TUV Rheinland Italia
via Enrico Mattei, 3, Pogliano Milanese, 20005, Italy, Pogliano Milanese, Italy
- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 7467.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; R205 | - | to 25 mm |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate,
Ammeters, Generators, Probes3
(100 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.999) A
(3 to 10.999) A
(11 to 20.5) A
(20 to 500) A
(500 to 3000) A
45 Hz to 1 kHz
0.13 % + 0.10 µA
0.1 % + 0.30 µA
0.04 % + 3.0 µA
0.04 % + 28 µA
0.07 % + 0.22 mA
0.08 % + 0.2 mA
0.09 % + 2.8 mA
0.17 % + 5.4 mA
0.078 % + 1 mA
0.14 % + 14 mA
Fluke 8508A,
Fluke 5522A,
Fluke 52120A,
Fluke coil 3kA
AC Current – Generate,
Ammeters, Generators, Probes3
(100 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.999) A
(3 to 10.999) A
(11 to 20.5) A
(20 to 500) A
(500 to 3000) A
(1 to 3) kHz
0.3 % + 0.15 µA
0.2 % + 0.30 µA
0.08 % + 3 µA
0.10 % + 54 µA
0.6 % + 1 mA
3 % + 2.8 mA
3 % + 5.4 mA
0.17 % + 5.4 mA
0.6 % + 1 mA
0.62 % + 14 mA
Fluke 8508A,
Fluke 5522A,
Fluke 52120A,
Fluke coil 3kA
AC Current – Generate,
Ammeters, Generators, Probes3
(100 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.999) A
(3 to 10.999) A
(11 to 20.5) A
(3 to 5) kHz
0.3 % + 0.15 µA
0.2 % + 0.30 µA
0.08 % + 3 µA
0.10 % + 54 µA
0.6 % + 1 mA
0.6 % + 1 mA
3 % + 2.8 mA
3 % + 5.4 mA
Fluke 8508A,
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 3 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate,
Ammeters, Generators, Probes3
(100 to 329.99) µA
(0.33 to 3.2999) mA
(3.33 to 32.99) mA
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.999 A)
(5 to 10) kHz
0.8 % + 0.20 µA
0.5 % + 0.40 µA
0.2 % + 3.7 µA
0.2 % + 100 µA
2.5 % + 5 mA
2.5 % + 5 mA
Fluke 8508A,
Fluke 5522A
AC Current – Generate,
Ammeters, Generators, Probes3
(100 to 329.99) µA
(0.33 to 3.299) mA
(3.33 to 32.99) mA
(33 to 329.99) mA
(10 to 30) kHz
1.6 % + 0.40 µA
1 % + 0.7 µA
0.4 % + 4.9 µA
0.40 % + 200 µA
Fluke 8508A,
Fluke 5522A
AC Voltage – Generate,
Voltmeters, Generators3
(0.100 to 33) mV
(33 to 329) mV
(0.33 to 3.29) V
(3.3 to 32.99) V
(33 to 329.99) V
(330 to 1020) V
45 Hz to 20 kHz
45 Hz to 10 kHz
320 µV/V + 8.5 µV
300 µV/V + 24 µV
310 µV/V + 0.06 mV
250 µV/V + 0.64 mV
200 µV/V + 23 mV
310 µV/V + 25 mV
Fluke 8508A,
Fluke 5522A
AC Voltage – Generate,
Voltmeters, Generators3
(0.100 to 33) mV
(33 to 329) mV
(0.33 to 3.29) V
(3.3 to 32.99) V
(33 to 329.99) V
(20 to 50) kHz
1100 µV/V + 21 µV
430 µV/V + 200 µV
390 µV/V + 0.21 mV
430 µV/V + 2.1 mV
270 µV/V + 42m V
Fluke 8508A,
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 4 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current– Generate,
Ammeters, Generators
(60 to 329) µA
(0.33 to 2.999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099) A
(1.1 to 2.999) A
(3 to 10.99) A
(11 to 20.50) A
(20 to 200) A
(200 to 1000) A
150 µA/A + 20 nA
100 µA/A + 64 nA
100 µA/A + 840 nA
130 µA/A + 16 µA
220 µA/A + 43 µA
430 µA/A + 400 µA
540 µA/A + 640 µA
1000 µA/A + 850 µA
61 µA/A + 0.42 mA
0.35 mA/A + 5.3 mA
Fluke 8508A,
Fluke 5522A,
Fluke 52120A,
Fluke coil 3kA
DC Voltage – Generate,
Voltmeters, Generators
(0.1 to 3.2999) mV
(0.33 to 3.2999) V
(3.3 to 32.999) V
(33 to 329.99) V
(330 to 1020) V
20 µV/V + 1.1 µV
11 µV/V + 4.9 µV
12 µV/V + 49 µV
18 µV/V + 0.56 mV
18 µV/V + 2.5 mV
Fluke 8508A,
Fluke 5522A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate,
Voltmeters, Generators3
(0.100 to 33) mV
(33 to 329) mV
(0.33 to 3.29) V
(3.3 to 32.99) V
(33 to 329.99) V
(50 to 100) kHz
3500 µV/V + 23 µV
840 µV/V + 200 µV
740 µV/V + 0.24 mV
930 µV/V + 2.7 mV
2000 µV/V + 160 mV
Fluke 8508A,
Fluke 5522A
AC Voltage – Generate,
Voltmeters, Generators3
(0.33 to 3.299 99) V
(0.33 to 3.299 99) V
(100 to 500) kHz
500 kHz to 1 MHz
0.3 % + 2 mV
Fluke 8508A,
Fluke 5522A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 5 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC – AC High Voltage
/ HV Generators, HV
Meters, Pulse Generators
(DC & AC to 10kHz)
(1 to 7) kV peak
(1 to 5) kV rms
(1 to 1.6) kV
(1.6 to 4) kV
(4 to 7) kV
0.77 %
1.1 %
1.3 %
Fluke 8508A,
Fluke 5522A,
Tektronix DPO
7254, Pico
Technology TA044
DC Resistance – Generate,
Meters, Resistances
10 mΩ to 11 Ω
(11 to 32.999) Ω
(33 to 329.99) Ω
(0.33 to 3.299) kΩ
(3.30 to 32.999) kΩ
(33 to 329.99) kΩ
(0.33 to 3.29) MΩ
(3.30 to 32.299) MΩ
(33 to 32) MΩ
(330 to 1100) MΩ
40 µΩ/Ω + 23 µΩ
30 µΩ/Ω + 24 µΩ
28 µΩ/Ω + 240 µΩ
28 µΩ/Ω + 2.4 mΩ
28 µΩ/Ω + 24 mΩ
29 µΩ/Ω + 180 mΩ
63 µΩ/Ω + 17 Ω
350 µΩ/Ω + 1700 Ω
3000 µΩ/Ω + 170 000 Ω
1.5 % + 560 000 Ω
Fluke 8508A
Fluke 5522A
DC Power – Power Meters
& Generators
Voltage:
(0.33 to 3.2999) V
Current:
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
(0.011 to 1.1) W
(0.036 to 3.6) W
(0.099 to 9.9) W
(0.363 to 36.3) W
(0.677 to 67.7) W
0.013 % + 0.093 mW
0.022 % + 0.14 mW
0.043 % + 1.3 mW
0.054 % + 2.1 mW
0.10 % + 2.8 mW
Fluke 5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 6 of 14
Parameter/Equipment
Range
CMC2,5 (±)
Comments
DC Power – Power Meters
& Generators
Voltage:
(3.3 to 32.999) V
Current:
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
(0.109 to 10.9) W
(0.363 to 36.3) W
(0.99 to 99) W
(3.63 to 363) W
(6.765 to 676.5) W
0.013 % + 0.93 mW
0.022 % + 1.4 mW
0.043 % + 13 mW
0.054 % + 21 mW
0.10 % + 28 mW
Fluke 5522A
DC Power – Power Meters
& Generators
Voltage:
(33 to 329.999) V
Current:
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
1.089 W to 0.11 kW
3.63 W to 0.36 kW
9.9 W to 0.99 kW
36.3 W to 3.63 kW
67.65 W to 6.77 kW
0.013 % + 9.3 mW
0.022 % + 14 mW
0.043 % + 130 mW
0.054 % + 210 mW
0.100 % + 280 mW
Fluke 5522A
DC Power – Power Meters
& Generators
Voltage:
(33 to 329.999) V
Current:
(20 to 200) A
(200 to 1000) A
(0.66 to 66) kW
(3.3 to 330) kW
0.006 % + 0.18 W
0.035 % + 1.8 W
Fluke 5522A,
Fluke 52120A
Fluke coil 3 kA | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 7 of 14
Parameter/Equipment
Range
CMC2,5 (±)
Comments
DC Power – Power Meters
& Generators
Voltage:
(330 to 1020) V
Current:
(33 to 329.99) mA
(0.33 to 1.0999) A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
3.366 W to 0.34 kW
11.22 W to 1.12 kW
30.6 W to 3.06 kW
112.2 W to 11.22 kW
209.1 W to 20.91 kW
0.013 % + 29 mW
0.022 % + 44 mW
0.043 % + 410 mW
0.054 % + 650 mW
0.100 % + 870 mW
Fluke 5522A
Parameter/Range
Frequency
CMC2,5 (±)
Comments
AC Impedance
10 mΩ to 10 kΩ
10 Hz to 1 kHz
0.10 %
Fluke 8508A,
Fluke 5522A,
Fluke 52120A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(33 to 329.99) mA
(PF = 1)
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.049 % + 12 mW
0.10 % + 19 mW
0.20 % + 35 mW
0.40 % + 68 mW
Fluke 8508A
Fluke 5522A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(0.33 to 1,0999) A
(PF = 1)
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.07 % + 0.077 W
0.60 % + 0.330 W
2.5 % + 1.7 W
Fluke 8508A
Fluke 5522A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 8 of 14
Parameter/Range
Frequency
CMC2,5 (±)
Comments
AC Power – Power Meters
& Generators
(33 to 329.99) V
(1.1 to 2.9999) A
(PF = 1)
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.08 % + 0.100 W
0.60 % + 0.340 W
2.5 % + 1.650 W
Fluke 8508A
Fluke 5522A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(3 to 10.999) A
(PF = 1)
(45 to 100) Hz
(100 to 1000) kHz
(1 to 5) kHz
0.09 % + 0.97 W
0.12 % + 0.97 W
3.0 % + 0.97 W
Fluke 8508A
Fluke 5522A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(11 to 20.5) A
(PF = 1)
(45 to 100) Hz
(100 to 1000) kHz
(1 to 5) kHz
0.14 % + 1.8 W
0.17 % + 1.8 W
3.0 % + 1.8 W
Fluke 8508A
Fluke 5522A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(20 to 100) A
(PF = 1)
(45 to 1000) Hz
(1000 to 3000) Hz
0.14 % + 5.1 W
0.52 % + 5.1 W
Fluke 8508A
Fluke 5522A
Fluke 52120A
AC Power – Power Meters
& Generators
(33 to 329.99) V
(100 to 600) A
(PF = 1)
(45 to 300) Hz
(300 to 1000) Hz
0.22 % + 15 W
0.59 % + 15 W
Fluke 8508A
Fluke 5522A
Fluke 52120A
Fluke 3kA | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 9 of 14
Parameter/Range
Frequency
CMC2,5 (±)
Comments
AC Power – Power Meters
& Generators
(33 to 329.99) V
(600 to 3000) A
(PF = 1)
(45 to 300) Hz
(300 to 1000) Hz
0.43 % + 70 W
0.78 % + 70 W
Fluke 8508A
Fluke 5522A
Fluke 52120A
Fluke 3kA
Parameter/Frequency
Range
CMC2,5 (±)
Comments
Flicker Analyzer
(45 to 65) Hz
(50 to 300) V
1.2 %
Fluke 5522A
Temperature simulation
for Type J, K, T
Thermocouples
(-100 to 1200) °C
0.28 °C
Fluke 5522A
III. Electrical – RF/Microwave
Parameter/Equipment
Range
CMC2,5 (±)
Comments
Pulse Level / FTB
Generators
50 Ω Attenuator
1000 Ω Attenuator
(0.5 to 6) kV
5.3 %
8 %
Tektronix DPO
7254, Emtest KW
50 & KW1000
Rise Time / FTB
Generators
(3.5 to 6.5) ns
6.2 %
Tektronix DPO
7254, Emtest KW
50 & KW1000
Duration / FTB Generators
(35 to 65) ns
8.6 %
Tektronix DPO
7254, Emtest KW
50 & KW1000 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 10 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pulse Level / Surge
Generators
(0.5 to 6) kV
5.2 %
Tektronix DPO 7254,
Pico Technology
TA044, Kirkby
85054B, Pearson 411,
Attenuator 20 dB
Rise Time / Surge
Generators
(0.84 to 1.56) µs
13 %
Tektronix DPO 7254,
Pico Technology
TA044, Kirkby
85054B, Pearson 411,
Attenuator 20 dB
Duration/ Surge
Generators
(40 to 60) µs
1.5 %
Tektronix DPO 7254,
Pico Technology
TA044, Kirkby
85054B, Pearson 411,
Attenuator 20 dB
Reflection Coefficient
/ Attenuators, LISN, CDN,
RF Cables, RF Loads, RF
Amplifiers
5 kHz to 100 MHz
100 MHz to 2 GHz
(2 to 3) GHz
50 MHz to 2 GHz
(2 to 8) GHz
(8 to 20.5) GHz
0.012 dB
0.020 dB
0.033 dB
0.053 dB
0.13 dB
0.29 dB
Rohde&Schwarz
ZCAN,
Hewlett-Packard
85052A
Transmission /Attenuators,
LISN, CDN, RF Cables,
RF Amplifiers
10 kHz to 300 MHz
50 MHz to 2 GHz
0.20 dB
0.15 dB
Rohde&Schwarz
ZCAN, Hewlett-
Packard 85052A
Voltage Harmonics
Analyzer, Voltage THD
Analyzer
3
(Max 16 harmonics
selected from 2 to 50)
120/230 V. 50/60 Hz
fundamental
0.55 %
Fluke 8508A,
Fluke 5522A,
Fluke 52120A | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 11 of 14
Parameter/Equipment
Range
CMC2,5 (±)
Comments
Current Harmonics
Analyzer,
Current THD Analyzer3
(Max 16 harmonics
selected from 2 to 50)
10 A at 50 Hz & 17 A
at 60 Hz
0.35 %
Fluke 8508A,
Fluke 5522A,
Fluke 52120A
IV. Fluid Quantities
Parameter/Equipment
Range
CMC2,5 (±)
Comments
Liquid Flow / Flowmeters,
IP
Up to 120 l/min
0.30 %
Sinergica Soluzione
WSF1MK1,WM1VK5,
WM1VK10 &
WM1VK20, Sartorius
HC1toLC34, RS
Components Quantum
V. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Mass – Weight Scales &
Masses
(1 to 9.9999) g
(10 to 99.999) g
(100 to 999.99) g
(1 to 4.9999) kg
(5 to 9.9999) kg
(10 to 49.999) kg
(50 to 99.999) kg
(100 to 299.99) kg
6.0 mg
8.0 mg
55 mg
0.26 g
0.52 g
2.6 g
5.2 g
16 g
Sinergica Soluzione
WSF1MK1,
WM1VK5,
WM1VK10 &
WM1VK20 | to 50 |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 12 of 14
VI. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Humidity –
Hygrometers
(0 to 60) °C
(20 to 95) %RH
1.5 % RH
Agilent 34970A +
PT100, Delta Ohm
HD 2301.OR
Humidity –
Climatic Chambers
Up to 75% RH
(> 75 to 95) % RH
2.1 % RH
2.8 % RH
Delta Ohm
HD 2301.OR
Temperature/ Digital
Thermometers &
Temperature probes
(-40 to 140) °C
(140 to 200) °C
0.11 °C
0.38 °C
Fluke 8508A,
Tersid PT100,
calibration furnace
Temperature –
Temperature Chambers
(-60 to 180) °C
0.22 °C
Agilent 34970A &
34901A, plus PRT
thermometer
VII. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Frequency Meters
10 Hz to 1 MHz
29 x 10-7 Hz
Fluke 5522A, Rohde
& Schwarz ESCS30
Frequency Generators3
10 kHz to 2.7 GHz
9.2 x 10-5 Hz
Fluke 5522A, Rohde
& Schwarz ESCS30
Time / Stopwatches
(0 to 3600) sec
20 x 10-6 Hz
on 1 hour integration
RS Components
Quantum, Tektronix
DPO 7254, Pico
Technology TA044 | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 13 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Normalised Site
Attenuation of
Semianechoic Chamber
(SAC)
3
30 MHz to 1 GHz
2.3 dB
Antenna BiLog
Schwarzbeck VULB
9168, Antenna
LogPeriodic Rohde &
Schwarz HL223,
Antenna Biconica
ETS Lindgren 3104C,
Antenna Biconica
Rohde & Schwarz
HK116 E, Rohde &
Schwarz SMB100B,
HP 83640A, Rohde &
Schwarz ESW 44
sVSWR of SAC3
(1 to 18) GHz
3.8 dB
Seibersdorf POD16,
Seibersdorf POD 618,
Rohde & Schwarz
SMB100B, HP
83640A, Rohde &
Schwarz ESW 44
Field Uniformity3
26 MHz to 6 GHz
4.9 dB
Lumiloop Ls Probe
1.2, Rohde &
Schwarz
SMB100A/B, RF
Amplifier, ETS
Lindgren 3119,
Schwarzbeck STLP
9128, Schwarzbeck
BBFA 9146 + coil
____________________________________________
1 This laboratory offers commercial dimensional testing, calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration. | 30 to 1 MHz to GHz |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7467.01) 02/19/2026 Page 14 of 14
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 In the statement of CMC, % is defined as the percentage of reading unless otherwise indicated. | ||
| 15 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
via Enrico Mattei, 3, Pogliano Milanese, 20005, Italy, Pogliano Milanese, IT
45.53730, 8.99163
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.