Registers refreshed 2026-11-20.See refresh dates
Poland

Państwowa Akademia Nauk Stosowanych im. Ignacego Mościckiego

ul. Narutowicza 9, 06-400, Ciechanów, Poland

PCA AB 1877ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM G85
ISO 1519Paints and varnishes - Bend test (cylindrical mandrel)
ISO 2808Paints and varnishes - Determination of film thickness
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 11997-1Paints and varnishes - Determination of resistance to cyclic corrosion conditions - Part 1: Wet (salt fog)/dry/humid
VDA 621

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

2 lines
PCA

ISO/IEC 17025

Active

AB 1877

The scope document we hold says it is valid until 2027-10-02.

View on PCA

Accredited scope, certificate AB 1877

LineMethodMatrixRange
1-construction products and materials, paints and varnishes
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1877 Scope of accreditation No AB 1877 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 1877 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 3 z/of 13.02.2026 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ MECHANICZNYCH I FIZYCZNYCH MARIA SZAFRAN Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1877 z dnia 08.11.2023 r. Cykl akredytacji od 03.10.2023 r. do 02.10.2027 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1877 of 08.11.2023 Accreditation cycle from 03.10.2023 to 02.10.2027 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 3, 13.02.2026 1/3 Nazwa i adres / Name and address PAŃSTWOWA AKADEMIA NAUK STOSOWANYCH IM. IGNACEGO MOŚCICKIEGO LABORATORIUM BADAWCZE INŻYNIERII MECHANICZNEJ I MATERIAŁOWEJ ul. Narutowicza 9 06-400 Ciechanów Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - J/8, J/45 - N/8, N/45 - Badania mechaniczne wyrobów i materiałów konstrukcyjnych, farb i lakierów / Mechanical test of construction products and materials, paints and varnishes - Badania właściwości fiycznych wyrobów i materiałów konstrukcyjnych , farb i lakierów / Tests of physical properties of construction products and materials, paints and varnishes Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1877
-
2PN-EN ISO 9227:2023-03; DIN-EN ISO 9227:2023-03; ASTM G85-19; MBN 10494-6:2016-03; AA-0324: 2010; TL 244:2017-06; TL 260:2019-03; DBL 7381:2021-01; PN-EN ISO 11997-1:2017-10; VDA 621-415; AA-0224:2018; GS 90011:2023-04; DBL 7382:2020-12; PV 1209:2016-02; PV 1210:2004; PN-EN ISO 2808:2020-01; MBN 10494-1:2016-03; TL 262:2011-11; TL 216:2021-04; PN-EN ISO 1519:2012; MBN 10494-5:2016-03Metale i ich stopy, powłoki i pokrycia; Zestawy malarskie, powłoki40 to 200 μm

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Narutowicza 9, Ciechanów, 06-400, PL

52.87120, 20.60625

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.