Powiatowa Stacja Sanitarno-Epidemiologiczna w Starachowicach
ul. Złota 6, 27-200, Starachowice, Poland
- Accredited standards
- 25
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 25 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO17
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
Show all 17
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN3
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards5
C-04576-4:1994
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05
PN-EN ISO 5349-1:2004; PN-EN ISO 5349- 2:2004; PN-EN ISO 5349-2:2004 / A1:2015-11; PN-EN 14253+A1:2011
PN-EN 27888:1999; PN-C-04576-4:1994; PN-82/C-04576.08; PN-EN ISO 7027-1:2016-09; PN-ISO 6332:2001 + Ap1:2016-06; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012+ Ap1:2015-06; PN-EN ISO 8467:2001; PN-ISO 6059:1999; PN-92/C-04590/03; PN-ISO 5667-5:2017-10
PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12; PN-EN ISO 19458:2007
PN-EN ISO 7027-1:2016-09; PN-82/C-04576.08; PN-EN ISO 8467:2001; PN-EN ISO 10523:2012; PB/SBHŚ/03; PB/SBHŚ/04; PN-EN ISO 6222:2004; PB/SBHŚ/02; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12
PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 16266:2009
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03; PN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB/SBiPŚP/02
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
8 lines
ISO/IEC 17025
ActiveAB 634
The scope document we hold says it is valid until 2029-10-09.
Accredited scope, certificate AB 634
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. Zakres akredytacji Nr AB 634
Scope of accreditation No. AB 634
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 634
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 22 z/of 09.09.2025
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 634 z dnia 03.02.2021 r.
Cykl akredytacji od 09.09.2025 r. do 09.10.2029 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 634 of 03.02.2021
Accreditation cycle from 09.09.2025 to 09.10.2029
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 22, 09.09.2025 1/9
Nazwa i adres / Name and address
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA
W STARACHOWICACH
ul. Złota 6
27-200 Starachowice
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/29/P - Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi / Chemical tests and sampling of
drinking water
- C/28
- C/33/P
- Badania chemiczne wody / Chemical tests of water
- Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze) / Chemical
tests and sampling – working environment (harmful factors – air)
- G/33 - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki
szkodliwe i uciążliwe – hałas, drgania, oświetlenie) / Tests concerning environmental engineering
(enviromental and climatic) – working environmental (harmful and nuisance factors – noise, vibration,
lighting)
- K/28
- K/29/P
- Badania mikrobiologiczne wody / Microbiological tests of water
- Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological tests and
sampling of drinking water
- N/28 - Badania właściwości fizycznych wody / Tests of phisical properties and sampling of water,
- N/29/P
- N/33/P
- Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi / Tests of phisical
properties of drinking water
- Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe –
powietrze) / Tests of phisical properties and sampling – working enviroment (harmful factors – air)
- K/3
- Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań /
Microbiological tests of biological items and materials for testing
Wersja strony: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 634 | - |
| 2 | PN-EN 27888:1999; PN-C-04576-4:1994; PN-82/C-04576.08; PN-EN ISO 7027-1:2016-09; PN-ISO 6332:2001 + Ap1:2016-06; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012+ Ap1:2015-06; PN-EN ISO 8467:2001; PN-ISO 6059:1999; PN-92/C-04590/03; PN-ISO 5667-5:2017-10 | Drinking water | See scope document |
| 3 | PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12; PN-EN ISO 19458:2007 | Drinking water | - |
| 4 | PN-EN ISO 7027-1:2016-09; PN-82/C-04576.08; PN-EN ISO 8467:2001; PN-EN ISO 10523:2012; PB/SBHŚ/03; PB/SBHŚ/04; PN-EN ISO 6222:2004; PB/SBHŚ/02; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12 | Pool water | 0.2 to 100 NTU |
| 5 | PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 16266:2009 | Woda z kąpielisk; Płyny dializacyjne | 1 to jtk/100 ml |
| 6 | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03; PN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB/SBiPŚP/02 | Workplace air | 44 to 136 dB |
| 7 | PN-EN ISO 5349-1:2004; PN-EN ISO 5349- 2:2004; PN-EN ISO 5349-2:2004 / A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.2 to 316 m/s2 |
| 8 | PB/SMPiDDD/01 | Kał | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Grupa DALAB Bożek DariuszŁużna · ~149 kmPCAShares 6 accredited methods and materialsEN ISO 9308-1:2014-12PN-N-01307:1994Drinking water
- Centrum Badań i DozoruLędziny · ~171 kmPCAShares 6 accredited methods and materialsEN ISO 6222:2004EN ISO 7027-1:2016-09Drinking water
- MS LAB Spółka z ograniczoną odpowiedzialnościąRypin · ~251 kmPCAShares 6 accredited methods and materialsEN ISO 6222:2004EN ISO 7027-1:2016-09PN-N-01307:1994
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~375 kmPCAShares 6 accredited methods and materialsEN ISO 5349-1:2004EN ISO 7027-1:2016-09PN-N-01307:1994
- TES LABORATORIUM Spółka z ograniczoną odpowiedzialnościąWarszawa · ~125 kmPCAShares 5 accredited methods and materialsEN 27888:1999EN ISO 5349-1:2004PN-N-01307:1994
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.