Oneida Research Services

4201 Pottsville Pike, Suite 420, 19605, Reading, PA, United States

Visit website
A2LA 2930.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D999
ASTM D4169

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

2930.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 2930.01

LineMethodMatrixRange
1JESD22-A108; MIL-STD-202 Method 108; MIL-STD-750 Methods 1026; MIL-STD-750 Methods 1038; MIL-STD-750 Methods 1039; MIL-STD-750 Methods 1040; MIL-STD-750 Methods 1048; MIL-STD-883 Methods 1005; MIL-STD-883 Methods 1015; MIL-STD-883 Methods 1016; AEC-Q100; AEC-Q200; GR-468-CORE (3.3.2.1); JESD22-A103 Cond A-G; MIL-STD-202 Method 108; MIL-STD-750 Method 1031; MIL-STD-883 Method 1008; GR-468-CORE (3.3.2.1); JESD22-A119; JESD22-A119, Cond A-C; GR-468-CORE; JESD22-A104; MIL-STD-750 Methods 1051; MIL-STD-750 Methods 1055; MIL-STD-883 Method 1010; JESD22-A105; MIL-STD-883 Method 1007Medical devicesSee scope document
2AEC-Q101; JESD22-A108; MIL-STD-750 Method 1042; MIL-STD-883 Method 1005; JESD22-A106; MIL-STD-202 Method 107; MIL-STD-750 Method 1056; MIL-STD-883 Method 1011; AEC-Q100-008; MIL-STD-750 Method 1036; MIL-STD-883 Methods 1006, 1005; GR-468-CORE; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-202 Method 106; MIL-STD-750 Method 1021; MIL-STD-810 Method 507; MIL-STD-883 Method 1004; JESD22-A101; MIL-STD-202 Method 103; JESD22-A100; MIL-STD-750 Method 1021; MIL-STD-883 Method 1004; AEC-Q100, AEC-Q101, AEC-Q200; GR-468-CORE; JESD22-B104; MIL-STD-202 Method 213, Cond (A-F and J); MIL-STD-750 Method 2016; MIL-STD-883 Method 2002; ASTM D4169; GR-63-CORE sections 5.3.3 Parts I and II; AEC-Q100, AEC-Q101; JESD22-B103; MIL-STD-202 Method 201; MIL-STD-750 Method 2056; MIL-STD-883 Method 2007; MIL-STD-202 Method 214, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-883 Method 2026, Cond 1 (A-H), and Cond 2 (A-G); MIL-STD-750 Method 2046; ASTM D999 Method A1 Repetitive Shock (Vertical Motion); ASTM D4169 Schedule D Stacked Vibration, Schedule E Vehicle Vibration, Schedule F Loose Load Vibration; GR-63-CORE-See scope document
3JESD22-A110; JESD22-A118; AEC-Q100; JESD22-A108; JESD22-A102; AEC-Q100; AEC-Q101; JESD22-A113; J-STD-020; J-STD-035; AEC-Q100; AEC-Q101; AEC-Q200; JSTD-002; MIL-STD-750 Method 2026; MIL-STD-883 Method 2003; GR-326-CORE; GR-468-CORE; AEC-Q100; AEC-Q101; MIL-STD-202 Method 212; MIL-STD-750 Method 2006; MIL-STD-883 Method 2001; AEC-Q101; AEC-Q200; JESD22-B107; MIL-STD-202 Method 215; MIL-STD-750 Method 1022; MIL-STD-883 Method 2015; AEC-Q101; AEC-Q200; JESD22-B106; MIL-STD-202 Method 210; MIL-STD-750 Method 2031; MIL-STD-883 Method 2036; JESD22-B101; MIL-STD-750 Method 2071; MIL-STD-883 Method 2009; JESD22-B100; MIL-STD-883 Method 2016; MIL-STD-750 Method 2066-to 50000 G’s
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited ONEIDA RESEARCH SERVICES, INC. Reading, PA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 29th day of September 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2930.01 Valid to November 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4201 Pottsville Pike, Suite 420, Reading, PA, 19605, US

40.33534, -75.92795

Open in Maps

Accreditation data refreshed from the A2LA register on .