FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

K-UTEC AG Salt Technologies Abteilungen chemisch-physikalische Analytik & Geophysik

Am Petersenschacht 7, 99706, Sondershausen, Germany

DAKKS|D-PL-14237-01-00DAKKS|D-PL-14237-01-02DAKKS|D-PL-14237-01-01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
3
Scope items
8
Standards
11
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at K-UTEC AG Salt Technologies Abteilungen chemisch-physikalische Analytik & Geophysik?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-14237-01-00Active
D-PL-14237-01-02Active
D-PL-14237-01-01Active

Accredited standards

11

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 1483Water quality - Determination of mercury - Method using atomic absorption spectrometry
As written on the certificate · Line 3 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02

EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
As written on the certificate · Line 4 (DAKKS D-PL-14237-01-01)

DIN EN 1484 1997-08; DIN EN 13137 2001-12; DIN 38406; DIN 38405; EN 1484

EN 12879Characterization of sludges - Determination of the loss on ignition of dry mass
As written on the certificate · Line 3 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02

EN 12880Characterization of sludges - Determination of dry residue and water content
As written on the certificate · Line 3 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02

EN 13137Characterization of waste - Determination of total organic carbon (TOC) in waste, sludges and sediments
As written on the certificate · Line 4 (DAKKS D-PL-14237-01-01)

DIN EN 1484 1997-08; DIN EN 13137 2001-12; DIN 38406; DIN 38405; EN 1484

EN 13346Characterization of sludges - Determination of trace elements and phosphorus - Aqua regia extraction methods
As written on the certificate · Line 2 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11969 1996-11; DIN EN 13346 2001-04; DIN EN 27888 1993-11; DIN EN 26777 1993-04; DIN 38404

EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
As written on the certificate · Line 2 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11969 1996-11; DIN EN 13346 2001-04; DIN EN 27888 1993-11; DIN EN 26777 1993-04; DIN 38404

EN 27888Water quality - Determination of electrical conductivity
As written on the certificate · Line 2 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11969 1996-11; DIN EN 13346 2001-04; DIN EN 27888 1993-11; DIN EN 26777 1993-04; DIN 38404

ISO

ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
As written on the certificate · Line 3 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02

ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
As written on the certificate · Line 3 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02

ISO 11969Water quality - Determination of arsenic - Atomic absorption spectrometric method (hydride technique)
As written on the certificate · Line 2 (DAKKS D-PL-14237-01-01)

DIN EN ISO 11969 1996-11; DIN EN 13346 2001-04; DIN EN 27888 1993-11; DIN EN 26777 1993-04; DIN 38404

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-14237-01-00

View scope

Accredited scope, certificate D-PL-14237-01-00

LineDisciplineMethodMatrixRange
1-DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-14237-01-02

View scope

Accredited scope, certificate D-PL-14237-01-02

LineDisciplineMethodMatrixRange
1Non-Destructive TestingDIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--
2Electrical TestingDIN 45688; DIN 4150-1; DIN 4150-2; DIN 4150-3--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-14237-01-01

View scope

Accredited scope, certificate D-PL-14237-01-01

LineDisciplineMethodMatrixRange
1Non-Destructive TestingDIN EN ISO/IEC 17025:2018Salzen und Salzlösungen-
2Chemical TestingDIN EN ISO 11969 1996-11; DIN EN 13346 2001-04; DIN EN 27888 1993-11; DIN EN 26777 1993-04; DIN 38404Water-
3Chemical TestingDIN EN ISO 11885 2009-09; DIN EN ISO 10304-1 2009-07; DIN EN 1483 2007-07; DIN EN 12880 2001-02; DIN EN 12879 2001-02Water-
4Chemical TestingDIN EN 1484 1997-08; DIN EN 13137 2001-12; DIN 38406; DIN 38405; EN 1484Water-
5Electrical TestingKALI 97-003/01--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Am Petersenschacht 7, Sondershausen, 99706, DE

51.37120, 10.84739

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.