Poland
LabStar Mateusz Olejnik
ul. Os. Zachód A8/U13, 73-110, Stargard, Poland
PCA|AB 1651ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Register record
- PCACollected
- AB 1651Active
Certificates and scope
1PCA
ISO/IEC 17025
ActiveAB 1651
Accredited scope, certificate AB 1651
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | PN-EN ISO 15923-1:2025-02; PN-EN ISO 5667-13:2011; PN-EN 12176:2004; PN-EN 12880:2004; PN-EN 12879:2004; PN-EN 13342:2002; PB-22 ed. 1 z dn. 02.01.2018 r.; PB-26 ed. 1 z dn. 02.01.2018 r.; PN-ISO 10381-4:2007; PN-EN ISO 10390:2022-09; PN-ISO 11047:2001; PB-25 ed.2 z 09.04.2018 r.; PB-05 ed. 6 z dn. 15.04.2019 r. | Drinking water | 0.02 to 5 mg/l |
| chemical | PN-EN ISO 9963-1:2001+ Ap1:2004; PN-EN 26777:1999; PN-ISO 9297:1994; PB-06 ed. 3 z dn. 30.03.2017 r.; PN-ISO 5664:2002; PN-ISO 6439:1994; PN-EN ISO 15586:2005; PN-ISO 8288:2002 metoda A; PB-23 ed. 1 z dn. 02.01.2018 r.; PB-25 ed.2 z 09.04.2018 r. | Drinking water | 0.0005 to 10000 mg/l |
| chemical | PN-ISO 15705:2005; PN-EN ISO 5815-1:2019-12; PN-EN 872:2007+ Ap1:2007; PB-05 ed. 6 z dn. 15.04.2019 r.; PB-02 ed. 5 z dn. 15.04.2019 r.; PN-ISO 5667-10:2021-11; PN-77/C-04584; PB-15 ed. 2 z dn. 30.03.2017 r.; PN-EN 1899-2:2002; ISO 15923-2:2017 | Drinking water | 0.01 to 10000 mg/l O2; ºC |
| chemical | PN-EN ISO 15923-1:2025-02; PN-ISO 5667-5:2017-10; I-01/PO-15 ed.2 z dn. 06.04.2018 r.; PN-77/C-04584; PN-EN ISO 19458:2007; PB-09 ed. 2 z dn. 31.01.2017 r.; PB-08 ed. 3 z dn. 30.03.2017 r.; PN- EN ISO 10523:2012; PN-82/C-04576/08; PN-EN ISO 7027-1:2016-09; PB-16 ed. 2 z dn. 08.05.2017 r.; PN-EN ISO 8467:2001 | Drinking water | 0.01 to 1000 mg/l; ºC; mV; NTU; O2 |
| chemical | PN-ISO 5667-6:2016-12; PN-EN ISO 7887:2012; PN-EN 27888:1999; PN-C-04576-4:1994; PN-ISO 6332:2001+Ap:2016-06; PN-ISO 6059:1999; PB-03 ed. 3 z dn. 30.03.2017 r.; PB-24 ed.1 z dn. 02.01.2018 r.; PB-17 ed.1 z dn. 30.03.2017 r.; PN-EN ISO 7980:2002; PN-ISO 9964-3:1994; PN-EN ISO 15586:2005 | Drinking water | 0.05 to 12800 μS/cm |
| chemical | PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN ISO 19458:2007; PN-EN ISO 9308-2:2014-06; PB-12 ed.2 z dn. 11.05.2018 r.; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PB-01 ed. 2 z dn. 31.01.2017 r.; ISO-TS 15923-2:2017; PN-EN ISO 16266-2:2022-04; PN-EN ISO 11731:2017-08 +AP1:2019-12 | Drinking water | 1 to 50 ºC; mg/l; mmol/l; μg/l |
| chemical | - | Water | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Poland
- "EKO-SERWIS" s.c. Dorota Markowska, Maciej MarkowskiŁódź · ~347 kmPCAShares 4 accredited methods and materialsEN ISO 5667-13:2011ISO 5667-5:2017-10Drinking water
- SGS Polska Sp. z o.o.Pszczyna · ~461 kmPCAShares 4 accredited methods and materialsEN ISO 5667-13:2011ISO 15705:2005ISO 5667-5:2017-10
- EKOLAB Sp. z o.o.Kobylnica · ~178 kmPCAShares 3 accredited methods and materialsISO 15705:2005ISO 5667-5:2017-10Drinking water
- ORLEN Laboratorium S.A.Gdańsk · ~275 kmPCAShares 3 accredited methods and materialsISO 15705:2005ISO 5667-5:2017-10Drinking water
- EcoCentrum Elżbieta WolnyWrocław · ~279 kmPCAShares 3 accredited methods and materialsEN ISO 5667-13:2011ISO 5667-5:2017-10Drinking water
Accreditation data collected from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.