Meyer Tool, Inc., Flow Measurement Center
3015 Garrard Avenue, 45225, Cincinnati, OH, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3479.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3479.01) 10/14/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MEYER TOOL, INC., FLOW MEASUREMENT CENTER
3015 Garrard Avenue
Cincinnati, OH 45225
Brandon Handy Phone: 513 853 4533
CALIBRATION
Valid To: July 31, 2027 Certificate Number: 3479.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Air Flow – Measure3
(0.0003 to 0.10) lbm/s
(0.050 to 1.20) lbm/s
0.24 %
0.33 %
Flow standards
II. Mechanical
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Pressure – Measuring
Equipment & Measure
(3.5 to 100) inches of water at 20 °C
(5 to 25) psig
(25 to 100) psig
(12 to 16) psia
0.032 %
0.049 %
0.052 %
0.028 %
Gauge mode
Absolute mode | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3479.01) 10/14/2025 Page 2 of 2
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Temperature –
PRT/Thermistors
Calibration3
(440 to 570) °R
0.022 %
SPRT &
temperature bath
Dew/Frost Point –
Measure
(23 to 50) °F
3.6 °F
Fluke 5128A
________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, the value is defined as the percentage of reading.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | 440 to 570 °R |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.