What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 2383.04 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2383.04) 12/09/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
Q-LAB DEUTSCHLAND GMBH
In Den Hallen 30
D-66115 Saarbrucken, GERMANY
Andreas Giehl Phone: +49-681857470
CALIBRATION
Valid To: March 31, 2028 Certificate Number: 2383.04
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Optical Radiation
Parameter/Equipment
Range
CMC2 (±)
Comments
Irradiance and Radiometers
(0.001 to 2000) W/m2
@ (250 to 800) nm
6.5 % of reading
For UV and visible
light sensors used in
weathering devices
such as xenon arc and
fluorescent UV
Control Parameters in
Weathering
Instruments3, 4 –
Temperature
Relative Humidity
Irradiance
(0 to 100) °C
(10 to 95) % RH
(0.001 to 2000) W/m2
@ (250 to 800) nm
0.25 °C
3.4 % RH
6.8 % of reading
As used in artificial
weathering instruments
Digital thermometer
Rotronic hygropalm
Working radiometer
Control Parameters in a
MTG (Gravelometer)3, 4 –
Air Pressure
Dimension
(10 to 100) psi
(0.261 to 0.284) in
2.1 psi
0.0002 in
Only as used in a MTG
(Gravelometer)
Pressure monitor
Go/No-Go plug gages
____________________________________________
1 This laboratory offers commercial calibration service and field calibration services. | 0.001 to 2000 W/m2 |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2383.04) 12/09/2025 Page 2 of 2
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and
Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level
of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This includes but is not limited to all Q-Lab Corporation Products MTG, fluorescent UV and Xenon-arc
testers.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
In Den Hallen 30, D-66115 Saarbrucken, Germany, D-66115 Saarbrucken, DE
49.27653, 6.95260
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.