Registers refreshed 2026-11-20.See refresh dates
Italy

PLUS LAB SRL

Via Portico 4, 24050, Orio al Serio, Italy

Visit website
ACCREDIA 01882ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
8
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 13230-2
EN 13230-4
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-57
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-3-3
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

2 lines
ACCREDIA

ISO/IEC 17025

Active

01882

View scope

Accredited scope, certificate 01882

LineMethodMatrixRange
1CEI EN 60068-2-57:2014; EN 60068-2-57:2013; IEC 60068-2-57:2013; CEI EN IEC 60068-3-3:2020; EN IEC 60068-3-3:2019; IEC 60068-3-3:2019; CEI EN 60068-2-27:2012; EN 60068-2-27:2009; IEC 60068-2-27:2008; CEI EN 60068-2-6:2009; EN 60068-2-6:2008; IEC 60068-2-6:2007; CEI EN 60068-2-64:2012/A1:2020; EN 60068-2-64:2008/A1:2019; IEC 60068-2-64:2008/AMD1:2019; RFI TCAR SF AR 07 008 A 2016; RFI TCAR SF AR 07 002 E 2015; CEI EN 61373:2012; EN 61373:2010/AC:2017; IEC 61373:2010/COR1:2011; RFI TCAR SF AR 07 005 B 2008; RFI TCAR SF AR 03 002 F 2017; EN 13230-2:2016Apparecchiature elettriche ed elettroniche/Electric and electronic equipment; Apparecchiature elettriche, elettroniche e meccaniche, componenti e materiali/Electric, electronic and mechanical equipment, components and materials; Giunzioni incollate/Glued joints; Materiale rotabile/Rolling stock equipment; Rotaie saldate con procedura alluminotermica/Alluminothermic welding of rails; Traverse marca 'RFI 230', 'RFI 240' e 'RFI 260' in calcestruzzo vibrato, armato e precompresso/Sleepers type 'RFI 230', 'RFI 240' and 'RFI 260' in vibrated, reinforced and prestressed concrete; Traverse monoblocco precompresse di calcestruzzo/Prestressed monoblock concrete sleepers1 to 2000 Hz
2EN 13230-4:2016/A1:2020; RFI TCAR SF AR 03 003 F 2018 par III.2.3 + EN 13230-4:2016/A1:2020; RFI TCAR SF AR 03 003 F 2018 par III.2.3 + UNI EN 13230-4:2020-20 to 900 kN

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Portico 4, Orio al Serio, 24050, IT

45.67623, 9.69296

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.