Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Cefas, Food Safety

The CEFAS Weymouth Laboratory, The Nothe, Barrack Road, DT4 8UB, Weymouth, United Kingdom

Visit website
UKAS 2293ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
3
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 3 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 15216-1Microbiology of the food chain - Horizontal method for determination of hepatitis A virus and norovirus using real-time RT-PCR - Part 1: Method for quantification
ISO 16649-3Microbiology of the food chain - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 3: Detection and most probable number technique using 5-bromo-4-chloro-3-indolyl-ß-D-glucuronide

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

6 lines
UKAS

ISO/IEC 17025

Active

2293

View scope

Accredited scope, certificate 2293

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; SOP 2308water; Food; FOOD-
2ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO15216-1:2017; IEC 17025; SOP 1330; SOP 2076Food products-
3ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; SOP 3152; SOP EZ-1; SOP 2108Food products-
4ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 16649-3:2015; ISO6579- 1:2017; IEC 17025; SOP willFood products-
5ISO/IEC 17025:2017; Commission Decision (EU) 2015/1554; WOAH Manual of Diagnostic Tests for Aquatic AnimalsFood products-
6ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; SOP 1681; SOP 1795; SOP 1797Food products-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

The CEFAS Weymouth Laboratory, The Nothe, Barrack Road, Weymouth, DT4 8UB, GB

50.60963, -2.45434

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.