VTEC Laboratories Inc.
212 Manida Street, 10474, Bronx, NY, United States
Visit website- Accredited standards
- 33
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 33 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM23
ASTM C177
ASTM C201
ASTM C518
ASTM C1166
ASTM D229
ASTM D635
ASTM D1929
ASTM D2303
ASTM D2843
ASTM D2863
ASTM D3675
ASTM E119
Show all 23
ASTM E136
ASTM E329
ASTM E648
ASTM E662
ASTM E695
ASTM E736
ASTM E814
ASTM E1317
ASTM E1321
ASTM E1354
ASTM E1513
ISO7
ISO 1182Reaction to fire tests for products - Non-combustibility test
ISO 2719Determination of flash point - Pensky-Martens closed cup method
ISO 5658-2Reaction to fire tests - Spread of flame - Part 2: Lateral spread on building and transport products in vertical configuration
ISO 5659-2Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5660
ISO 9239-1Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source
ISO 15370Ships and marine technology - Low-location lighting (LLL) on passenger ships - Arrangement
Other standards3
FMVSS 302
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
NF X70-100-2
ASTM E119; ASTM E814; UL 263; UL 1709; UL 10 B; UL 10 C; API 607; IEEE 383; IEEE 1202; IEC 60332-1-2; ASTM D3675; E162; ASTM E1317; ASTM E1321; 2010 FTP Annex 1: Part 5; ISO 5658-2; FMVSS 302; ASTM E1354; ISO 5660; AITM 2.0007; AITM 2.0008; AITM 3.0005; ASTM D2843; ASTM E662; BSS 7238; BSS 7239; DS 02-711; DS 02-713; NES 711; NES 713; SMP800C; 2010 FTP Annex 1: Part 2; ISO 5659-2; NF X70-100-2; MIL-DTL-24640B; MIL-DTL-24643C; ASTM C1166; UL 1685; ASTM D2303; ASTM D2863; ASTM C177; ASTM C201; ASTM C518; ASTM D1929; ISO 2719; ASTM E136; ISO 1182
ASTM D635; UL 94; ISO 15370; NFPA 259; NFPA 701; ASTM D229; ASTM E648; ISO 9239-1
ASTM E329
ASTM E736; ASTM E695; ASTM E1513; NYC Building Code BC 1704.11 (2014); NYC Building Code BC 1705.14 (2022); NYC Building Code BC 1704.30 (2014); NYC Building Code BC 10248 (2014); NYC Building Code BC 1705.35 (2022); NYC Building Code BC 1025.8 (2022)
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active2805.01
The scope document we hold says it is valid until 2027-04-30.
Accredited scope, certificate 2805.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E119; ASTM E814; UL 263; UL 1709; UL 10 B; UL 10 C; API 607; IEEE 383; IEEE 1202; IEC 60332-1-2; ASTM D3675; E162; ASTM E1317; ASTM E1321; 2010 FTP Annex 1: Part 5; ISO 5658-2; FMVSS 302; ASTM E1354; ISO 5660; AITM 2.0007; AITM 2.0008; AITM 3.0005; ASTM D2843; ASTM E662; BSS 7238; BSS 7239; DS 02-711; DS 02-713; NES 711; NES 713; SMP800C; 2010 FTP Annex 1: Part 2; ISO 5659-2; NF X70-100-2; MIL-DTL-24640B; MIL-DTL-24643C; ASTM C1166; UL 1685; ASTM D2303; ASTM D2863; ASTM C177; ASTM C201; ASTM C518; ASTM D1929; ISO 2719; ASTM E136; ISO 1182 | Building materials | - |
| 2 | ASTM D635; UL 94; ISO 15370; NFPA 259; NFPA 701; ASTM D229; ASTM E648; ISO 9239-1 | Textile | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the organization’s Thermal Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VTEC LABORATORIES INC.
Bronx, NY
For technical competence in the field of
Thermal Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of test and calibration laboratories. This accreditation
demonstrates technical competence for a defined scope and the operation of a quality management
system (refer to joint ISO-ILAC-IAF Communique dated April 2017).
Presented this 27th day of August 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2805.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17020
Active2805.02
The scope document we hold says it is valid until 2027-04-30.
Accredited scope, certificate 2805.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E329 | cement board; concrete; deck; joist; gypsum board | - |
| 2 | VTEC Procedure IP-005; VTEC Procedure IP-001; VTEC Procedure IP-002; VTEC Procedure IP-004 | Gypsum Board; Gypsum/Type Boards; Metal Joist; Metal structural angles; structural rebars; Metal Studs; Wall boards; Insulation | - |
| 3 | ASTM E736; ASTM E695; ASTM E1513; NYC Building Code BC 1704.11 (2014); NYC Building Code BC 1705.14 (2022); NYC Building Code BC 1704.30 (2014); NYC Building Code BC 10248 (2014); NYC Building Code BC 1705.35 (2022); NYC Building Code BC 1025.8 (2022) | Sprayed Fire-resistant Materials and Mastic and Intumescent Fire-resistant Coatings (Paint and Coating Inspection); Photoluminescent signs (running man, exit signs or directional signs) used in Buildings for providing safety information in less than adequately illuminated hallways, stairwells, and doorways; Fabrication of Photoluminescent type signs for walls and stairs | - |
| 4 | ISO/IEC 17020:2012 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ICC Evaluation ServiceElkhart, IN · ~1,017 kmA2LAShares 2 accredited methods and materialsASTM E329Building materials
- Architectural Testing, Inc. (An Intertek Company)- FridleyFRIDLEY, MN · ~1,641 kmA2LAShares 2 accredited methods and materialsASTM E329Building materials
- HRF ServicesEAST ELMHURST, NY · ~10 kmA2LAShares 1 accredited test methodASTM E329
- McHenery Testing Lab, Inc.Douglaston, NY · ~14 kmA2LAShares 1 accredited test methodASTM E329
- Vartest Laboratories, Inc.New York, NY · ~18 kmA2LAShares 1 accredited materialTextile
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.