Radiometrics Midwest Corporation
12 Devonwood Avenue, 60446-1349, Romeoville, IL, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Radiometrics Midwest Corporation?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 1495.01Active
Certificates and scope
1ISO/IEC 17025
Active1495.01
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1495.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | CFR 47, FCC Part 15B; CFR 47, FCC Part 18; ICES-003, Issue 7; IEC CISPR 11:2015; IEC CISPR 22:2008; IEC CISPR 32:2015; EN 55011:2016; EN 55032:2015; MIL-STD 461E:1999; MIL-STD 461F:2007; MIL-STD 461G:2015; RTCA/DO-160E:2004; RTCA/DO-160F:2007; RTCA/DO-160G:2010; VCCI CISPR 32 (2016); CFR 47, FCC Part 15C; CFR 47, FCC Parts 22, 24, 25, 27, 90, 95, 97 & 101; CFR 47, FCC Parts 20 & 90.219; ANSI C63.10-2020+Cor. 1-2023 +C63.10a-2024 +Errata to C63.10a-2024; RSS-GEN: Issue 5; RSS-119: Issue 12; RSS-130: Issue 2; RSS-131: Issue 3; RSS-210: Issue 11; RSS-247: Issue 4; ETSI EN 300 330 V2.1.1; ETSI EN 300 220-1 V3.1.1; ETSI EN 300 440 V2.2.1; ETSI EN 300 328 V2.2.2; ISO/IEC 17025:2017 | - | - |
| 2 | electrical | CFR 47, FCC Part 15C (using ANSI C63.10-2013); CFR 47, FCC Part 18 (using FCC MP-5:1986); MIL-STD 461E:1999; MIL-STD 461F:2007; MIL-STD 461G:2015; IEC 61000-4-2:2008; RTCA/DO-160E:2004; RTCA/DO-160F:2007; RTCA/DO-160G:2010; ISO 10605; ISO 10605:2001; IEC 61000-4-3:2020; IEC 61000-4-8:2009; IEC 61000-4-6:2013; ISO 11452-4:2011; IEC 61000-4-11:2020; IEC 61000-4-4:2012; IEC 61000-4-5:2005; IEC 61000-4-5:2014 | - | 30 to 400 Hz; MHz; kHz; GHz |
| 3 | electrical | RTCA/DO-160E:2004; RTCA/DO-160F:2007; RTCA/DO-160G:2010; ISO 11451-2:2005; ISO 11451-2:2015; CISPR 12:2007; CISPR 25:2016; CISPR 25:2021; ISO 11452-2:2019; SAE J1113-11:2018; ISO 7637-2:2011; IEC 61726:2015; IEEE Std 299:2006; ANSI C12.1:2014; EN 61000-3-2:2014; EN 61000-3-3:2013; ISO 13766-1:2018; ISO 13766-2:2018; ISO 14982:2009; ISO 7176-21:2009; EN 12184:2009; EN 55035:2017; IEC 60601-1-2:2014; EN 61000-6-1:2019; EN 61000-6-2:2019; EN 61000-6-3:2021; EN 61000-6-4:2019; EN 61326-1:2020; RESNA WC-2:2009; ETSI EN 301 489-1 V2.2.3; ETSI EN 301 489-3 V2.1.1; ETSI EN 301 489-17 V3.2.4; ETSI EN 300 220-2 V3.2.1 | - | - |
| 4 | electrical | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; ANSI/TIA-603-E; ANSI C63.26:2015 | - | to 26000 MHz |
| 5 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- HCT AmericaMilpitas, CA · ~2,918 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ISO 10605
- Elite Electronic EngineeringDowners Grove, IL · ~18 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Motorola Solutions, Inc., SchaumburgSchaumburg, IL · ~43 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- UL LLCNorthbrook, IL · ~58 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- APTIV WESTFIELD TESTWestfield, IN · ~243 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.