FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
China

Shenzhen GUOREN Certification Technology Service Co.,

101#, Building K & Building T, The Second Industrial Zone, Jiazitang Community, Fenghuang Street, Guangming District, Shenzhen, 518132, People's Republic of China, Shenzhen, China

A2LA|6202.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Shenzhen GUOREN Certification Technology Service Co.,?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
6202.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

6202.01

The scope document we hold says it is valid until 2027-04-30.

View scope

Accredited scope, certificate 6202.01

LineDisciplineMethodMatrixRange
1electricalCFR 47 FCC Part 15 Subpart B (using ANSI C63.4:2014); CISPR 32; EN 55032; AS/NZS CISPR 32; ICES-003; CISPR 11; EN 55011; AS/NZS CISPR 11; EN 55014-1; CISPR 14-1; EN IEC 55015; CISPR 15; ICES-001 Issue 5; ICES-003 Issue 7; FCC 47 CFR Part 18 (using MP-5:1986); IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-3; EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-6; KN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11-to 40 GHz
2----
3electricalETSI EN 301 091-3; ETSI EN 301 426; ETSI EN 301 427; ETSI EN 301 428; ETSI EN 301 430; ETSI EN 301 441; ETSI EN 301 442; ETSI EN 301 443; ETSI EN 301 444; ETSI EN 301 447; ETSI EN 301 459; ETSI EN 301 681; ETSI EN 301 682; ETSI EN 301 721; ETSI EN 302 186; ETSI EN 302 340; ETSI EN 301 473; ETSI EN 303 978; ETSI EN 305 550-1; ETSI EN 305 550-2; IEC 62388; ETSI EN 301 360; ETSI EN 302 448; ETSI EN 303 980; Japan MIC Article 2-1 Item (8); MIC Article 2-1 Item (19); MIC Article 2-1 Item (19)-2; MIC Article 2-1 Item (19)-2-2; MIC Article 2-1 Item (19)-2-3; MIC Article 2-1 Item (19)-3; MIC Article 2-1 item 72; AS/NZS 4268; IEEE C95.3; KDB Publication 447498; IEC 62479; IEC 62311; EN 62479; EN 62311; EN 50383; EN 50385; EN 50364; EN 50663; EN 50401; EN 50664; EN 50665; EN 50671; IEC 62368-1; EN 62368-1; AS/NZS 62368.1; UL 62368-1; UL 4200A; EN 61558-1; IEC 61558-1; EN 61558-2-16; IEC 61558-2-16--
4electricalANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.10:2020-to 40000 MHz
5electricalANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); ANSI C63.26-2015; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015-to 260000 MHz
6electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.