Registers refreshed 2026-11-20.See refresh dates
Canada

JEM Precision

Edmonton, Canada

Visit website
A2LA 1500.04ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 1500.04 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 2 of 16 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Height Gauges3, 8 Up to 40 in 300 µin Gauge blocks Indicators3, 8 Up to 2 in 96 µin Indicator calibrator Indicator Calibrators Up to 2 in 79 µin Gauge blocks, precision height gauge Length Standards Up to 12 in (12 to 24) in (20 to 80) in (73 + 0.64L) µin (61 + 1.6L) µin (-160 + 11L) µin Gauge blocks, precision height gauge, Laser interferometer Precision Levels Sensitivity8 Up to 0.0005 in/ft 17 % Parallel bars, gauge blocks Linear Dimension & Angle – X-Axis Y-Axis Angle 8 in 4 in (0 to 360)° 200 µin 250 µin 0.07° Optical comparator Micrometers3, 8 – Depth, ID, OD Up to 6 in (6 to 24) in (31 + 1.2L) µin (8 + 4.6L) µin Gauge blocks Optical Comparators3, 8 X-Axis Y-Axis Angle 8 in 4 in (0 to 360)° 81 µin 100 µin 0.052° Gauge blocks Angle blocks Protractors8 (0 to 45)° (45 to 90)° 0.0005° + 0.0006 % 0.0012° Sine bar, gauge blocks, master square, surface plate
3-Sine Bars; Squares; Step Gauges; Surface Plates; Tape Measures; Rulers; Thickness Gauges; Straight Edges
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 3 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Sine Bars – Parallelism Length Angle (20 in Bar Length) (5 to 20) in (5 to 20) in Up to 45° 110 µin (70 + 3.5L) µin 19″ Surface plate, precision height gauge Surface plate, precision height gauge, gauge blocks Squares8 Up to 24 in 26 µin/in Master square, gauge blocks Step Gauges8 Up to 1 in (1 to 6) in 68 µin (64 + 2L) µin Gauge blocks, precision height gauge Surface Plates3 – Flatness Repeatability Up to 12 ft x 12 ft Up to 12 ft x 12 ft (24 + 0.06L) µin 24 µin Laser interferometer Repeat-o-meter Tape Measures8 Up to 40 in (> 40 to 120) in (> 120 to 280) in (> 280 to 440) in (2200 + 13L) µin (1600 + 28L) µin (2900 + 16L) µin (3900 + 12L) µin Tape measure calibrator Rulers8 Up to 40 in (> 40 to 72) in (2200 + 13L) µin (1600 + 28L) µin Tape measure calibrator Thickness Gauges3 Up to 1 in (150 + 1400L) µin Gauge blocks Straight Edges – Parallelism Straightness Up to 72 in Up to 72 in (60 + 12L) µin (50 + 8.5L) µin Surface plate, precision height gauge
-
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 4 of 16 II. Mechanical Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Force – Measure & Measuring Equipment3, 8 (0 to 500) lbs 0.03 % Dead weight Hydraulic Pressure/Vacuum – Measure & Measuring Equipment3 (-14.2 to 0) psig (0 to 6) psig (6 to 15 000) psig 0.036 psi 0.006 psi 0.10 % Digital pressure gauges & pumps Pneumatic Pressure Measure & Measuring Equipment3 (-13.2 to 0) psig (0 to 30) psig (30 to 100) psig (100 to 900) psig (900 to 3000) psig 0.059 psi 0.015 psi 0.04 % + 0.0074 psi 0.40 psi 0.04 % + 0.19 psi HPC50 w/ 100 psi module HPC50 w/ 3000 psi module Load Cells Compression Up to 1000 lbf (> 1000 to 25 000) lbf (> 25 000 to 60 000) lbf 0.33 + (0.0011·lbf) 0.10 + (0.000 88·lbf) 2.3 + (0.0007·lbf) Load cells Scales & Balances3, 5 Up to 1 g (1 to 1000) g (> 1 to 15.6) kg Up to 1075 lbs 0.005 mg 0.000 27 % 0.38 % M + 26 mg 0.012 % Precision weights Field weights Aircraft Scales Up to 25 000 lb (> 25 000 to 60 000) lb 3 lb + 0.000 44·lbf 7.2 lb + 0.0006·lbf Load cells Torque Transducers8 (0 to 1) lb∙ft (1 to 8) lb∙ft (8 to 250) lb∙ft (250 to 1500) lb∙ft 0.06 % 0.2 % 0.2 % 0.02 % Torque calibration arm; ASTM 6 Class weights Torque Wrenches & Drivers (0.053 to 0.52) lb∙ft (0.42 to 3.33) lb∙ft (0.84 to 8.33) lb∙ft (4.2 to 41) lb∙ft (25 to 250) lb.ft (50 to 1000) lb∙ft 0.7 % 0.6 % 0.4 % 0.4 % 0.6 % 0.2 % Torque system & transducers
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 5 of 16 III. Thermodynamics Parameter/Equipment Range CMC2, 4, 7 (±) Comments IR Thermometer (35 to 500) °C 0.25 °C + 0.0019T Fluke 4181 Blackbody Ɛ = 0.95 λ = (8 to 14) μm; referenced @ 23 °C ambient Temperature – Measuring Equipment (-20 to 100) °C 0 °C (100 to 400) °C 0.080 °C 0.0050 °C 0.040 °C Calibration bath, PRT, & thermometer ASTM E56 ice point Dry well, PRT, & thermometer
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 6 of 16 SATELLITE 1103 Parsons Rd SW, Edmonton, Alberta T6E 0B2 CANADA Bhisam Prasad Phone: 780 440 1933 I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 11 (±) Comments DC Voltage3 – Measure (0 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (120 to 1000) V (0 to 10) kV (10 to 140) kV 11 µV/V + 0.35 µV 9.6 µV/V + 0.34 µV 9.6 µV/V + 0.57 µV 12 µV/V + 35 µV (12 + (14V/1000)2) µV/V + 120 µV 0.034 % + 0.034 V 0.091 % + 0.8 V Agilent 3458A V = voltage Vitrek 4700 w/ HVL-150 probe DC Voltage3 – Generate (0 to 329.9999) mV (0.33 to 3.299 999) V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1000.000) V 16 µV/V + 0.78 µV 8.6 µV/V + 1.6 µV 9.4 µV/V + 16 µV 14 µV/V + 120 µV 14 µV/V + 1200 µV Fluke 552X series calibrator DC Current3 – Measure (12 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.05) A 24 µA/A + 0.93 nA 24 µA/A + 5.8 nA 24 µA/A + 58 nA 41 µA/A + 0.58 µA 0.013 % + 12 µA Agilent 3458A Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 18 µΩ/Ω + 58 µΩ 15 µΩ/Ω + 0.58 mΩ 13 µΩ/Ω + 0.57 mΩ 13 µΩ/Ω + 5.7 mΩ 13 µΩ/Ω + 56 mΩ 18 µΩ/Ω + 2.3 Ω 58 µΩ/Ω + 120 Ω 0.058 % + 1200 Ω 0.58 % + 12 kΩ Agilent 3458A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 7 of 16 Parameter/Equipment Range CMC2, 11 (±) Comments DC Current3 – Generate Clamp-On Meters (0 to 329.999) µA (0.330 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (20 to 149.999) A (150 to 549.999) A (550 to 1025) A 0.012 % + 0.016 µA 78 µA/A + 0.039 µA 78 µA/A + 0.20 µA 78 µA/A + 2.0 µA 0.016 % + 32 µA 0.03 % + 32 µA 0.039 % + 390 µA 0.078 % + 580 µA 0.58 % + 0.17 A 0.58 % + 0.58 A 0.59 % + 0.58 A Fluke 552X series calibrator Fluke 552X series w/ Fluke 5500A/coil Resistance3 – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 32 µΩ/Ω + 0.78 mΩ 24 µΩ/Ω + 1.2 mΩ 22 µΩ/Ω + 1.1 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 0.16 Ω 22 µΩ/Ω + 0.16 Ω 25 µΩ/Ω + 1.6 Ω 25 µΩ/Ω + 1.6 Ω 47 µΩ/Ω + 24 Ω 0.011 % + 36 Ω 0.02 % + 2.0 kΩ 0.039 % + 2.4 kΩ 0.24 % + 78 kΩ 1.2 % + 390 kΩ Fluke 552X series calibrator Parameter/Range Frequency CMC2, 11 (±) Comments AC Voltage3 – Measure (1 to 10) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.035 % + 3.5 µV 0.024 % + 1.3 µV 0.035 % + 1.3 µV 0.12 % + 1.3 µV 0.58 % + 1.3 µV 4.7 % + 2.4 µV Agilent 3458A
8-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 8 of 16 Parameter/Range Frequency CMC2, 11 (±) Comments AC Voltage3 – Measure (cont) (10 to 100) mV (0.1 to 1.0) V (1.0 to 10.0) V (10.0 to 100.0) V (100.0 to 700) V (0.1 to 10) kV (10 to 100) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 60 Hz 0.0081 % + 4.7 µV 0.0081 % + 2.4 µV 0.017 % + 2.4 µV 0.035 % + 2.4 µV 0.093 % + 2.4 µV 0.35 % + 12 µV 1.2 % + 12 µV 1.8 % + 12 µV 0.0081 % + 47 µV 0.0081 % + 24 µV 0.017 % + 24 µV 0.035 % + 24 µV 0.093 % + 24 µV 0.35 % + 120 µV 1.2 % + 120 µV 1.8 % + 120 µV 0.0081 % + 0.47 mV 0.0081 % + 0.24 mV 0.017 % + 0.24 mV 0.035 % + 0.24 mV 0.093 % + 0.24 mV 0.35 % + 1.2 mV 1.2 % + 1.2 mV 1.8 % + 1.2 mV 0.024 % + 4.7 mV 0.024 % + 2.4 mV 0.024 % + 2.4 mV 0.041 % + 2.4 mV 0.14 % + 2.4 mV 0.47 % + 12 mV 1.8 % + 12 mV 0.047 % + 47 mV 0.047 % + 24 mV 0.07 % + 24 mV 0.14 % + 24 mV 0.35 % + 24 mV 0.14 % + 0.11 V 0.57 % + 1.1 V Agilent 3458A Vitrek 4700 w/ HVL probe
See scope document
9-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 9 of 16 Parameter/Range Frequency CMC2, 11 (±) Comments AC Voltage3 – Generate (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.063 % + 4.7 µV 0.012 % + 4.7 µV 0.016 % + 4.7 µV 0.078 % + 4.7 µV 0.28 % + 9.4 µV 0.63 % + 39 µV 0.024 % + 6.3 µV 0.012 % + 6.3 µV 0.013 % + 6.3 µV 0.028 % + 6.3 µV 0.063 % + 25 µV 0.16 % + 55 µV 0.024 % + 39 µV 0.012 % + 47 µV 0.015 % + 47 µV 0.024 % + 39 µV 0.055 % + 97 µV 0.19 % + 470 µV 0.024 % + 510 µV 0.012 % + 470 µV 0.019 % + 470 µV 0.028 % + 470 µV 0.07 % + 1300 µV 0.015 % + 1600 µV 0.016 % + 4700 µV 0.02 % + 4700 µV 0.024 % + 4700 µV 0.16 % + 39 000 µV 0.024 % + 7800 µV 0.02 % + 7800 µV 0.024 % + 7800 µV Fluke 552X series calibrator
See scope document
10-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 10 of 16 Parameter/Range Frequency CMC2, 11 (±) Comments AC Current3 – Measure (5 to 100) µA (0.05 to 1) mA (0.5 to 10) mA (5 to 100) mA (0.05 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz 0.47 % + 0.035 µA 0.18 % + 0.035 µA 0.07 % + 0.035 µA 0.07 % + 0.035 µA 0.47 % + 0.24 µA 0.18 % + 0.24 µA 0.07 % + 0.24 µA 0.035 % + 0.24 µA 0.47 % + 2.4 µA 0.18 % + 2.4 µA 0.07 % + 2.4 µA 0.035 % + 2.4 µA 0.47 % + 24 µA 0.18 % + 24 µA 0.07 % + 24 µA 0.035 % + 24 µA 0.47 % + 240 µA 0.19 % + 240 µA 0.093 % + 240 µA 0.12 % + 240 µA Agilent 3458A AC Current3 – Generate (29 to 329.99) µA (0.33 to 3.2999) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 0.078 µA 0.12 % + 0.078 µA 0.097 % + 0.078 µA 0.24 % + 0.12 µA 0.63 % + 0.16 µA 1.3 % + 0.32 µA 0.16 % + 0.12 µA 0.097 % + 0.12 µA 0.078 % + 0.12 µA 0.16 % + 0.16 µA 0.39 % + 0.24 µA 0.78 % + 0.47 µA Fluke 552X series calibrator
5 to 100 µA
11-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 11 of 16 Parameter/Range Frequency CMC2, 11 (±) Comments AC Current3 – Generate (cont) (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A Clamp-On Meters: (Toroidal Type) (20 to 54.999) A (55 to 149.999) A (150 to 1025) A (20 to 54.999) A (55 to 149.999) A (150 to 400) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz 0.14 % + 1.6 µA 0.07 % + 1.6 µA 0.032 % + 1.6 µA 0.063 % + 1.6 µA 0.16 % + 2.4 µA 0.32 % + 3.2 µA 0.14 % + 16 µA 0.070 % + 16 µA 0.032 % + 16 µA 0.078 % + 39 µA 0.16 % + 78 µA 0.32 % + 160 µA 0.14 % + 78 µA 0.039 % + 78 µA 0.47 % + 780 µA 2.0 % + 3900 µA 0.14 % + 78 µA 0.047 % + 78 µA 0.47 % + 780 µA 2.0 % + 3900 µA 0.047 % + 1600 µA 0.078 % + 1600 µA 2.4 % + 1600 µA 0.094 % + 3900 µA 0.12 % + 3900 µA 2.4 % + 3900 µA 0.31 % + 0.054 A 0.34 % + 0.042 A 0.34 % + 0.13 A 0.93 % + 0.054 A 0.94 % + 0.046 A 1.2 % + 0.22 A Fluke 552X series calibrator Fluke 552X series w/ Fluke 5500A/coil
See scope document
12-AC Current; Capacitance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 12 of 16 Parameter/Range Frequency CMC2, 11 (±) Comments AC Current3 – Generate (cont) Clamp-On Meters: (Non-Toroidal Type) (20 to 149.999) A (150 to 549.999) A (550 to 1025) A (20 to 149.999) A (150 to 400) A (45 to 65) Hz (65 to 440) Hz 0.65 % + 0.30 A 0.66 % + 1.1 A 0.65 % + 1.1 A 1.2 % + 0.30 A 1.4 % + 1.1 A Fluke 552X series w/ Fluke 5500A/coil Capacitance3 – Generate (0.22 to 0.399 99) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.39 % + 0.0078 nF 0.39 % + 0.0078 nF 0.39 % + 0.0078 nF 0.20 % + 0.0078 nF 0.20 % + 0.078 nF 0.20 % + 0.078 nF 0.20 % + 0.24 nF 0.20 % + 0.78 nF 0.20 % + 2.4 nF 0.20 % + 7.8 nF 0.32 % + 24 nF 0.35 % + 78 nF 0.35 % + 240 nF 0.35 % + 0.78 µF 0.35 % + 2.4 µF 0.35 % + 7.8 µF 0.59 % + 24 µF 0.86 % + 78 µF Fluke 552X series calibrator
See scope document
13-thermocouples; thermocouple indicating devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 13 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicating Devices3 – Type B Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.35 °C 0.27 °C 0.24 °C 0.26 °C 0.39 °C 0.13 °C 0.11 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.11 °C 0.14 °C 0.18 °C 0.26 °C 0.14 °C 0.13 °C 0.21 °C 0.32 °C 0.32 °C 0.18 °C 0.15 °C 0.14 °C 0.21 °C 0.45 °C 0.28 °C 0.26 °C 0.32 °C 0.37 °C 0.28 °C 0.29 °C 0.36 °C 0.49 °C 0.19 °C 0.13 °C 0.11 °C Fluke 552X series calibrator
See scope document
14-RTD Indicators & Indicating Systems; Oscilloscopes
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 14 of 16 Parameter/Equipment Range CMC2, 6, 11 (±) Comments Electrical Simulation of RTD Indicators & Indicating Systems3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.039 °C 0.039 °C 0.055 °C 0.07 °C 0.078 °C 0.094 °C 0.18 °C Fluke 552X series calibrator Oscilloscopes3 – Amplitude – DC Signal 50 Ω Load 1 MΩ Load Amplitude – Square Wave 50 Ω Load 1 MΩ Load Bandwidth Flatness Time Marker Resistance – Measure 1 mV to 6.6 V 1 mV to 130 V 1 mV to 6.6 Vpp 10 Hz to 100 kHz 1 mV to 130 Vpp 10 Hz to 100 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 ms to 5 s 2 ns to 20 ms (40 to 60) Ω (0.5 to 1.5) MΩ 0.20 % + 32 µV 0.039 % + 32 µV 0.20 % + 32 µV 0.078 % + 32 µV 1.2 % + 78 µV 1.6 % + 78 µV 3.2 % + 78 µV 3.9 % + 78 µV (20 + (t1000)) µs/s 1.9 µs/s 0.079 % 0.078 % Fluke 552XA/SC1100 t = time in seconds
-
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 15 of 16 Parameter/Equipment Range CMC2 (±) Comments Insulation Testers Up to 35 kV 50 kΩ 100 kΩ 200 kΩ 250 kΩ 500 kΩ 1 MΩ 2.5 MΩ 5 MΩ 10 MΩ 30 MΩ 40 MΩ 50 MΩ 100 MΩ 200 MΩ 400 MΩ 1 GΩ 1.9 GΩ 9 GΩ 0.032 kΩ 0.064 kΩ 0.13 kΩ 0.16 kΩ 0.32 kΩ 0.00064 MΩ 0.0016 MΩ 0.0032 MΩ 0.0064 MΩ 0.019 MΩ 0.026 MΩ 0.032 MΩ 0.064 MΩ 0.13 MΩ 0.32 MΩ 0.00071 GΩ 0.0013 GΩ 0.023 GΩ Standard resistors II. Time & Frequency Parameter/Equipment Range CMC2, 6, 7 (±) Comments Frequency3 – Measure (1 to 40) Hz 40 Hz to 10 MHz 0.058 % 0.012 % Agilent 3458A Frequency3 – Measuring Equipment 0.01 Hz to 2 MHz 50 kHz to 1100 MHZ 2 μHz/Hz + 3.9 μHz 2 μHz/Hz Fluke 552XA Fluke 552XA/SC1100 _______________________________ 1 This laboratory offers commercial calibration services and field calibration service, where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1500.04) Revised 04/08/2026 Page 16 of 16 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. D is the numerical value of the nominal diameter of the device (Diameter, External and Internal); or the long diagonal (Surface Plates - Flatness) measured in inches. M is the numerical value of the nominal weight measured in Kg (Mass, Scales). T is the numerical value of the nominal torque in foot pounds. T is the numerical value of nominal temperature measured in degrees Celsius. 5 The contributions from the “best existing device” are not included in the CMC claim. 6 In the statement of CMC, percentages are to be read as percent of reading, unless otherwise noted. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 The contributions attributed to the repeatability of the “best existing device” are not included in the CMC claim. 9 The contributions attributed to the emissivity of the infrared calibrator are not included in the CMC claim. 10 This scope meets A2LA’s P112 Flexible Scope Policy. 11 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
17ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .