Registers refreshed 2026-11-20.See refresh dates
United States

Triax Cal

127 Walters Avenue, 08638, Ewing, NJ, United States

Visit website
A2LA 7365.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 7365.01 · 2 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7365.01) 8/27/2024 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO 17025:2017 TRIAX CAL LLC 127 Walters Avenue Ewing, NJ, 08638 Paul Bamburak Phone: 609 882 0366 CALIBRATION Valid To: September 30, 2026 Certificate Number: 7365.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Mechanical Parameter/Equipment Range CMC2 (±) Comments Vibration General Purpose – Sensitivity Magnitude Accelerometers (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz 2.2 % rdg 1.7 % rdg 1.3 % rdg 1.4 % rdg 1.7 % rdg Reference accelerometer, back- to-back comparison method __________________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy.
2ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

127 Walters Avenue, Ewing, NJ, 08638, US

40.26881, -74.80069

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.