Registers refreshed 2026-11-20.See refresh dates
Poland

Powiatowa Stacja Sanitarno-Epidemiologiczna w Starachowicach

ul. Złota 6, 27-200, Starachowice, Poland

PCA AB 634ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
25
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 25 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO17
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
Show all 17
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN3
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance

Certificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.

EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards5
C-04576-4:1994
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

8 lines
PCA

ISO/IEC 17025

Active

AB 634

The scope document we hold says it is valid until 2029-10-09.

View on PCA

Accredited scope, certificate AB 634

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Zakres akredytacji Nr AB 634 Scope of accreditation No. AB 634 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 634 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 22 z/of 09.09.2025 p.o. KIEROWNIKA DZIAŁU AKREDYTACJI BADAŃ CHEMICZNYCH MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 634 z dnia 03.02.2021 r. Cykl akredytacji od 09.09.2025 r. do 09.10.2029 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 634 of 03.02.2021 Accreditation cycle from 09.09.2025 to 09.10.2029 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 22, 09.09.2025 1/9 Nazwa i adres / Name and address POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W STARACHOWICACH ul. Złota 6 27-200 Starachowice Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/29/P - Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi / Chemical tests and sampling of drinking water - C/28 - C/33/P - Badania chemiczne wody / Chemical tests of water - Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze) / Chemical tests and sampling – working environment (harmful factors – air) - G/33 - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie) / Tests concerning environmental engineering (enviromental and climatic) – working environmental (harmful and nuisance factors – noise, vibration, lighting) - K/28 - K/29/P - Badania mikrobiologiczne wody / Microbiological tests of water - Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological tests and sampling of drinking water - N/28 - Badania właściwości fizycznych wody / Tests of phisical properties and sampling of water, - N/29/P - N/33/P - Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi / Tests of phisical properties of drinking water - Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze) / Tests of phisical properties and sampling – working enviroment (harmful factors – air) - K/3 - Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań / Microbiological tests of biological items and materials for testing Wersja strony: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 634
-
2PN-EN 27888:1999; PN-C-04576-4:1994; PN-82/C-04576.08; PN-EN ISO 7027-1:2016-09; PN-ISO 6332:2001 + Ap1:2016-06; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012+ Ap1:2015-06; PN-EN ISO 8467:2001; PN-ISO 6059:1999; PN-92/C-04590/03; PN-ISO 5667-5:2017-10Drinking waterSee scope document
3PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12; PN-EN ISO 19458:2007Drinking water-
4PN-EN ISO 7027-1:2016-09; PN-82/C-04576.08; PN-EN ISO 8467:2001; PN-EN ISO 10523:2012; PB/SBHŚ/03; PB/SBHŚ/04; PN-EN ISO 6222:2004; PB/SBHŚ/02; PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08; PN-EN ISO 11731:2017-08 /Ap1:2019-12Pool water0.2 to 100 NTU
5PN-EN ISO 9308-1:2014-12; PN-EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 16266:2009Woda z kąpielisk; Płyny dializacyjne1 to jtk/100 ml
6PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03; PN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB/SBiPŚP/02Workplace air44 to 136 dB
7PN-EN ISO 5349-1:2004; PN-EN ISO 5349- 2:2004; PN-EN ISO 5349-2:2004 / A1:2015-11; PN-EN 14253+A1:2011Workplace environment0.2 to 316 m/s2
8PB/SMPiDDD/01Kał-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Złota 6, Starachowice, 27-200, PL

51.05189, 21.07614

Open in Maps

Accreditation data refreshed from the PCA register on .