TAUW b.v.
Handelskade 37, 7417 DE, DEVENTER, Netherlands
- Accredited standards
- 15
- RvA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the RvA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 15 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
EN8
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
ISO5
ISO 9096Stationary source emissions - Manual determination of mass concentration of particulate matter
ISO 11338-1Stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - Part 1: Sampling
ISO 15713Stationary source emissions - Sampling and determination of gaseous fluoride content
ISO 21258Stationary source emissions - Determination of the mass concentration of dinitrogen monoxide (N2O) - Reference method: Non-dispersive infrared method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards2
EPA 316
NEN 2826
EN ISO/IEC 17025:2017; NEN-EN 14791; NEN-EN 1911; HF: NEN-ISO 15713; NH3: NEN 2826; NEN-EN-ISO 21877; CH2O: EPA 316 / NVN-CEN/TS 17638; NEN-EN 13211; NEN-EN 14385; NPR-CEN/TS 13649; NEN-EN 1948-1; NEN-ISO 11338-1
EN ISO/IEC 17025:2017; NEN-EN 12619; NEN-EN-ISO 21258; NEN-EN 13284-1; NEN-ISO 9096
NEN-EN 14181
Read from the RvA scope document we downloaded on 2026-02-12. Register refreshed 2026-11-08.
Scope as published by RvA
4 lines
ISO/IEC 17025
ActiveL429
The scope document we hold says it is valid until 2028-11-01.
Accredited scope, certificate L429
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NEN-EN 14181 | - | - |
| 2 | EN ISO/IEC 17025:2017; NEN-EN 14791; NEN-EN 1911; HF: NEN-ISO 15713; NH3: NEN 2826; NEN-EN-ISO 21877; CH2O: EPA 316 / NVN-CEN/TS 17638; NEN-EN 13211; NEN-EN 14385; NPR-CEN/TS 13649; NEN-EN 1948-1; NEN-ISO 11338-1 | Emitted air | - |
| 3 | NTA 9065: 2012 | Lucht en (proces)gassen | - |
| 4 | EN ISO/IEC 17025:2017; NEN-EN 12619; NEN-EN-ISO 21258; NEN-EN 13284-1; NEN-ISO 9096 | Emitted air | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Netherlands
Accreditation data refreshed from the RvA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.