétration d’objets et
d’eau
Inaccessibility to internal parts, protection
against penetration of objects and water
Vérification de l’inaccessibilité des parties actives ou des
parties à isolation principale
Checking the markings required after rubbing action with
water and / or solvent | - |
| 13 | - | Accessoires aériens BT et HTa; Accessoires souterrains BT et HTa; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 14/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
43
Essai de cycles
thermiques dans l’eau
Thermal cycle test in the
water
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, tension, temps, nombre de
cycles, pression d’eau ou hauteur
d’immersion dans l’eau, résistance
électrique (le cas échéant), distance (le cas
échéant), couple de serrage (le cas
échéant).
Temperature, voltage, time, number of
cycles, water pressure or depth of water
immersion, electrical resistance (if
applicable), distance (if applicable),
tightening torque (if applicable).
Les raccords ou les accessoires avec les conducteurs
associés sont soumis à des cycles de chauffage par
passage de courant intercalés avec des périodes de
refroidissement et sont soumis éventuellement à des
surintensités de courte durée suivant leur utilisation (voir
essai de surintensité). Les cycles sont réalisés dans l’air
ou dans l’eau ou enterré.
Fittings or accessories and associated cables are
subjected to heating cycles by passing current
interspersed with periods of cooling and are subject
possibly overcurrent short of their use (see test
overcurrent). The cycles are carried out in air or in water
or buried and / or alternating voltage
44
Essai de cycles
thermiques dans l’air
Thermal cycle test in air
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, tension, temps, nombre de
cycles, résistance électrique (le cas
échéant), distance (le cas échéant), couple
de serrage (le cas échéant).
Temperature, voltage, time, number of
cycles, electrical resistance (if applicable),
distance (if applicable), tightening torque (if
applicable).
Les raccords ou les accessoires avec les conducteurs
associés sont soumis à des cycles de chauffage par
passage de courant intercalés avec des périodes de
refroidissement et sont soumis éventuellement à des
surintensités de courte durée suivant leur utilisation (voir
essai de surintensité). Les cycles sont réalisés dans l’air
ou dans l’eau ou enterré.
Fittings or accessories and associated cables are
subjected to heating cycles by passing current
interspersed with periods of cooling and are subject
possibly overcurrent short of their use (see test
overcurrent). The cycles are carried out in air or in water
or buried and / or alternating voltage | - |
| 14 | - | Accessoires aériens BT et HTa; Accessoires souterrains BT et HTa; Low and medium voltage overhead accessories; Low and medium voltage underground accessories; Accessoires souterrains BT; Low voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 15/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
45
Essai de cycles
thermiques dans le sol
Thermal cycle test in the
ground
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, tension, temps, nombre de
cycles, profondeur sous gravas, résistance
électrique (le cas échéant), distance (le cas
échéant), couple de serrage (le cas
échéant).
Temperature, voltage, time, number of
cycles, depth under rubble, electrical
resistance (if applicable), distance (if
applicable), tightening torque (if applicable).
Les raccords ou les accessoires avec les conducteurs
associés sont soumis à des cycles de chauffage par
passage de courant intercalés avec des périodes de
refroidissement et sont soumis éventuellement à des
surintensités de courte durée suivant leur utilisation (voir
essai de surintensité). Les cycles sont réalisés dans l’air
ou dans l’eau ou enterré.
Fittings or accessories and associated cables are
subjected to heating cycles by passing current
interspersed with periods of cooling and are subject
possibly overcurrent short of their use (see test
overcurrent). The cycles are carried out in air or in water
or buried and / or alternating voltage
46
Essai de compatibilité de
la connectique avec la
matière de remplissage
Compatibility of the
connections with the
filling test
Accessoires souterrains BT
Low voltage underground
accessories
Non dégradation des contacts électriques,
résistance électrique
No degradation of electrical contacts,
electrical resistance
Vérification de la non dégradation des contacts
électriques par la matière de remplissage en mesurant la
résistance électrique des connecteurs avant mise en
place de la matière de remplissage, après la
polymérisation
Verification of no degradation of the electrical contacts by
the filler by measuring the electric resistance of the
connectors before introduction of the filling material after
polymerization | - |
| 15 | - | Low voltage industrial switchgear; Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 16/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
47
Essai de contrôle de la
continuité électrique
- conducteur principal
sans contrainte de
traction (le cas échéant)
Control of the electrical
continuity- main cable
without tensile stress (if
appropriate)
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Force, continuité électrique
Force, electrical continuity
Vérification de la perforation des conducteurs
Checking perforation cable
48
Essai de stabilité
thermique
Thermal stability test
Accessoires souterrains BT
Low voltage underground
accessories
Température, temps
Temperature, time
Vérification de la stabilité en température du produit
quand il est soumis à une chauffe
Checking the temperature stability of the product when it
is subjected to heating
49 Essai d’échauffement
Appareillage industriel BT
Accessoires aériens BT et
HTa
Accessoires souterrains BT et
HTa
Low voltage industrial
switchgear
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Température, courant, résistance électrique
(le cas échéant)
Temperature, current, electrical resistance
(if applicable)
Le matériel en essai est soumis à un échauffement par
passage d’un courant alternatif d’intensité déterminé. Il
est soumis éventuellement à des surintensités de courte
durée (voir essai de surintensité)
The equipment under test is subjected to heating by
passing an alternating current of determined intensity. It
may be subjected to short-term overcurrents (see
overcurrent test) | - |
| 16 | - | Accessoires aériens BT et HTa; Accessoires souterrains BT et HTa; Accessoires aériens ou aéro-souterrain HTa; Accessoires souterrains BT; Accessoires aériens BT et HTaShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 17/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
50
Essai d’aptitude au
sertissage
Aptitude test crimping
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low voltage underground
accessories
Vérification de la fermeture des matrices
sous effort avec cales
Closure of the matrices
Vérification de la qualité de sertissage des manchons à
un effort donné
Checking the quality crimping sleeves at a given stress
52
Essai en atmosphère
sous humidité
Humid atmosphere test
Accessoires aériens ou aéro-
souterrain HTa
Medium voltage overhead or
overhead-underground
accessories
Tension, humidité, temps,
Absence de détérioration du produit
Voltage, humidity, time,
No deterioration of the product
Les accessoires sont soumis à une exposition sous
atmosphère humide et sous une tension alternative
Accessories are subjected to exposure under a humid
atmosphere and under alternating voltage
58
Essai de comportement
en présence d'eau dans
l'âme des câbles
Behavior in the presence
of water in the core
cables test
Accessoires souterrains BT
Low voltage underground
accessories
Non dégradation de l'accessoire
No degradation of the accessory
Vérification de la non dégradation de l'accessoire et de
son isolement en présence d'eau dans l'âme des câbles
Verification of no degradation accessory and isolation in
the presence of water in the core cables
59
Essai de tenue à la
corrosion à la soude
Test of resistance to
corrosion in the sodium
Accessoires aériens BT et HTa
Low and medium voltage
overhead accessories
Concentration soude, hauteur d’immersion,
temps,
Aucune trace visuelle de corrosion
Sodium concentration, immersion height,
time,
No visual evidence of corrosion
Les raccords et les câbles associés sont immergés dans
une solution de soude
The connectors and associated cables are immersed in a
sodium hydroxide solution | - |
| 17 | - | Low and medium voltage overhead accessories; Low and medium voltage underground accessoriesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Accréditation n° 1-1068
LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 18/19
Electricité / Accessoires et câbles utilisés pour les réseaux de transport de l’énergie (44)
Electricity / Accessories and cables used for energy transport networks (44)
Electricité / Appareillage industriel basse tension (13)
Electricity / Low voltage industrial apparatus (13)
N° Nature de l'essai
Nature of test
Objet soumis à essai
Object under test
Caractéristique mesurée ou recherchée
Measured Characteristics
Principe de la méthode
Principle of the method
60
Vérification des
caractéristiques
dimensionnelles
Verification of
dimensional
characteristics
Accessoires aériens BT et HTa
Accessoires souterrains BT et
HTa
Low and medium voltage
overhead accessories
Low and medium voltage
underground accessories
Dimensions
Dimensions
Mesures de caractéristiques géométriques
Measures geometrical characteristics
# Accréditation rendue obligatoire dans le cadre réglementaire français précisé par le texte cité en référence dans le document Cofrac LAB INF 99 disponible sur www.cofrac.fr | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.