FindTestingLabs
Registers collected 2026-08-22.See collection dates
United States

Oneida Research Services

4201 Pottsville Pike, Suite 420, 19605, Reading, PA, United States

A2LA|2930.01ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
4
Locations
1

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Oneida Research Services?

Claim this profile to keep it accurate.

Claim this profile

Register record

A2LACollected
2930.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

2930.01

View scope

Accredited scope, certificate 2930.01

DisciplineMethodMatrixRange
materialsJESD22-A110; JESD22-A118; AEC-Q100; JESD22-A108; JESD22-A102; AEC-Q100; AEC-Q101; JESD22-A113; J-STD-020; J-STD-035; AEC-Q100; AEC-Q101; AEC-Q200; JSTD-002; MIL-STD-750 Method 2026; MIL-STD-883 Method 2003; GR-326-CORE; GR-468-CORE; AEC-Q100; AEC-Q101; MIL-STD-202 Method 212; MIL-STD-750 Method 2006; MIL-STD-883 Method 2001; AEC-Q101; AEC-Q200; JESD22-B107; MIL-STD-202 Method 215; MIL-STD-750 Method 1022; MIL-STD-883 Method 2015; AEC-Q101; AEC-Q200; JESD22-B106; MIL-STD-202 Method 210; MIL-STD-750 Method 2031; MIL-STD-883 Method 2036; JESD22-B101; MIL-STD-750 Method 2071; MIL-STD-883 Method 2009; JESD22-B100; MIL-STD-883 Method 2016; MIL-STD-750 Method 2066-to 50000 G’s
materialsAEC-Q101; JESD22-A108; MIL-STD-750 Method 1042; MIL-STD-883 Method 1005; JESD22-A106; MIL-STD-202 Method 107; MIL-STD-750 Method 1056; MIL-STD-883 Method 1011; AEC-Q100-008; MIL-STD-750 Method 1036; MIL-STD-883 Methods 1006, 1005; GR-468-CORE; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-202 Method 106; MIL-STD-750 Method 1021; MIL-STD-810 Method 507; MIL-STD-883 Method 1004; JESD22-A101; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-750 Method 1021; MIL-STD-883 Method 1004; AEC-Q100, AEC-Q101, AEC-Q200; GR-468-CORE; JESD22-B104; MIL-STD-202 Method 213, Cond (A-F and J); MIL-STD-750 Method 2016; MIL-STD-883 Method 2002; ASTM D4169; GR-63-CORE sections 5.3.3 Parts I and II; AEC-Q100, AEC-Q101; JESD22-B103; MIL-STD-202 Method 201; MIL-STD-750 Method 2056; MIL-STD-883 Method 2007; MIL-STD-202 Method 214, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-883 Method 2026, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-750 Method 2046; ASTM D999 Method A1 Repetitive Shock (Vertical Motion); ASTM D4169 Schedule D Stacked Vibration, Schedule E Vehicle Vibration, Schedule F Loose Load Vibration; GR-63-CORE--65 to 4000 °C; % RH; G’s; Hz
mechanical---
mechanicalJESD22-A108; MIL-STD-202 Method 108; MIL-STD-750 Methods 1026; MIL-STD-750 Methods 1038; MIL-STD-750 Methods 1039; MIL-STD-750 Methods 1040; MIL-STD-750 Methods 1048; MIL-STD-883 Methods 1005; MIL-STD-883 Methods 1015; MIL-STD-883 Methods 1016; AEC-Q100; AEC-Q200; GR-468-CORE (3.3.2.1); JESD22-A103 Cond A-G; MIL-STD-202 Method 108; MIL-STD-750 Method 1031; MIL-STD-883 Method 1008; GR-468-CORE (3.3.2.1); JESD22-A119; JESD22-A119, Cond A-C; GR-468-CORE; JESD22-A104; MIL-STD-750 Methods 1051; MIL-STD-750 Methods 1055; MIL-STD-883 Method 1010; JESD22-A105; MIL-STD-883 Method 1007Medical devices-65 to 300 °C

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

4201 Pottsville Pike, Suite 420, Reading, PA, 19605, US

40.33534, -75.92795

Open in Maps

Accreditation data collected from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.