Kiwa Primara

Gewerbestraße 28-32, 87600, Kaufbeuren, Germany

DAKKS D-PL-12089-01-00DAKKS D-PL-12089-01-01DAKKS D-PL-12089-01-02and 1 moreISO/IEC 17025Register refreshed 2026-11-20
Part of the Kiwa group: 40 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
170
DAKKS certificates
4
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 170 standard numbers and the 38 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC46
IEC 60086
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60255-21-3
IEC 60255-27
IEC 60519-1
IEC 60519-2
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60589-2-4
IEC 60695-2-11
IEC 60695-2-12
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60730-2-7
Show all 46
IEC 60884-1
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 60950-22
IEC 61204-7
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
IEC 61427-1
IEC 61683
IEC 61800-5-1
IEC 61800-5-2
IEC 61851-22
IEC 61851-23
IEC 61960-3
IEC 62031
IEC 62040-1
IEC 62040-3
IEC 62109-1
IEC 62109-2
IEC 62116
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62196-1
IEC 62196-2
IEC 62262
IEC 62281
IEC 62384
IEC 62560
IEC 62619Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62620
IEC 62752
IEC 62955
IEC 63056
IEC 63057Some clauses

Limits written next to it

DIN EN IEC 63057:2020-12 Sekundärzellen und -batterien mit alkalischen oder anderen nicht- säurehaltigen Elektrolyten - Sicherheitsanforderungen für sekundäre Lithium-Batterien zur Verwendung in Straßenfahrzeugen mit Ausnahme des Antriebs Secondary cells and batteries containing alkaline or other no

Some clauses. Written next to it on line 53 of DAKKS certificate D-PL-12089-01-01.

IEC 80601-2-26
IEC 60335 series31
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-6
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
IEC 60335-2-13Household and similar electrical appliances - Safety - Part 2-13: Particular requirements for deep fat fryers, frying pans and similar appliances
IEC 60335-2-15
IEC 60335-2-21
IEC 60335-2-23
IEC 60335-2-24
IEC 60335-2-25
IEC 60335-2-26
IEC 60335-2-30
Show all 31
IEC 60335-2-31
IEC 60335-2-32
IEC 60335-2-36
IEC 60335-2-37
IEC 60335-2-38
IEC 60335-2-39
IEC 60335-2-41
IEC 60335-2-42
IEC 60335-2-45
IEC 60335-2-47
IEC 60335-2-65
IEC 60335-2-70
IEC 60335-2-75
IEC 60335-2-80
IEC 60335-2-81
IEC 60335-2-84
IEC 60335-2-89
IEC 60335-2-98
IEC 60335-2-102
IEC 60068 series14
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-67
IEC 60068-2-68
IEC 60068-2-75Range limit

Limits written next to it

DIN EN 60068 -2-75 2015-08 Umgebungseinflüsse - Teil 2 -75: Prüfungen - Prüfung Eh: Hammerprüfungen Pendelhammerprüfung: nur bis zu 1

Range limit. Written next to it on line 46 of DAKKS certificate D-PL-12089-01-01.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN12
EN 50102
EN 50124-1
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50178
EN 50272-1
EN 50272-2
EN 50491-3
EN 50533
EN 50549-1
EN 50549-2
EN 50564
EN 50604-1
IEC 60601 series12
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-1
IEC 60601-1-4
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-2-2
IEC 60601-2-10
IEC 60601-2-25
IEC 60601-2-26
IEC 60601-2-27
IEC 60601-2-40
IEC 60601-2-46Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
IEC 61557 series9
IEC 61557-1
IEC 61557-2
IEC 61557-3
IEC 61557-4
IEC 61557-5
IEC 61557-6
IEC 61557-7
IEC 61557-8
IEC 61557-9
IEC 61010 series8
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-030
IEC 61010-2-051
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-120
IEC 61010-2-201
ISO8
ISO 6270-1Paints and varnishes - Determination of resistance to humidity - Part 1: Condensation (single-sided exposure)
ISO 6270-2Paints and varnishes - Determination of resistance to humidity - Part 2: Condensation (in-cabinet exposure with heated water reservoir)
ISO 6469-1Electrically propelled road vehicles - Safety specifications - Part 1: Rechargeable energy storage system (RESS)
ISO 6722-2Road vehicles - 60 V and 600 V single-core cables - Part 2: Dimensions, test methods and requirements for aluminium conductor cables
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 12100Safety of machinery - General principles for design - Risk assessment and risk reduction
ISO 12405-4Electrically propelled road vehicles —Test specification for lithium-ion traction battery packs and systems - Part 4: Performance testing
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
IEC 61558 series7
IEC 61558-2-1
IEC 61558-2-4
IEC 61558-2-6
IEC 61558-2-7
IEC 61558-2-13
IEC 61558-2-15
IEC 61558-2-16
IEC 62841 series6
IEC 62841-1
IEC 62841-2-2
IEC 62841-2-8
IEC 62841-2-9
IEC 62841-2-21
IEC 62841-3-4
IEC 60598 series4
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-2-2
IEC 60598-2-4
IEC 60598-2-22
IEC 60664 series4
IEC 60664-1
IEC 60664-3
IEC 60664-4
IEC 60664-5
IEC 61347 series4
IEC 61347-1
IEC 61347-2-7
IEC 61347-2-11
IEC 61347-2-13
IEC 62660 series3
IEC 62660
IEC 62660-2
IEC 62660-3
Other standards2
DIN 57710-14
XP C15-712-3

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

92 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12089-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12089-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12089-01-02

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12089-01-03

View scope

Location

Gewerbestraße 28-32, Kaufbeuren, 87600, DE

47.92127, 10.62807

Open in Maps

Accreditation data refreshed from the DAKKS register on .