FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Germany

SGS Analytics Germany

Gubener Straße 39, 86156, Augsburg, Germany

DAKKS|D-PL-14004-01-05ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
9
Standards
8
Locations
2
One of 2 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at SGS Analytics Germany?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-14004-01-05Active

Accredited standards

8

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN 13060Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; ISO 15883-1; ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; EN ISO 15883-1

As written on the certificate · Line 6 (DAKKS D-PL-14004-01-05)

DIN EN ISO 13485: 2016 3; DIN EN ISO 14161 : 2010 -03; DIN EN ISO 15883 -1 : 2014 -10 Reinigungs -Desinfektionsgeräte - Teil 1; DIN EN ISO 15883 -2 : 2009 -09 Reinigungs -Desinfektionsgeräte - Teil 2; DIN EN 13060 : 2019 -02

ISO 14161Sterilization of health care products - Biological indicators - Guidance for the selection, use and interpretation of results
As written on the certificate · Line 5 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; ISO 15883-1; ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; EN ISO 15883-1

As written on the certificate · Line 6 (DAKKS D-PL-14004-01-05)

DIN EN ISO 13485: 2016 3; DIN EN ISO 14161 : 2010 -03; DIN EN ISO 15883 -1 : 2014 -10 Reinigungs -Desinfektionsgeräte - Teil 1; DIN EN ISO 15883 -2 : 2009 -09 Reinigungs -Desinfektionsgeräte - Teil 2; DIN EN 13060 : 2019 -02

ISO 15883-1Washer-disinfectors - Part 1: General requirements, terms and definitions and tests
As written on the certificate · Line 4 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883 -2; DIN EN ISO 15883-4; DIN EN ISO 15883-6; ISO 15883-1

As written on the certificate · Line 5 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; ISO 15883-1; ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; EN ISO 15883-1

As written on the certificate · Line 6 (DAKKS D-PL-14004-01-05)

DIN EN ISO 13485: 2016 3; DIN EN ISO 14161 : 2010 -03; DIN EN ISO 15883 -1 : 2014 -10 Reinigungs -Desinfektionsgeräte - Teil 1; DIN EN ISO 15883 -2 : 2009 -09 Reinigungs -Desinfektionsgeräte - Teil 2; DIN EN 13060 : 2019 -02

ISO 15883-2Washer-disinfectors - Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for critical and semi-critical medical devices
As written on the certificate · Line 4 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883 -2; DIN EN ISO 15883-4; DIN EN ISO 15883-6; ISO 15883-1

As written on the certificate · Line 6 (DAKKS D-PL-14004-01-05)

DIN EN ISO 13485: 2016 3; DIN EN ISO 14161 : 2010 -03; DIN EN ISO 15883 -1 : 2014 -10 Reinigungs -Desinfektionsgeräte - Teil 1; DIN EN ISO 15883 -2 : 2009 -09 Reinigungs -Desinfektionsgeräte - Teil 2; DIN EN 13060 : 2019 -02

ISO 15883-4Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes
As written on the certificate · Line 4 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883 -2; DIN EN ISO 15883-4; DIN EN ISO 15883-6; ISO 15883-1

As written on the certificate · Line 7 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04; DIN EN ISO 15883 -7 : 2016 -10; DIN EN ISO 17665 -1 : 2006 -11 Sterilisation von Produkten für die Gesundheitsfürsorge - Feuchte Hitze - Teil 1; DIN 58949; ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04

ISO 15883-6Washer-disinfectors - Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection for non-critical medical devices and health care equipment
As written on the certificate · Line 4 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883 -2; DIN EN ISO 15883-4; DIN EN ISO 15883-6; ISO 15883-1

As written on the certificate · Line 7 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04; DIN EN ISO 15883 -7 : 2016 -10; DIN EN ISO 17665 -1 : 2006 -11 Sterilisation von Produkten für die Gesundheitsfürsorge - Feuchte Hitze - Teil 1; DIN 58949; ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04

ISO 15883-7Washer-disinfectors - Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-critical thermolabile medical devices and health care equipment
As written on the certificate · Line 5 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; ISO 15883-1; ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; EN ISO 15883-1

As written on the certificate · Line 7 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04; DIN EN ISO 15883 -7 : 2016 -10; DIN EN ISO 17665 -1 : 2006 -11 Sterilisation von Produkten für die Gesundheitsfürsorge - Feuchte Hitze - Teil 1; DIN 58949; ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04

ISO 17665-1Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
As written on the certificate · Line 5 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883-1; DIN EN ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; ISO 15883-1; ISO 15883-7 SOP-M-SAS-REG-PNHY LQ RDG Mitgeltend: DIN ISO/TS 15883-5 KRINKO/BfArM- Empfehlung Aufbereitung MP Sterilisationsverfahren Prüfungen im Rahmen der Validierung - mit feuchter Hitze Leistungsqualifikation DIN EN 13060 DIN EN ISO 17665-1 SOP-M-SAS-REG-PNHY LQ Dampfsterilisation Mitgeltend: DIN EN ISO 14161; EN ISO 15883-1

As written on the certificate · Line 7 (DAKKS D-PL-14004-01-05)

DIN EN ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04; DIN EN ISO 15883 -7 : 2016 -10; DIN EN ISO 17665 -1 : 2006 -11 Sterilisation von Produkten für die Gesundheitsfürsorge - Feuchte Hitze - Teil 1; DIN 58949; ISO 15883 -4 : 2019 -06 Re inigungs -Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope DIN ISO/TS 15883 -5 : 2006 -02 Reinigungs -Desinfektionsgeräte - Teil 5: Prüfanschmutzungen und - verfahren zum Nachweis der Reinigungswirkung DIN EN ISO 15883 -6 : 2016 -04

Scope as published by DAKKS

9 lines
DAKKS

ISO/IEC 17025

Active

D-PL-14004-01-05

View scope

Location

Gubener Straße 39, Augsburg, 86156, DE

48.38654, 10.86132

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.