Registers refreshed 2026-11-20.See refresh dates
Germany

Panasonic Automotive Systems Europe

Robert-Bosch-Straße 27-29, 63225, Langen, Germany

DAKKS D-PL-20714-01-00DAKKS D-PL-20714-01-01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
17
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 17 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-34
ISO4
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-20714-01-00

View scope

Accredited scope, certificate D-PL-20714-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO/IEC 17011; DIN EN ISO 9001--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-20714-01-01

View scope

Accredited scope, certificate D-PL-20714-01-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2IEC -CISPR 25:2021 -12; IEC -CISPR 25:2016 -10; IEC -CISPR 25:2008 -03; ISO 11452 -2:2019 -01; ISO 11452 -2:2004 -11; ISO 11452 -4:2020 -04; ISO 11452 -4:2011 -12Vehicles, boats and internal combustion enginesSee scope document
3ISO 11452-4:2005; ISO 11452-8:2015; ISO 11452-9:2021; ISO 11452-9:2012; ISO 7637-2:2011; ISO 7637-3:2016; ISO 7637-3:2007Road vehicles-
4ISO 10605:2023; ISO 10605:2008; IEC 61000-4-4:2012; IEC 61000-4-5:2014+AMD1:2017; IEC 61000-4-11:2020; IEC 61000-4-34:2005+AMD1:2009; IEC 61000-4-13:2002+AMD1:2009+AMD2:2015; IEC 61000-3-2:2018+AMD1:2020+AMD2:2024--
5IEC 61000 -3-12:2011+AMD1:2021; IEC 61000 -3-3:2013+AMD1:2017+AMD2:2021; IEC 61000 -3-11:2017; MBN 10284 -2:2019 -10; MBN 10284 -2:2015 -07; GS 95002 -2:2021 -05; GS 95002 -2:2019 -10; TL 81000:2021 -09equipment connected to public low-voltage systems; equipment with rated current ≤16 A per phase and not subject to conditional connection; Equipment with rated current ≤ 75 A and subject to conditional connection; Component Tests (Passenger Car and Vans); Komponentenprüfungen (PKW und Transporter); Motor vehicles components; Electronic Components for Motor Vehicles-
6TL 81000:2018 -03; TL 81000:2016 -02; JLR -EMC -CS Ver. 1.0 Anh. 3 und 4; PSA B21 7110 ind.F; CS.00244: 03.07.2023; ISO 16750 -2:2023 -07; MBN 10567:2018 -03; GS 95023: 2009 -12; GS 95024 -2:2021 -03--
7VW 80000:2021 -07--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Robert-Bosch-Straße 27-29, Langen, 63225, DE

50.00242, 8.65563

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.