Registers refreshed 2026-11-20.See refresh dates
United States

The Scale People Inc., dba The Lab People

9693-C Gerwig Lane, 21046, Columbia, MD, United States

Visit website
A2LA 1452.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1452.01 · 15 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 1 of 14 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 THE SCALE PEOPLE, INC., DBA THE LAB PEOPLE INC. 9693-C Gerwig Lane Columbia, MD 21046 Amanda Beard Phone: 410 309 5880 CALIBRATION Valid To: December 31, 2026 Certificate Number: 1452.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory at the location listed above as well as the one satellite laboratory location listed below1, 4: I. Chemical Parameter/Equipment Range CMC2, 5 (±) Comments CO23– Measure (0 to 2.5) % CO2 (2.6 to 5) % CO2 (5.1 to 20) % CO2 0.24 % CO2 0.25 % CO2 0.27 % CO2 Diamond Scientific Viasensor G100-010 O23– Measure (0 to 5) % O2 (5.1 to 20) % O2 0.31 % O2 0.31 % O2 Diamond Scientific Viasensor G100-010 II. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Distance3 – Measure Up to 6 in 0.002 in Height gauge or ruler
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 2 of 14 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Analytical Balances3 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 700 mg 1 g 2 g 2.1 g 3 g 5 g 6 g 7 g 10 g 30 g 50 g 100 g 150 g 200 g 230 g 250 g 400 g 500 g 0.0073 mg 0.0073 mg 0.0073 mg 0.0095 mg 0.012 mg 0.012 mg 0.012 mg 0.012 mg 0.012 mg 0.017 mg 0.039 mg 0.043 mg 0.043 mg 0.043 mg 0.040 mg 0.043 mg 0.056 mg 0.058 mg 0.093 mg 0.14 mg 0.29 mg 0.32 mg 0.58 mg 0.61 mg 0.60 mg 1.3 mg 1.4 mg E2 weights & Class 1 weights E2 weights & class 1 weights
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 3 of 14 Parameter/Equipment Range CMC2 (±) Comments Top Loader Balances3 100 g 200 g 500 g 620 g 700 g 1000 g 1500 g 1700 g 2000 g 2500 g 3000 g 3200 g 4000 g 5000 g 6000 g 7500 g 10 000 g 12 000 g 16 000 g 20 000 g 25 000 g 30 000 g 34 000 g 35 000 g 40 000 g 50 000 g 60 000 g 64 kg 150 kg 300 kg 2.2 mg 2.4 mg 3.6 mg 3.6 mg 3.8 mg 6.3 mg 6.7 mg 7.0 mg 24 mg 24 mg 25 mg 0.11 g 27 mg 21 mg 21 mg 0.03 g 0.22 g 0.21 g 0.23 g 0.27 g 0.28 g 0.28 g 0.28 g 0.28 g 0.25 g 0.34 g 0.30 g 0.30 g 16 g 24 g Class 2, class E2, or class F weights
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 4 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Torque3 – Measuring Equipment 1.78 lbf·in 10 lbf·in 100 lbf·in 800 lbf∙ft 0.0071 lbf·in 0.012 lbf·in 0.12 lbf·in 0.98 lbf∙ft Torque calibration system Force Measurement Equipment 3 – Tension & Compression 250 gf 2 lbf 10 lbf 25 lbf 50 lbf 100 lbf 200 lbf 500 lbf 1000 lbf 0.12 gf 0.0012 lbf 0.0025 lbf 0.011 lbf 0.023 lbf 0.045 lbf 0.11 lbf 0.23 lbf 0.45 lbf Standard weights Load cells or standard weights Scales3 1 lb 2 lb 5 lb 7 lb 10 lb 15 lb 20 lb 25 lb 50 lb 75 lb 100 lb 150 lb 200 lb 250 lb 500 lb 700 lb 1000 lb 1500 lb 2000 lb 2500 lb 5000 lb 7500 lb 10 000 lb 20 000 lb 50 000 lb 0.000 29 lb 0.000 50 lb 0.0013 lb 0.0011 lb 0.0033 lb 0.0033 lb 0.0050 lb 0.011 lb 0.012 lb 0.020 lb 0.023 lb 0.022 lb 0.042 lb 0.045 lb 0.13 lb 0.10 lb 0.25 lb 0.24 lb 0.50 lb 0.49 lb 1.3 lb 1.3 lb 2.5 lb 1.4 lb 11 lb Class F weights
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 5 of 14 Parameter/Equipment Range CMC2 (±) Comments Scales3 (cont) 10 kg 20 kg 25 kg 50 kg 60 kg 75 kg 80 kg 90 kg 100 kg 150 kg 200 kg 250 kg 270 kg 300 kg 400 kg 450 kg 500 kg 540 kg 600 kg 700 kg 720 kg 750 kg 800 kg 810 kg 900 kg 1000 kg 1250 kg 1350 kg 1500 kg 1700 kg 2000 kg 2500 kg 0.0024 kg 0.0031 kg 0.0036 kg 0.0051 kg 0.011 kg 0.011 kg 0.011 kg 0.011 kg 0.011 kg 0.021 kg 0.021 kg 0.021 kg 0.021 kg 0.042 kg 0.042 kg 0.042 kg 0.042 kg 0.042 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.21 kg 0.21 kg 0.21 kg 0.21 kg 0.21 kg Class F Weights Pipettes3 (0.1 to 1) µL (1 to 50) µL (50 to 100) µL (100 to 200) µL (200 to 500) µL (500 to 1250) µL (1250 to 2500) µL (2500 to 5000) µL (5000 to 12 500) µL (12 500 to 30 000) µL (30 000 to 50 000) µL (50 000 to 100 000) µL 0.032 µL 0.093 µL 0.29 µL 0.41 µL 0.45 µL 0.64 µL 1.2 µL 2.9 µL 4.9 µL 7.3 µL 8.4 µL 16 µL Gravimetric method
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 6 of 14 Parameter/Equipment Range CMC2 (±) Comments Load Cell Tension Compression (250 to 1500) lbf (>1500 to 5000) lbf (>5000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf (250 to 1500) lbf (>1500 to 5000) lbf (>5000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf 6.9 lbf 15 lbf 37 lbf 83 lbf 140 lbf 6.9 lbf 14 lbf 37 lbf 83 lbf 140 lbf Load cell Load cell Mass, Fixed Points 226.796 g (8 oz) 453.592 g (1 lb) 907.185 g (2 lb) 2267.962 g (5 lb) 4535.924 g (10 lb) 9071.85 g (20 lb) 11 339.809 g (25 lb) 22 679.619 g (50 lb) 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 25 kg 0.22 mg 0.26 mg 0.37 mg 1.0 mg 1.7 mg 100 mg 32 mg 62 mg 0.0023 mg 0.0023 mg 0.0023 mg 0.0024 mg 0.0023 mg 0.011 mg 0.0029 mg 0.0029 mg 0.0029 mg 0.0045 mg 0.0045 mg 0.0061 mg 0.013 mg 0.016 mg 0.023 mg 0.047 mg 0.22 mg 0.27 mg 0.38 mg 0.68 mg 2.8 mg 3.9 mg 9.9 mg 10 mg Modified substitution
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 7 of 14 Parameter/Equipment Range CMC2 (±) Comments Mass, Fixed Points 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 15 kg 20 kg 25 kg 0.0014 mg 0.0015 mg 0.0014 mg 0.0012 mg 0.0014 mg 0.0013 mg 0.0014 mg 0.0013 mg 0.0017 mg 0.0028 mg 0.0028 mg 0.0039 mg 0.011 mg 0.0092 mg 0.017 mg 0.032 mg 0.058 mg 0.22 mg 0.28 mg 0.50 mg 1.1 mg 2.9 mg 3.3 mg 6.1 mg 7.0 mg Double substitution Mass, Fixed Points 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 0.0014 mg 0.0015 mg 0.0014 mg 0.0012 mg 0.0014 mg 0.0013 mg 0.0014 mg 0.0013 mg 0.0017 mg 0.0028 mg 0.0028 mg 0.0039 mg 0.011 mg 0.0092 mg 0.017 mg 0.032 mg 0.058 mg Triple substitution
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 8 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Mass, Fixed Points (cont) 500 g 1 kg 2 kg 5 kg 10 kg 15 kg 20 kg 25 kg 0.22 mg 0.28 mg 0.50 mg 1.1 mg 2.9 mg 3.3 mg 6.1 mg 7.0 mg Triple substitution RPM3 (Non-Contact) – Measure (0.5 to 60) RPM (61 to 600) RPM (601 to 10 000) RPM (10 001 to 14 999) RPM (15 000 to 99 999) RPM (100 000 to 200 000) RPM 0.0070 RPM 0.17 RPM 2.8 RPM 5.9 RPM 28 RPM 90 RPM Monarch Tachometer 6125-010 IV. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity3 – Measure (0 to 90) % RH (90 to 100) % RH 2.1 % RH 3.5 % RH Vaisala HM40 meter with HMP113; temperature range (0 to 40) °C Temperature3 – Measure (-80 to 0) °C (>0 to 100) °C (>100 to 140) °C (>140 to 190) °C (>190 to 250) °C (>250 to 538) °C 0.38 °C 0.27 °C 0.27 °C 2.6 °C 2.6 °C 2.7 °C Fluke 52 II Type K Probe, Kaye Valprobe RT V. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Time3 – Measure (0 to 7200) sec 0.084 sec Stopwatch
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 9 of 14 SATELLITE FACILITY THE SCALE PEOPLE, INC., DBA THE LAB PEOPLE INC. 708-H Gum Rock Court Newport News, Virginia 23606 Amanda Beard Phone: 410 309 5880 I. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Distance3 – Measure Up to 6 in 0.002 in Height gauge or ruler II. Mechanical Parameter/Equipment Range CMC2 (±) Comments Analytical Balances3 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 700 mg 1 g 2 g 2.1 g 3 g 5 g 6 g 7 g 10 g 30 g 50 g 100 g 0.0073 mg 0.0073 mg 0.0073 mg 0.0095 mg 0.012 mg 0.012 mg 0.012 mg 0.012 mg 0.012 mg 0.017 mg 0.039 mg 0.043 mg 0.043 mg 0.043 mg 0.040 mg 0.043 mg 0.056 mg 0.058 mg 0.093 mg 0.14 mg 0.29 mg E2 weights & class 1 weights
to 6 in
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 10 of 14 Parameter/Equipment Range CMC2 (±) Comments Analytical Balances3 (cont) 150 g 200 g 230 g 250 g 400 g 500 g 0.32 mg 0.58 mg 0.61 mg 0.60 mg 1.3 mg 1.4 mg E2 weights & class 1 weights Top Loader Balances3 100 g 200 g 500 g 620 g 700 g 1000 g 1500 g 1700 g 2000 g 2500 g 3000 g 3200 g 4000 g 5000 g 6000 g 7500 g 10 000 g 12 000 g 16 000 g 20 000 g 25 000 g 30 000 g 34 000 g 35 000 g 40 000 g 50 000 g 60 000 g 64 kg 150 kg 300 kg 2.2 mg 2.4 mg 3.6 mg 3.6 mg 3.8 mg 6.3 mg 6.7 mg 7.0 mg 24 mg 24 mg 25 mg 0.11 g 27 mg 21 mg 21 mg 0.03 g 0.22 g 0.21 g 0.23 g 0.27 g 0.28 g 0.28 g 0.28 g 0.28 g 0.25 g 0.34 g 0.30 g 0.30 g 16 g 24 g Class 2, class E2 or class F weights
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 11 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Torque3– Measuring Equipment 1.78 lbf·in 10 lbf·in 100 lbf·in 200 lbf∙ft 0.0071 lbf·in 0.012 lbf·in 0.12 lbf·in 0.12 lbf∙ft Torque calibration system Force Measurement Equipment 3 – Tension & Compression 250 gf 2 lbf 10 lbf 25 lbf 50 lbf 100 lbf 200 lbf 500 lbf 1000 lbf 0.12 gf 0.0012 lbf 0.0025 lbf 0.011 lbf 0.023 lbf 0.045 lbf 0.11 lbf 0.23 lbf 0.45 lbf Standard weights Load cells or standard weights Scales3 1 lb 2 lb 5 lb 7 lb 10 lb 15 lb 20 lb 25 lb 50 lb 75 lb 100 lb 150 lb 200 lb 250 lb 500 lb 700 lb 1000 lb 1500 lb 2000 lb 2500 lb 5000 lb 7500 lb 10 000 lb 20 000 lb 50 000 lb 0.000 29 lb 0.000 50 lb 0.0013 lb 0.0011 lb 0.0033 lb 0.0033 lb 0.0050 lb 0.011 lb 0.012 lb 0.020 lb 0.023 lb 0.022 lb 0.042 lb 0.045 lb 0.13 lb 0.10 lb 0.25 lb 0.24 lb 0.50 lb 0.49 lb 1.3 lb 1.2 lb 2.5 lb 1.3 lb 11 lb Class F weights
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 12 of 14 Parameter/Equipment Range CMC2 (±) Comments Scales3 (cont) 10 kg 20 kg 25 kg 50 kg 60 kg 75 kg 80 kg 90 kg 100 kg 150 kg 200 kg 250 kg 270 kg 300 kg 400 kg 450 kg 500 kg 540 kg 600 kg 700 kg 720 kg 750 kg 800 kg 810 kg 900 kg 1000 kg 1250 kg 1350 kg 1500 kg 1700 kg 2000 kg 2500 kg 0.0022 kg 0.0031 kg 0.0036 kg 0.0051 kg 0.011 kg 0.011 kg 0.011 kg 0.011 kg 0.011 kg 0.021 kg 0.021 kg 0.021 kg 0.021 kg 0.042 kg 0.042 kg 0.042 kg 0.042 kg 0.042 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.10 kg 0.21 kg 0.21 kg 0.21 kg 0.21 kg 0.21 kg Class F weight Pipettes3 (0.1 to 1) µL (1 to 50) µL (50 to 100) µL (100 to 200) µL (200 to 500) µL (500 to 1250) µL (1250 to 2500) µL (2500 to 5000) µL (5000 to 12 500) µL (12 500 to 30 000) µL (30 000 to 50 000) µL (50 000 to 100 000) µL 0.032 µL 0.093 µL 0.29 µL 0.41 µL 0.45 µL 0.64 µL 1.2 µL 2.9 µL 4.9 µL 7.3 µL 8.4 µL 16 µL Gravimetric method
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 13 of 14 Parameter/Equipment Range CMC2 (±) Comments Load Cell Tension Compression (250 to 1500) lbf (>1500 to 5000) lbf (>5000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf (250 to 1500) lbf (>1500 to 5000) lbf (>5000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf 6.9 lbf 15 lbf 37 lbf 83 lbf 140 lbf 6.9 lbf 14 lbf 37 lbf 83 lbf 140 lbf Load cell Load cell Mass, Fixed Points 226.796 g (8 oz) 453.592 g (1 lb) 907.185 g (2 lb) 2267.962 g (5 lb) 4535.924 g (10 lb) 9071.85 g (20 lb) 11 339.809 g (25 lb) 22 679.619 g (50 lb) 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 25 kg 0.22 mg 0.26 mg 0.37 mg 1.0 mg 1.7 mg 100 mg 32 mg 62 mg 0.0023 mg 0.0023 mg 0.0023 mg 0.0024 mg 0.0023 mg 0.011 mg 0.0029 mg 0.0029 mg 0.0029 mg 0.0045 mg 0.0045 mg 0.0061 mg 0.013 mg 0.016 mg 0.023 mg 0.047 mg 0.22 mg 0.27 mg 0.38 mg 0.68 mg 2.8 mg 3.9 mg 9.9 mg 10 mg Modified substitution
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1452.01) Revised 01/09/2025 Page 14 of 14 II. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Time3 – Measure (0 to 7200) sec 0.084 sec Stopwatch _______________________________________ 1 This laboratory offers commercial calibration and field calibration services performed at the main laboratory listed above, and the following satellite laboratory listed below. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
0 to 7200 sec
15ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

9693-C Gerwig Lane, Columbia, MD, 21046, US

39.19384, -76.86461

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.