X-Rite China Service Center
4/F, Buiding#10, IBP Phase 2, 518 North Fuquan Road, Shanghai, Changning District, 200335, People's Republic of China, Shanghai, Changning District, China
- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 2108.03 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.03) Revised 03/01/2026 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO 17025:2017
X-RITE CHINA SERVICE CENTER
4F, Building #10 IBP Phase 2, 518 North Fuquan Rd, Changning,
Shanghai, China, People’s Republic of China 200335
Phone: (021) 3279 6671
Kevin Irwin Phone: 616 803 2118
CALIBRATION
Valid To: March 31, 2026 Certificate Number: 2108.03
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations
1, 7:
I. Optical Quantities
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
Model 962, 964, 939
(0/45 Optical
Geometry)
Model CI60, CI61,
CI62, CI64, CI64
UV, CI4xxx
Model CI7xxx
3
Model 504, 508, 518,
528, 530 (0/45
Optical Geometry)
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
(360 to 400) nm
(410 to 750) nm
400 nm
(410 to 700) nm
1.7 % R
0.92 % R
0.95 % R
0.41 % R
0.83 % R
0.43 % R
1.7 % R
0.89 % R
White reflection
standards with:
SPP X-it 962
SPP CI6x
SPP CI7x
SPP X-it 500 | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.03) Revised 03/01/2026 Page 2 of 5
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model Exact
(0/45 Optical
Geometry)
Model eXact 2 (ETV)
(0/45 Optical
Geometry)
Model MA9X
(Aspecular Optical
Geometry)
-15 degree
15 degree
25 degree
45 degree
75 degree
110 degree
Model MA-x Series
and OEM Variants
(TOP
Spectrophotometer)
(Aspecular Optical
Geometry)
15 degree
25 degree
45 degree
75 degree
110 degree
(400 to 410) nm
(420 to 700) nm
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
1.8 % R
1.1 % R
1.8 % R
1.1 % R
0.96 % R
0.99 % R
0.91 % R
0.78 % R
0.86 % R
0.75 % R
0.81 % R
0.70 % R
0.88 % R
0.80 % R
0.95 % R
0.90 % R
1.2 % R
1.1 % R
1.2 % R
1.1 % R
1.1 % R
0.96 % R
1.2 % R
1.0 % R
1.2 % R
White reflection
standards with:
SPP exact
SPP ETV
SPP final 2
MA9x
Topaz service
manual | 400 to 700 nm |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.03) Revised 03/01/2026 Page 3 of 5
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model MA-x Series and
OEM variants (TOP II
Spectro-photometer)
(Aspecular Optical
Geometry)
-15 degree
15 degree
25 degree
45 degree
75 degree
110 degree
Model MA-Tx Series and
OEM Variants (KOH
Spectrophotometer)
(Aspecular Optical
Geometry)
-15 degree
15 degree
25 degree
45 degree
75 degree
110 degree
(400 to 700) nm
(400 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
1.6 % R
1.2 % R
1.1 % R
1.0 % R
1.1 % R
0.96 % R
1.1 % R
1.0 % R
1.2 % R
1.1 % R
1.0 % R
1.1 % R
0.85 % R
0.95 % R
0.80 % R
0.88 % R
0.73 % R
0.98 % R
0.78 % R
0.98 % R
0.92 % R
White reflection
standards with:
Topaz 2 Service
Manual
Kohinoor service
manual
Optical Radiation3
(Lightbooth)
2300 K (Horizon)
2856 K (Illuminate A)
20 K
22 K
X-Rite LightSpex
Pro radiometer | 400 to 700 nm |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.03) Revised 03/01/2026 Page 4 of 5
SATTELITE FACILITY
X-RITE GUANGZHOU SERVICE CENTER
Room 1006-1008, ChengQi Mansion, No 63 Nanan Road
Liwan District 510160, Guangdong P.R. China 510170
Telephone +86-20-8375-2900
CALIBRATION
I. Optical Quantities
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
Model Exact
(0/45 Optical
Geometry)
Model eXact (NGH)
(0/45 Optical
Geometry)
Model Ci5/Ci73
(Sphere 0/8° Optical
Geometry)
(400 to 410) nm
(420 to 700) nm
400 to 410) nm
(420 to 700) nm
(360 to 390) nm
(400 to 740) nm
1.8 % R
1.1 % R
1.8 % R
1.1 % R
0.88 % R
0.49 % R
White reflection
standards with:
SPP exact
SPP ETV
SPP CtestXP
Optical Radiation3
(Lightbooth)
2300 K (Horizon)
2856 K (Illuminate A)
20 K
22 K
X-Rite LightSpex Pro
radiometer
____________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | 400 to 740 nm |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.03) Revised 03/01/2026 Page 5 of 5
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, R is the reflectance.
5 The product families have the same optical geometries and calibration procedures. The features on the
display and outputs are the only differences.
6 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white
ceramic. Color calibration is mainly based on inter-instrument agreement.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.