United States

Intoximeters

2081 Craig Road, 63146, St. Louis, MO, United States

Visit website
A2LA 3384.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3384.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3384.01) 2/21/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INTOXIMETERS, INC. 2081 Craig Road St. Louis, MO 63146 Elijah Milan Phone: 314 429 4000 CALIBRATION Valid To: March 31, 2027 Certificate Number: 3384.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Chemical Parameter/Equipment Range CMC2 (±) Comments Gas Detection Equipment – Ethanol Concentration (0 to 0.099) g/210 L (0.100 to 0.500) g/210 L 0.002 g/210 L 1.6 % of reading NIST traceable dry gas ethanol standards, g/210 L is by breath or international equivalent II. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Barometric Pressure – Measuring Equipment (550 to 780) mmHg 0.58 % of reading Comparative reference to NIST traceable reference barometer at ambient pressure (740 to 760) mmHg and low pressure (550 to 650) mmHg ____________________ 1 Commercial calibration service is sometimes available for this laboratory.
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3384.01) 2/21/2025 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2081 Craig Road, St. Louis, MO, 63146, US

38.62803, -90.19102

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.