Aldinger Company

Dallas, TX, United States

Visit website
A2LA 1509.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
38
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 38 scope lines.

A2LA certificate 1509.01 · 38 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 1440-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 2 of 37 II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Calipers3 Up to 24 in (24 to 48) in Up to 48 in (48 to 96) in 550 µin 1100 µin 77 µin 1500 µin Gage blocks (field) Gage blocks (lab) Dial & Test Indicators3 Up to 1 in Up to 3 in Up to 3 in 20 µin 59 µin 90 µin Gage blocks (lab) Gage blocks, ULM, SuperMicrometer10 (lab) Gage blocks (field) Gage Blocks Up to 1 in (2 to 4) in (4 to 20) in (3.3 + 1.5L) µin (7.7 + 1.5L) µin (7 + 2L) µin Master gage block set, Federal 130B-24 comparator Maser gage block set, ULM Angle Blocks Up to 90° 0.005° Sine bar & gage blocks Squares Up to 18 in 99 µin Master square, amplified gage head Height Gages3 Up to 48 in 280 µin 89 µin Gage blocks (field) Gage blocks (lab) Length Standards Up to 18 in Up to 48 in (37 + 1.5L) µin (65 + 1.5L) µin ULM/SuperMicrometer9, gage blocks Levels3 Up to 12 in (40 + 14L) µin Surface plate, granite square Micrometers3 Up to 4 in (4 to 24) in (24 to 48) in Up to 4 in (4 to 24) in (24 to 96) in 92 µin 550 µin 1100 µin 15 µin 60 µin 1500 µin Gage blocks (field) Gage blocks (lab)
to 96 in
3ANSI B1-See scope document
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 4 of 37 Parameter/Equipment Range CMC2, 4 (±) Comments Surface Plates – Flatness & Repeatability3 Indicator Stands Up to 107 in DL (-0.002 to 0.002) in (-0.002 to 0.002) in (-0.01 to 0.01) in (48 + 0.41DL) µin 31 µin 45 µin 580 µin Leveling system (DL is diagonal of the plate) Repeat reading gage Repeat reading gage, triangular gage block base Indicator, triangular gage block base Optical Comparators3 X-Axis Y-Axis Angle Up to 12 in Up to 12 in Up to 90° (250 + 91L) µin (250 + 91L) µin 0.029° Glass scale Angle blocks Rulers3 Up to 72 in 0.013 in Standard ruler Radius Gages3 Up to 0.75 in 1300 µin Optical comparator & overlay Angle Gages3 Up to 180° 0.044° Optical comparator & vernier Torque Arms Up to 24 in Up to 48 in 0.0047 in 0.003 in Height gage, test indicator Gage blocks Coating/Electromagnetic Thickness3 Up to 120 mils 0.25 mils Shims Tape Measures3 Up to 40 in Up to 100 ft 0.013 in 0.062 in Standard ruler Standard tape PI Tapes Up to 72 in 910 µin Gage blocks
to 107 in
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 5 of 37 III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 6, 12 (±) Comments AC Current – Measure3 Up to 1 A (1 to 3) A 60 Hz to 1 kHz 0.16 % + 0.4 mA 0.14 % + 1.8 mA HP 34401A AC Current – Generate3 (29 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 10) A (10 to 20) A (16 to 150) A (150 to 1000) A 45 Hz to 1 kHz (45 to 440) Hz 0.13 % + 0.1 µA 0.10 % + 0.15 µA 0.07 % + 2 µA 0.083 % + 20 µA 0.10 % + 100 µA 0.21 % + 2 mA 0.21 % + 5 mA 1 % + 0.25 A 1 % + 0.9 A Fluke 5522A Using 50 turn coil AC Voltage – Generate3 (1 to 330) mV (0.330 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 1 kHz (1 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.018 % + 8 µV 0.018 % + 60 µV 0.017 % + 0.6 mV 0.023 % + 2 mV 0.023 % + 6 mV 0.046 % + 10 mV 0.040 % + 10 mV Fluke 5522A AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V Up to 10 kV Up to 50 kV 60 Hz to 3 kHz 0.063 % + 40 µV 0.063 % + 300 µV 0.062 % + 3 mV 0.064 % + 30 mV 0.075 % + 230 mV 0.12 % + 100 mV 0.1 % + 400 mV HP 34401A Vitrek 4700 w/ HVL-70
to 1020 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 6 of 37 Parameter/Equipment Range CMC2, 6, 12 (±) Comments Capacitance – Generate3 Low High (0.22 to 3.3) nF (3.3 to 33) nF (33 to 330) nF (330 to 3300) nF (3.3 to 33) µF (33 to 330) µF (330 to 3300) µF (3.3 to 110) mF 0.5 % + 10 pF 0.26 % + 100 pF 0.26 % + 300 pF 0.26 % + 3 nF 0.4 % + 30 nF 0.45 % + 300 nF 0.45 % + 3 µF 1.1 % + 10 µF Fluke 5522A DC Current – Generate3 (0 to 330) µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 3 A (1.1 to 11) A (11 to 20.5) A (10 to 150) A (150 to 1000) A 0.015 % + 20 nA 0.010 % + 50 nA 0.014 % + 250 nA 0.010 % + 2.5 µA 0.038 % + 40 µA 0.050 % + 500 µA 0.1 % + 750 µA 0.5 % + 0.14 A 0.5 % + 0.5 A Fluke 5522A Using 50 turn coil DC Current – Measure3 Up to 10 mA (10 to 100) mA 100 mA to 1 A (1 to 3) A 0.075 % + 6 µA 0.051 % + 5 µA 0.11 % + 100 µA 0.13 % + 600 µA HP 34401A DC Voltage – Generate3 (0 to 330) mV Up to 3.3 V Up to 33 V (30 to 330) V (100 to 1000) V 0.002 % + 1 µV 0.0012 % + 2 µV 0.0013 % + 20 µV 0.0018 % + 0.15 mV 0.0019 % + 1.5 mV Fluke 5522A DC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 10 kV Up to 70 kV 0.0054 % + 3.5 µV 0.0042 % + 7 µV 0.0037 % + 50 µV 0.0048 % + 600 µV 0.0049 % + 10 mV 0.041 % + 30 mV 0.049 % + 200 mV HP 34401A Vitrek 4700 w/ HVL-70
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 7 of 37 Parameter/Equipment Range CMC2, 12 (±) Comments Oscilloscopes3 Square Wave Amplitude: 50 Ω at 1 kHz 1 MΩ at 1 kHz DC Voltage Amplitude: 50 Ω Load 1 MΩ Load Level Sine Wave: Frequency Amplitude Flatness Time Markers: 50 Ω Load Rise Time – Generate 1 mV to 6.6 V pk-pk 1 mv to 130 V pk-pk Up to ± 6.6 V Up to ± 130 V Up to 1100 MHz 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 1 ns 1 kHz to 2 MHz (200 to 300) ps (2 to 10) MHz (200 to 300) ps 0.34 % + 40 µV 0.25 % + 40 µV 0.25 % + 40 µV 0.05 % + 40 µV 2.5 parts × 10 6 2.8 % + 300 µV 4.2 % + 300 µV 4.6 % + 300 µV 6.4 % + 300 µV 7.4 % + 300 µV 2.7 % + 100 µV 3.0 % + 100 µV 4.6 % + 100 µV 5.5 % + 100 µV 28 + 1000t µs/s 3.2 µs/s 120 ps 120 ps Fluke 5522A/ SC1100 t = time in seconds Electrical Calibration of Temperature Controllers 3 Thermocouple Types J, K, T & E PT385, 100 Ω (-200 to < 0) °C (0 to 1370) °C (-200 to 800) °C 1.2 °C 0.85 °C 0.66 °C Fluke 725
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 8 of 37 Parameter/Equipment Range CMC2, 6. 12 (±) Comments Resistance – Generate3 Up to 330 Ω (330 to 3300) Ω (3300 to 33 000) Ω (33 to 330) kΩ (330 to 3300) kΩ (3.3 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.065 % + 20 mΩ 0.029 % + 100 mΩ 0.029 % + 1.0 Ω 0.0037 % + 10 Ω 0.0063 % + 150 Ω 0.026 % + 2500 Ω 0.063 % + 3.0 kΩ 0.14 % + 100 kΩ 0.14 % + 500 kΩ Fluke 5522A Resistance – Measure3 Up to 100 Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 0.066 % + 4 mΩ 0.031 % + 10 mΩ 0.031 % + 100 mΩ 0.011 % + 1 Ω 0.012 % + 10 Ω 0.048 % + 100 Ω 0.8 % + 10 kΩ HP 34401A Electrical Simulation of RTD 3, PT385, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 630) °C (630 to 800) °C 0.058 °C 0.17 °C 0.12 °C 0.14 °C 0.28 °C Fluke 5522A
to 1100 MΩ
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 9 of 37 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Indicators3 Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0.0) °C (0.0 to 120) °C (120 to 400) °C 0.51 °C 0.16 °C 0.19 °C 0.20 °C 0.24 °C 0.28 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.20 °C 0.24 °C 0.40 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5522A Welding Devices3 (0 to 350) Amps DC (0 to 100) Volts DC (100 to 700) Feed Rate IPM 0.87 ADC 0.012 VDC 3.6 IPM Load bank, current shunt, DMM IV. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments POVA (Piston/Plunger Operated Volumetric Apparatus)3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (0.1 to 50) µL (50 to 100) µL (100 to 500) µL (500 to 1000) µL (1000 to 5000) µL (5000 to 10 000) µL (10 000 to 20 000) µL (20 000 to 50 000) µL 0.31 µL 0.31 µL 0.56 µL 0.72 µL 5.4 µL 18 µL 30 µL 72 µL Gravimetric method
10ison Balances3-See scope document
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 11 of 37 Parameter/Equipment Range7 CMC2 (±) Comments Mass, Fixed Points 1 mg 2 mg 5 mg 10 mg 20 mg 30 mg 50 mg 100 mg 200 mg 300 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 25 kg 0.8859 g ( 1/32 oz) 1.772 g (1/16 oz) 3.544 g (1/8 oz) 7.087 g (1/4 oz) 14.17 g (1/2 oz) 28.35 g (1 oz) 56.7 g (2 oz) 113.4 g (4 oz) 226.8 g (8 oz) 0.4536 g (0.001 lb) 0.9072 g (0.002 lb) 2.27 g (0.005 lb) 4.54 g (0.01 lb) 9.07 g (0.02 lb) 22.68 g (0.05 lb) 45.36 g (0.1 lb) 90.72 g (0.2 lb) 2.2 µg 2.1 µg 2.9 µg 1.4 µg 1.5 µg 2.2 µg 1.6 µg 1.7 µg 1.6 µg 1.6 µg 2.1 µg 11 µg 3.3 µg 5.7 µg 7.2 µg 13 µg 11 µg 39 µg 140 µg 320 µg 390 µg 1.7 mg 2.6 mg 93 mg 94 mg 140 mg 12 µg 94 µg 240 µg 170 µg 170 µg 370 µg 150 µg 740 µg 5.1 mg 130 µg 56 µg 26 µg 16 µg 56 µg 79 µg 37 µg 87 µg Modified double substitution Direct comparison
12ison Optical Tachometer3 Up to 200 FPM Up to 3000 FPM Up to 29 999 FPM 0-to 20000 lb
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 13 of 37 Parameter/Equipment Range CMC2, 8, 11 (±) Comments Torque Wrenches – Measure3 (1 to 10) lbf⋅in (10 to 50) lbf⋅in (30 to 400) lbf⋅in (80 to 1000) lbf⋅in (240 to 3000) lbf⋅in (1200 to 6000) lbf⋅in (2400 to 12 000) lbf⋅in 0.33 lbf⋅in 0.17 lbf⋅in 1.8 lbf⋅in 5.1 lbf⋅in 21 lbf⋅in 23 lbf⋅in 58 lbf⋅in CDI/Norbar torque calibrator Norbar torque calibrator Torque Measuring Equipment – Transducers Up to 200 lbf⋅in Up to 1200 lbf⋅in Up to 12 000 lbf⋅in 0.10 % 0.091 % 0.10 % Torque arm & weights Vacuum Measuring Equipment – Gauges3 Up to 13 psig 0.033 psig Druck DPI 610 Rotations Speed – Measurement3 Contact: Up to 200 RPM (200 to 3000) RPM (3000 to 20 000) RPM Optical: Up to 3000 RPM (3000 to 30 000) RPM 0.67 RPM 13 RPM 16 RPM 0.5 RPM 5.0 RPM Monarch PLT200 Indirect Verification of Rockwell Hardness Testers 3 HRB: Low Medium High HRC: Low Medium High 1.0 HRB 0.65 HRB 0.49 HRB 0.45 HRC 0.36 HRC 0.37 HRC Indirect verification Indirect Verification of Brinell Hardness Testers 3 HBW 10/500: Low HBW 10/3000: High 4.0 HBW 4.8 HBW Indirect verification
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 14 of 37 VI. Thermodynamics Parameter/Equipment Range CMC2, 11 (±) Comments Temperature – Measuring Equipment3 (-100 to 300) °C (-148 to 572) °F 0.09 °C 0.16 °F Hart 1502A/5614 PRT or Fluke 1523 Temperature – Measuring Equipment (-40 to 200) °C (-40 to 392) °F 0.061 °C 0.11 °F Hart 1502A/5614 PRT in wet bath Temperature –Measure3 (-100 to 600) °C (-148 to 1112) °F (> 600 to 1200) °C (> 1112 to 2192) °F 1.5 °C 2.7 °F 10 °C 18 °F Fluke 51 or 725 with thermocouple IR Thermometer3 (-20 to 150) °C (Amb + 10 to 400) °C 1.1 °C 2.1 °C Mikron M340 (lab only) Omega BB703 Emissivity ≈ 0.95 Wavelength (8 to 14) µm Humidity – Measure & Measuring Equipment3 (20 to 90) % RH 3.4 % RH SensoScientific B13-200 VII. Time & Frequency Parameter/Equipment Range CMC2, 6, 11 (±) Comments Frequency – Measuring Equipment3 Up to 1100 MHz 2.5 parts × 106 Fluke 5522A/SC1100 Frequency – Measure3 40 Hz to 300 kHz 0.014 % Indication HP 34401 Timers & Stopwatches3 Up to 1 hr (> 1 to 24) hr 0.14 s 0.59 s Reference stopwatch Stroboscopes3 Up to 3600 FPM Up to 30 000 FPM 0.11 FPM 0.72 FPM Universal counter
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 15 of 37 SATELLITE ALDINGER COMPANY 3130 Rogerdale Rd. STE 186 Houston, TX 77042 Dustin Detten Phone: 214 638 1808 CALIBRATION I. Chemical Parameter/Equipment Range CMC2 (±) Comments Conductivity Meters3 1 µS/cm 10 µS/cm 100 µS/cm 1000 µS/cm 10 000 µS/cm 100 000 µS/cm 0.55 µS/cm 0.41 µS/cm 2.8 µS/cm 20 µS/cm 190 µS/cm 1900 µS/cm Reference conductivity standards pH Meters3 Electrical Calibration Probe/Meter Standardization (0 to 14) pH 4 pH 7 pH 10 pH 0.015 pH 0.030 pH 0.030 pH 0.030 pH mV/pH calibrator Reference buffer standards II. Dimensional Parameter/Equipment Range CMC2 (±) Comments Calipers3 Up to 24 in (24 to 48) in Up to 48 in (48 to 96) in 550 µin 1100 µin 77 µin 1500 µin Gage blocks (field) Gage blocks (lab)
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 16 of 37 Parameter/Equipment Range CMC2, 4 (±) Comments Dial & Test Indicators3 Up to 1 in Up to 3 in Up to 3 in 20 µin 59 µin 90 µin Gage blocks (lab) Gage blocks, ULM, SuperMicrometer 10 (lab) Gage blocks (field) Height Gages3 Up to 48 in 280 µin 89 µin Gage blocks (field) Gage blocks (lab) Levels3 Up to 12 in (40 + 14L) µin Surface plate, granite square Micrometers3 Up to 4 in (4 to 24) in (24 to 48) in Up to 4 in (4 to 24) in (24 to 96) in 92 µin 550 µin 1100 µin 15 µin 60 µin 1500 µin Gage blocks (field) Gage blocks (lab) Protractors3 Up to 90° 0.049° Surface plate, angle blocks, sine bar w/ gage blocks Surface Plates – Flatness & Repeatability3 Indicator Stands Up to 107 in DL (-0.002 to 0.002) in (-0.002 to 0.002) in (-0.01 to 0.01) in (48 + 0.41DL) µin 31 µin 45 µin 580 µin Leveling system (DL is diagonal of the plate) Repeat reading gage Repeat reading gage, triangular gage block base Indicator, triangular gage block base Optical Comparators3 X-Axis Y-Axis Angle Up to 12 in Up to 12 in Up to 90° (250 + 91L) µin (250 + 91L) µin 0.029° Glass scale Angle blocks Rulers3 Up to 72 in 0.013 in Standard ruler
to 107 in
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 17 of 37 Parameter/Equipment Range CMC2 (±) Comments Radius Gages3 Up to 0.75 in 1300 µin Optical comparator & overlay Angle Gages3 Up to 180° 0.044° Optical comparator & vernier Coating/Electromagnetic Thickness3 Up to 120 mils 0.25 mils Shims Tape Measures3 Up to 40 in Up to 100 ft 0.013 in 0.062 in Standard ruler Standard tape III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 6, 12 (±) Comments AC Current – Measure3 Up to 1 A (1 to 3) A 60 Hz to 1 kHz 0.16 % + 0.4 mA 0.14 % + 1.8 mA HP 34401A AC Current – Generate3 (29 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 10) A (10 to 20) A (16 to 150) A (150 to 1000) A 45 Hz to 1 kHz (45 to 440) Hz 0.13 % + 0.1 µA 0.10 % + 0.15 µA 0.07 % + 2 µA 0.083 % + 20 µA 0.10 % + 100 µA 0.21 % + 2 mA 0.21 % + 5 mA 1 % + 0.25 A 1 % + 0.9 A Fluke 5522A Using 50 turn coil AC Voltage – Generate3 (1 to 330) mV (0.330 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 1 kHz (1 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.018 % + 8 µV 0.018 % + 60 µV 0.017 % + 0.6 mV 0.023 % + 2 mV 0.023 % + 6 mV 0.046 % + 10 mV 0.040 % + 10 mV Fluke 5522A
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 18 of 37 Parameter/Range Frequency CMC2, 6, 12 (±) Comments AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V Up to 10 kV Up to 50 kV 60 Hz to 3 kHz 0.063 % + 40 µV 0.063 % + 300 µV 0.062 % + 3 mV 0.064 % + 30 mV 0.075 % + 230 mV 0.12 % + 100 mV 0.1 % + 400 mV HP 34401A Vitrek 4700 w/ HVL-70 Parameter/Equipment Range CMC2, 6, 12 (±) Comments Capacitance – Generate3 Low High (0.22 to 3.3) nF (3.3 to 33) nF (33 to 330) nF (330 to 3300) nF (3.3 to 33) µF (33 to 330) µF (330 to 3300) µF (3.3 to 110) mF 0.5 % + 10 pF 0.26 % + 100 pF 0.26 % + 300 pF 0.26 % + 3 nF 0.4 % + 30 nF 0.45 % + 300 nF 0.45 % + 3 µF 1.1 % + 10 µF Fluke 5522A DC Current – Generate3 (0 to 330) µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 3 A (1.1 to 11) A (11 to 20.5) A (10 to 150) A (150 to 1000) A 0.015 % + 20 nA 0.010 % + 50 nA 0.014 % + 250 nA 0.010 % + 2.5 µA 0.038 % + 40 µA 0.050 % + 500 µA 0.1 % + 750 µA 0.5 % + 0.14 A 0.5 % + 0.5 A Fluke 5522A Using 50 turn coil DC Current – Measure3 Up to 10 mA (10 to 100) mA 100 mA to 1 A (1 to 3) A 0.075 % + 6 µA 0.051 % + 5 µA 0.11 % + 100 µA 0.13 % + 600 µA HP 34401A DC Voltage – Generate3 (0 to 330) mV Up to 3.3 V Up to 33 V (30 to 330) V (100 to 1000) V 0.002 % + 1 µV 0.0012 % + 2 µV 0.0013 % + 20 µV 0.0018 % + 0.15 mV 0.0019 % + 1.5 mV Fluke 5522A
to 750 V
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 19 of 37 Parameter/Equipment Range CMC2, 6, 12 (±) Comments DC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 10 kV Up to 70 kV 0.0054 % + 3.5 µV 0.0042 % + 7 µV 0.0037 % + 50 µV 0.0048 % + 600 µV 0.0049 % + 10 mV 0.041 % + 30 mV 0.049 % + 200 mV HP 34401A Vitrek 4700 w/ HVL- 70 Oscilloscopes3 Square Wave Amplitude: 50 Ω at 1 kHz 1 MΩ at 1 kHz DC Voltage Amplitude: 50 Ω Load 1 MΩ Load Level Sine Wave: Frequency Amplitude Flatness Time Markers: 50 Ω Load Rise Time – Generate 1 mV to 6.6 V pk-pk 1 mv to 130 V pk-pk Up to ± 6.6 V Up to ± 130 V Up to 1100 MHz 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 1 ns 1 kHz to 2 MHz (200 to 300) ps (2 to 10) MHz (200 to 300) ps 0.34 % + 40 µV 0.25 % + 40 µV 0.25 % + 40 µV 0.05 % + 40 µV 2.5 parts × 10 6 2.8 % + 300 µV 4.2 % + 300 µV 4.6 % + 300 µV 6.4 % + 300 µV 7.4 % + 300 µV 2.7 % + 100 µV 3.0 % + 100 µV 4.6 % + 100 µV 5.5 % + 100 µV 28 + 1000t µs/s 3.2 µs/s 120 ps 120 ps Fluke 5522A/ SC1100 t = time in seconds
to 70000 V
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 20 of 37 Parameter/Equipment Range CMC2, 6, 12 (±) Comments Electrical Calibration of Temperature Controllers3 Thermocouple types J, K, T & E PT385, 100 Ω (-200 to < 0) °C (0 to 1370) °C (-200 to 800) °C 1.2 °C 0.85 °C 0.66 °C Fluke 725 Resistance – Generate3 Up to 330 Ω (330 to 3300) Ω (3300 to 33 000) Ω (33 to 330) kΩ (330 to 3300) kΩ (3.3 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.065 % + 20 mΩ 0.029 % + 100 mΩ 0.029 % + 1.0 Ω 0.0037 % + 10 Ω 0.0063 % + 150 Ω 0.026 % + 2500 Ω 0.063 % + 3.0 kΩ 0.14 % + 100 kΩ 0.14 % + 500 kΩ Fluke 5522A Resistance – Measure3 Up to 100 Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 0.066 % + 4 mΩ 0.031 % + 10 mΩ 0.031 % + 100 mΩ 0.011 % + 1 Ω 0.012 % + 10 Ω 0.048 % + 100 Ω 0.8 % + 10 kΩ HP 34401A Electrical Simulation of RTD 3 PT385, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 630) °C (630 to 800) °C 0.058 °C 0.17 °C 0.12 °C 0.14 °C 0.28 °C Fluke 5522A
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 21 of 37 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Indicators3 Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0.0) °C (0.0 to 120) °C (120 to 400) °C 0.51 °C 0.16 °C 0.19 °C 0.20 °C 0.24 °C 0.28 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.20 °C 0.24 °C 0.40 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5522A Welding Devices3 (0 to 350) Amps DC (0 to 100) Volts DC (100 to 700) Feed Rate IPM 0.87 ADC 0.012 VDC 3.6 IPM Load bank, current shunt, DMM IV. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments POVA (Piston/Plunger Operated Volumetric Apparatus)3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (.1 to 50) µL (50 to 100) µL (100 to 500) µL (500 to 1000) µL (1000 to 5000) µL (5000 to 10 000) µL (10 000 to 20 000) µL (20 000 to 50 000) µL 0.31 µL 0.31 µL 0.56 µL 0.72 µL 5.4 µL 18 µL 30 µL 72 µL Gravimetric method
22--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 22 of 37 V. Mechanical Parameter/Equipment Range CMC2, 7, 11 (±) Comments Balances3 Up to 20 g Up to 200 g Up to 200 g Up to 1000 g Up to 5000 g Up to 20 g Up to 200 g Up to 1000 g Up to 5000 g Up to 10 000 g Up to 20 000 g 0.11 mg 0.69 mg 1.3 mg 6.6 mg 34 mg 0.81 mg 4.8 mg 24 mg 130 mg 370 mg 460 mg Class 1 weights Class 2 weights Class 4 weights Force – Measuring Equipment3 Tension/Compression Compression Tension Up to 100 lbf (100 to 1000) lbf (1000 to 10 000) lbf (10 000 to 50 000) lbf (10 000 to 100 000) lbf (50 000 to 500 000) lbf (100 to 1000) lbf (1000 to 10 000) lbf (10 000 to 50 000) lbf (10 000 to 100 000) lbf 0.0064 lbf 0.26 % Indication 0.24 % Indication 0.33 % Indication 0.20 % Indication 0.4 % Indication 0.23 % Indication 0.23 % Indication 0.29 % Indication 0.20 % Indication Class F weights w/ load cells
to 20000 g
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 23 of 37 Parameter/Equipment Range CMC2, 11 (±) Comments Optical Tachometer3 Up to 200 FPM Up to 3000 FPM Up to 29 999 FPM 0.12 FPM 0.39 FPM 3.9 FPM Calibrated strobe (FPM = Flashes per minute) Pressure Measuring Equipment – Gages, Transducers & Transmitters3 Up to 300 psig Up to 3000 psig Up to 5000 psig Up to 10 000 psig Up to 30 000 psig Up to 2 in H 2O Up to 300 psig Up to 3000 psig Up to 10 000 psig (10 to 17) psia 0.18 psig 3.8 psig 3.9 psig 12 psig 43 psig 0.0026 in H 2O 0.051 psig 0.4 psig 1.3 psig 0.000 78 psia Digital pressure gage Dwyer hook gage GE/Pace 1003 Barometric reference Scales3 Up to 10 lb Up to 20 lb Up to 50 lb Up to 100 lb Up to 200 lb Up to 500 lb Up to 1000 lb Up to 5000 lb Up to 20 000 lb 0.000 25 lb 0.000 25 lb 0.0063 lb 0.0063 lb 0.0064 lb 0.0064 lb 0.18 lb 0.19 lb 0.21 lb Class 4 weights Class F weights
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 24 of 37 Parameter/Equipment Range CMC2, 11 (±) Comments Torque Wrenches – Measure3 (1 to 10) lbf⋅in (10 to 50) lbf⋅in (30 to 400) lbf⋅in (80 to 1000) lbf⋅in (240 to 3000) lbf⋅in (1200 to 6000) lbf⋅in (2400 to 12 000) lbf⋅in 0.33 lbf⋅in 0.17 lbf⋅in 1.8 lbf⋅in 5.1 lbf⋅in 21 lbf⋅in 23 lbf⋅in 58 lbf⋅in CDI/Norbar torque calibrator Norbar torque calibrator Vacuum Measuring Equipment – Gauges 3 Up to 13 psig 0.033 psig Druck DPI 610 Rotations Speed – Measurement3 Contact: Up to 200 RPM (200 to 3000) RPM (3000 to 20 000) RPM Optical: Up to 3000 RPM (3000 to 30 000) RPM 0.67 RPM 13 RPM 16 RPM 0.5 RPM 5.0 RPM Monarch PLT200 Indirect Verification of Rockwell Hardness Testers3 HRB: Low Medium High HRC: Low Medium High 1.0 HRB 0.65 HRB 0.49 HRB 0.45 HRC 0.36 HRC 0.37 HRC Indirect verification Indirect Verification of Brinell Hardness Testers3 HBW 10/500: Low HBW 10/3000: High 4.0 HBW 4.8 HBW Indirect verification
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 25 of 37 VI. Thermodynamic Parameter/Equipment Range CMC2, 11 (±) Comments Temperature – Measuring Equipment3 (-100 to 300) °C (-148 to 572) °F 0.09 °C 0.16 °F Hart 1502A/5614 PRT or Fluke 1523 Temperature –Measure3 (-100 to 600) °C (-148 to 1112) °F (> 600 to 1200) °C (> 1112 to 2192) °F 1.5 °C 2.7 °F 10 °C 18 °F Fluke 51 or 725 with thermocouple IR Thermometer3 (-20 to 150) °C (Amb + 10 to 400) °C 1.1 °C 2.1 °C Mikron M340 (lab only) Omega BB703 Emissivity ≈ 0.95 Wavelength (8 to 14) µm Humidity – Measure & Measuring Equipment3 (20 to 90) % RH 3.4 % RH SensoScientific B13-200 VII. Time & Frequency Parameter/Equipment Range CMC2, 6, 11 (±) Comments Frequency – Measuring Equipment3 Up to 1100 MHz 2.5 parts × 106 Fluke 5522A/SC1100 Frequency – Measure3 40 Hz to 300 kHz 0.014 % Indication HP 34401 Timers & Stopwatches3 Up to 1 hr (> 1 to 24) hr 0.14 s 0.59 s Reference stopwatch Stroboscopes3 Up to 3600 FPM Up to 30 000 FPM 0.11 FPM 0.72 FPM Universal counter
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 26 of 37 SATELLITE ALDINGER COMPANY 8023 Interstate 30 Little Rock, AR 72209 Dustin Detten Phone: 214 638 1808 CALIBRATION I. Chemical Parameter/Equipment Range CMC2 (±) Comments Conductivity Meters3 1 µS/cm 10 µS/cm 100 µS/cm 1000 µS/cm 10 000 µS/cm 100 000 µS/cm 0.55 µS/cm 0.41 µS/cm 2.8 µS/cm 20 µS/cm 190 µS/cm 1900 µS/cm Reference conductivity standards pH Meters3 Electrical Calibration Probe/Meter Standardization (0 to 14) pH 4 pH 7 pH 10 pH 0.015 pH 0.030 pH 0.030 pH 0.030 pH mV/pH calibrator Reference buffer standards II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Calipers3 Up to 24 in (24 to 48) in Up to 48 in (48 to 96) in 550 µin 1100 µin 77 µin 1500 µin Gage blocks (field) Gage blocks (lab)
27--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 27 of 37 Parameter/Equipment Range CMC2, 4 (±) Comments Dial & Test Indicators3 Up to 1 in Up to 3 in Up to 3 in 20 µin 59 µin 90 µin Gage blocks (lab) Gage blocks, ULM, SuperMicrometer 10 (lab) Gage blocks (field) Height Gages3 Up to 48 in Up to 48 in 280 µin 89 µin Gage blocks (field) Gage blocks (lab) Levels3 Up to 12 in (40 + 14L) µin Surface plate, granite square Micrometers3 Up to 4 in (4 to 24) in (24 to 48) in Up to 4 in (4 to 24) in (24 to 96) in 92 µin 550 µin 1100 µin 15 µin 60 µin 1500 µin Gage blocks (field) Gage blocks (lab) Protractors3 Up to 90° 0.049° Surface plate, angle blocks, sine bar w/ gage blocks Surface Plates – Flatness & Repeatability3 Indicator Stands Up to 107 in DL (-0.002 to 0.002) in (-0.002 to 0.002) in (-0.01 to 0.01) in (48 + 0.41DL) µin 31 µin 45 µin 580 µin Leveling system (DL is diagonal of the plate) Repeat reading gage Repeat reading gage, triangular gage block base Indicator, triangular gage block base Optical Comparators3 X-Axis Y-Axis Angle Up to 12 in Up to 12 in Up to 90° (250 + 91L) µin (250 + 91L) µin 0.029° Glass scale Angle blocks Rulers3 Up to 72 in 0.013 in Standard ruler
to 107 in
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 28 of 37 Parameter/Equipment Range CMC2, 4 (±) Comments Radius Gages3 Up to 0.75 in 1300 µin Optical comparator & overlay Angle Gages3 Up to 180° 0.044° Optical comparator & vernier Coating/Electromagnetic Thickness3 Up to 120 mils 0.25 mils Shims Tape Measures3 Up to 40 in Up to 100 ft 0.013 in 0.062 in Standard ruler Standard tape III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 6, 12 (±) Comments AC Current – Measure3 Up to 1 A (1 to 3) A 60 Hz to 1 kHz 0.16 % + 0.4 mA 0.14 % + 1.8 mA HP 34401A AC Current – Generate3 (29 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 10) A (10 to 20) A (16 to 150) A (150 to 1000) A 45 Hz to 1 kHz (45 to 440) Hz 0.13 % + 0.1 µA 0.10 % + 0.15 µA 0.07 % + 2 µA 0.083 % + 20 µA 0.10 % + 100 µA 0.21 % + 2 mA 0.21 % + 5 mA 1 % + 0.25 A 1 % + 0.9 A Fluke 5522A Using 50 turn coil AC Voltage – Generate3 (1 to 330) mV (0.330 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 1 kHz (1 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.018 % + 8 µV 0.018 % + 60 µV 0.017 % + 0.6 mV 0.023 % + 2 mV 0.023 % + 6 mV 0.046 % + 10 mV 0.040 % + 10 mV Fluke 5522A
29--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 29 of 37 Parameter/Range Frequency CMC2, 6, 12 (±) Comments AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V Up to 10 kV Up to 50 kV 60 Hz to 3 kHz 0.063 % + 40 µV 0.063 % + 300 µV 0.062 % + 3 mV 0.064 % + 30 mV 0.075 % + 230 mV 0.12 % + 100 mV 0.1 % + 400 mV HP 34401A Vitrek 4700 w/ HVL-70 Parameter/Equipment Range CMC2, 6, 12 (±) Comments Capacitance – Generate3 Low High (0.22 to 3.3) nF (3.3 to 33) nF (33 to 330) nF (330 to 3300) nF (3.3 to 33) µF (33 to 330) µF (330 to 3300) µF (3.3 to 110) mF 0.5 % + 10 pF 0.26 % + 100 pF 0.26 % + 300 pF 0.26 % + 3 nF 0.4 % + 30 nF 0.45 % + 300 nF 0.45 % + 3 µF 1.1 % + 10 µF Fluke 5522A DC Current – Generate3 (0 to 330) µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 3 A (1.1 to 11) A (11 to 20.5) A (10 to 150) A (150 to 1000) A 0.015 % + 20 nA 0.010 % + 50 nA 0.014 % + 250 nA 0.010 % + 2.5 µA 0.038 % + 40 µA 0.050 % + 500 µA 0.1 % + 750 µA 0.5 % + 0.14 A 0.5 % + 0.5 A Fluke 5522A Using 50 turn coil DC Current – Measure3 Up to 10 mA (10 to 100) mA 100 mA to 1 A (1 to 3) A 0.075 % + 6 µA 0.051 % + 5 µA 0.11 % + 100 µA 0.13 % + 600 µA HP 34401A DC Voltage – Generate3 (0 to 330) mV Up to 3.3 V Up to 33 V (30 to 330) V (100 to 1000) V 0.002 % + 1 µV 0.0012 % + 2 µV 0.0013 % + 20 µV 0.0018 % + 0.15 mV 0.0019 % + 1.5 mV Fluke 5522A
to 750 V
30--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 30 of 37 Parameter/Equipment Range CMC2, 6, 12 (±) Comments DC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 10 kV Up to 70 kV 0.0054 % + 3.5 µV 0.0042 % + 7 µV 0.0037 % + 50 µV 0.0048 % + 600 µV 0.0049 % + 10 mV 0.041 % + 30 mV 0.049 % + 200 mV HP 34401A Vitrek 4700 w/ HVL- 70 Oscilloscopes3 Square Wave Amplitude: 50 Ω at 1 kHz 1 MΩ at 1 kHz DC Voltage Amplitude: 50 Ω Load 1 MΩ Load Level Sine Wave: Frequency Amplitude Flatness Time Markers: 50 Ω Load Rise Time – Generate 1 mV to 6.6 V pk-pk 1 mv to 130 V pk-pk Up to ± 6.6 V Up to ± 130 V Up to 1100 MHz 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 1 ns 1 kHz to 2 MHz (200 to 300) ps (2 to 10) MHz (200 to 300) ps 0.34 % + 40 µV 0.25 % + 40 µV 0.25 % + 40 µV 0.05 % + 40 µV 2.5 parts × 10 6 2.8 % + 300 µV 4.2 % + 300 µV 4.6 % + 300 µV 6.4 % + 300 µV 7.4 % + 300 µV 2.7 % + 100 µV 3.0 % + 100 µV 4.6 % + 100 µV 5.5 % + 100 µV 28 + 1000t µs/s 3.2 µs/s 120 ps 120 ps Fluke 5522A/ SC1100 t = time in seconds
to 70000 V
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 31 of 37 Parameter/Equipment Range CMC2, 6, 12 (±) Comments Electrical Calibration of Temperature Controllers3 Thermocouple types J, K, T & E PT385, 100 Ω (-200 to < 0) °C (0 to 1370) °C (-200 to 800) °C 1.2 °C 0.85 °C 0.66 °C Fluke 725 Resistance – Generate3 Up to 330 Ω (330 to 3300) Ω (3300 to 33 000) Ω (33 to 330) kΩ (330 to 3300) kΩ (3.3 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.065 % + 20 mΩ 0.029 % + 100 mΩ 0.029 % + 1.0 Ω 0.0037 % + 10 Ω 0.0063 % + 150 Ω 0.026 % + 2500 Ω 0.063 % + 3.0 kΩ 0.14 % + 100 kΩ 0.14 % + 500 kΩ Fluke 5522A Resistance – Measure3 Up to 100 Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 0.066 % + 4 mΩ 0.031 % + 10 mΩ 0.031 % + 100 mΩ 0.011 % + 1 Ω 0.012 % + 10 Ω 0.048 % + 100 Ω 0.8 % + 10 kΩ HP 34401A Electrical Simulation of RTD3 PT385, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 630) °C (630 to 800) °C 0.058 °C 0.17 °C 0.12 °C 0.14 °C 0.28 °C Fluke 5522A
32

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 32 of 37 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Indicators3 Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0.0) °C (0.0 to 120) °C (120 to 400) °C 0.51 °C 0.16 °C 0.19 °C 0.20 °C 0.24 °C 0.28 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.20 °C 0.24 °C 0.40 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C Fluke 5522A Welding Devices3 (0 to 350) Amps DC (0 to 100) Volts DC (100 to 700) Feed Rate IPM 0.87 ADC 0.012 VDC 3.6 IPM Load bank, current shunt, DMM IV. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments POVA (Piston/Plunger Operated Volumetric Apparatus)3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (0.1 to 50) µL (50 to 100) µL (100 to 500) µL (500 to 1000) µL (1000 to 5000) µL (5000 to 10 000) µL (10 000 to 20 000) µL (20 000 to 50 000) µL 0.31 µL 0.31 µL 0.56 µL 0.72 µL 5.4 µL 18 µL 30 µL 72 µL Gravimetric method
33--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 33 of 37 V. Mechanical Parameter/Equipment Range CMC2, 11 (±) Comments Balances3 Up to 20 g Up to 200 g Up to 200 g Up to 1000 g Up to 5000 g Up to 20 g Up to 200 g Up to 1000 g Up to 5000 g Up to 10 000 g Up to 20 000 g 0.11 mg 0.69 mg 1.3 mg 6.6 mg 34 mg 0.81 mg 4.8 mg 24 mg 130 mg 370 mg 460 mg Class 1 weights Class 2 weights Class 4 weights Force – Measuring Equipment3 Tension/Compression Compression Tension Up to 100 lbf (100 to 1000) lbf (1000 to 10 000) lbf (10 000 to 50 000) lbf (10 000 to 100 000) lbf (50 000 to 500 000) lbf (100 to 1000) lbf (1000 to 10 000) lbf (10 000 to 50 000) lbf (10 000 to 100 000) lbf 0.0064 lbf 0.26 % Indication 0.24 % Indication 0.33 % Indication 0.20 % Indication 0.4 % Indication 0.23 % Indication 0.23 % Indication 0.29 % Indication 0.20 % Indication Class F weights w/ load cells
to 20000 g
34

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 34 of 37 Parameter/Equipment Range CMC2, 11 (±) Comments Optical Tachometer3 Up to 200 FPM Up to 3000 FPM Up to 29 999 FPM 0.12 FPM 0.39 FPM 3.9 FPM Calibrated strobe (FPM = Flashes per minute) Pressure Measuring Equipment – Gages, Transducers & Transmitters3 Up to 300 psig Up to 3000 psig Up to 5000 psig Up to 10 000 psig Up to 30 000 psig Up to 2 in H 2O Up to 300 psig Up to 3000 psig Up to 10 000 psig (10 to 17) psia 0.18 psig 3.8 psig 3.9 psig 12 psig 43 psig 0.0026 in H 2O 0.051 psig 0.4 psig 1.3 psig 0.000 78 psia Digital pressure gage Dwyer hook gage GE/Pace 1003 Barometric reference Scales3 Up to 10 lb Up to 20 lb Up to 50 lb Up to 100 lb Up to 200 lb Up to 500 lb Up to 1000 lb Up to 5000 lb Up to 20 000 lb 0.000 25 lb 0.000 25 lb 0.0063 lb 0.0063 lb 0.0064 lb 0.0064 lb 0.18 lb 0.19 lb 0.21 lb Class 4 weights Class F weights
35

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 35 of 37 Parameter/Equipment Range CMC2, 11 (±) Comments Torque Wrenches – Measure3 (1 to 10) lbf⋅in (10 to 50) lbf⋅in (30 to 400) lbf⋅in (80 to 1000) lbf⋅in (240 to 3000) lbf⋅in (1200 to 6000) lbf⋅in (2400 to 12 000) lbf⋅in 0.33 lbf⋅in 0.17 lbf⋅in 1.8 lbf⋅in 5.1 lbf⋅in 21 lbf⋅in 23 lbf⋅in 58 lbf⋅in CDI/Norbar torque calibrator Norbar torque calibrator Vacuum Measuring Equipment – Gauges 3 Up to 13 psig 0.033 psig Druck DPI 610 Rotations Speed – Measurement3 Contact: Up to 200 RPM (200 to 3000) RPM (3000 to 20 000) RPM Optical: Up to 3000 RPM (3000 to 30 000) RPM 0.67 RPM 13 RPM 16 RPM 0.5 RPM 5.0 RPM Monarch PLT200 Indirect Verification of Rockwell Hardness Testers3 HRB: Low Medium High HRC: Low Medium High 1.0 HRB 0.65 HRB 0.49 HRB 0.45 HRC 0.36 HRC 0.37 HRC Indirect verification Indirect Verification of Brinell Hardness Testers3 HBW 10/500: Low HBW 10/3000: High 4.0 HBW 4.8 HBW Indirect verification
36

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 36 of 37 VI. Thermodynamic Parameter/Equipment Range CMC2, 11 (±) Comments Temperature – Measuring Equipment3 (-100 to 300) °C (-148 to 572) °F 0.09 °C 0.16 °F Hart 1502A/5614 PRT or Fluke 1523 Temperature –Measure3 (-100 to 600) °C (-148 to 1112) °F (> 600 to 1200) °C (> 1112 to 2192) °F 1.5 °C 2.7 °F 10 °C 18 °F Fluke 51 or 725 with thermocouple IR Thermometer3 (-20 to 150) °C (Amb + 10 to 400) °C 1.1 °C 2.1 °C Mikron M340 (lab only) Omega BB703 Emissivity ≈ 0.95 Wavelength (8 to 14) µm Humidity – Measure & Measuring Equipment3 (20 to 90) % RH 3.4 % RH SensoScientific B13-200 VII. Time & Frequency Parameter/Equipment Range CMC2, 6, 11 (±) Comments Frequency – Measuring Equipment3 Up to 1100 MHz 2.5 parts × 106 Fluke 5522A/SC1100 Frequency – Measure3 40 Hz to 300 kHz 0.014 % Indication HP 34401 Timers & Stopwatches3 Up to 1 hr (> 1 to 24) hr 0.14 s 0.59 s Reference stopwatch Stroboscopes3 Up to 3600 FPM Up to 30 000 FPM 0.11 FPM 0.72 FPM Universal counter __________________________________________
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.01) Revised 07/09/2025 Page 37 of 37 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. , resolution, repeatability) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches and R is the numerical value of the resolution of the device in microinches unless otherwise noted. 5 Adjustable thread rings are set to applicable specification using calibrated master set plug gages. 6 CMC for the HP 34401 is based on 1- year specifications within a temperature range of 18 ° C to 28 °C. Field calibrations will be performed within 18 °C to 28 °C, 30 % to 55 % humidity. 7 Where ranges are not specified, the CMC stated is for the cardinal points only. 8 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted. 9 "Supermicrometer" is a registered trademark with a last listed owner of Pratt & Whitney Measurement Systems, Inc., Connecticut U.S.A. 10 This scope meets A2LA’s P112 Flexible Scope Policy. 11 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 12 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 13 Aldinger Company is also doing business as Utah Scale Center for field calibration services, with administrative offices located at 199 W Cottage Avenue, Sandy, UT 84070.
38ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.